Household Mini Leakage Circuit Breaker 60amp 2P 50Hz/60HZ Overload Protection Please contact us for further information!
1P Miniature Electric DC Circuit Breaker 60A Single Phase Main Circuit Breaker Please contact us for further information!
SH201L min circuit breaker mcb switch is applicable to electric circuits with rated voltage 230/400V AC, frequency 50/60Hz and rated current up to 63Amp. The product provides protection against over-load and short circuit to electric circuits and equipment in household and commercial installation. MCB is also used as non-frequent changeover of electric circuits.
C60 DPN mcb thermal magnetic circuit breaker is applicable to protect line conductor and overload,and short circuit of small sealed motors.It is mainly for protection of circuits with AC 220V and 50Hz/60Hz,and for unfrequent conversion under normal conditions as well.Its action can be up to two poles with its only one pole volume and be used as a leakage breaker by assembling with leakage.It is produced as per EN898-87,IEC947-2 standards.
Circuit breaker, switches, moudel case circuit breaker, accontactor, waterproof socket and plugs, solar inverter.
Miniature Circuit Breaker Automatic Assembly and inspecting line MCB Automatic Assembly and inspecting line Keyword: Miniature Circuit Breaker Automatic Assembly, Miniature Circuit Breaker, Automatic Assembly line, Assembly Machine, Assembly Production Line Product Introduction Basic operation process: ï?¼Loading by AGV robots, printing QR codes based on the product work order issued by the SAP system, and then separating the upper and lower shells. ï?¼Bottom coating of the upper shell: The installation of three components is completed through ten processes, and after each assembly is completed, there is a corresponding installation accuracy testing process to ensure that the assembly is completely qualified. ï?¼Installation of lower shell components, upper and lower shell assembly: A total of 25 processes are used to install 12 components. After each part is assembled, guide pins are used to ensure the upper and lower assembly. After the installation of internal components is completed, the product's on/off function is tested. After passing the test, rivets are installed, pressed again, and the screws are removed. All installations are checked, and after passing the test, they are transferred to the inspection station. ï?¼Unipolar products undergo instantaneous detection, delay detection, cooling tower and other unit inspections, and are then labeled with QR codes and covers before being transferred to the next workstation. ï?¼Multi pole products require 9 steps of multi pole assembly, and after assembly, a second delay is performed to verify the stability and reliability of the product ï?¼Finally, it is transferred to the automatic packaging unit through pressure resistance testing, transfer printing, laser labeling, and buckle installation. The specific parameters: (1) Equipment input voltage: 220V �± 10%, 50Hz; (2) The equipment has functions such as automatic shell loading, lid opening, assembly of arc extinguishing plates, magnetic guide plates, handle springs, base springs, positioning pins, handles, jump buckles, locks, coil components, iron core components, wiring columns, adjustment screws, arc extinguishing covers, CCD recognition, lid closing, identification of qualified and unqualified products, assembly of cutting processes, online detection, real-time monitoring, component life monitoring, data storage, MES system and ERP system networking, parameter arbitrary formula, smart energy analysis and energy-saving management system, intelligent equipment service big data cloud platform, etc. (3) Theoretical production effeciency: 2 seconds per unit; Daily production of approximately 14400 pieces/8 hours; (4) This device has the function of power-off to save data for 30 days, making it easy to manage production data; (5) This device adopts touch screen operation, has a computer communication interface, and printing function
Photocells Fans & ventilation, Hazardous area lighting Industrial plugs & sockets Industrial & commercial Lamps Light fittings: fluorescent, weatherproof & floodlighting Refrigeration & air conditioning spares Water heating elements Wiring accessories MCB's Circuit breaker Vacuum Breakers Control transformers Fuses & load break devices Hazardous area products Industrial beacons Industrial sounders, buzzers Industrial surge protection Safety switches Clamp meters Multi-meters Testers Semiconductors: thyristors, rectifiers Pressure switches Solenoid & pilot valves Photoelectric Sensors
3 pole thermal overload bkn circuit breaker mcb is used in lighting distribution system or motor distribution system for protection overload and short-circuit in the system. It has high breaking capacity, can trip quickly, and its case and items are adopted by high fire-resistant and shockproof plastics. The product, with long life, is mainly used in AC 50Hz/60Hz single pole 230V or two, three, four poles 400V circuit for overload and short-circuit protection as well as for infrequent on and off switching electric equipment and lighting circuit in normal case.
S280 3 phase ac power circuit breaker is mainly used for special occasions where two main circuits can not work at the same time. To prevent the simultaneous closing of the circuit breaker, the product can switch the line safely and quickly. It realize the switching between stand-by power supply circuits and other protection functions. Iiâ??s mainly used in the overload protection and short-circuit protection of the circuit which is DC 50Hz/60Hz, 1 pole230v, 2/3/4 poles DC1000V.
PLC, DCS, pressure transmitter, inverter, encoder, human machine interface (HMI), sensor, relay , circuit breaker, servo system.
ABB MCB System pro M compact S200M miniature circuit breakers are current limiting. Theyhave two different tripping mechanisms, the delayed thermal tripping mechanism foroverload protection and the electromechanic tripping mechanism for short circuitprotection. They are available in different characteristics (B,C,D,K,Z), configurations(1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 10 kA at 230/400 V AC) and ratedcurrents (up to 63A). All MCBs of the product range S200M comply with IEC/EN 60898-1 and IEC/EN 609 47-2, allowing the use for residential, commercial and industrialapplications. Bottom-fitting auxiliary contact can be mounted on S200M to save 50%
BRAND : SCHNEIDER MCB 6A - 32A Single Pole Schneider Miniature Circuit Breaker. Product Specification No.of poles 1-4 Pole Rated current 6 to 63 A Voltage 240-415 V Breaking Capacity 10 kA Frequency 50 Hz Curve Type B and C tripping curves Brand Schneider
LV power air circuit-breakers and switch-disconnectors Masterpact Merlin Gerin Masterpact circuit breakers are used to protect and control low-voltage distribution systems. They may be installed in main LV switchboards (incoming units, main and secondary outgoers). Masterpact is a complete range offering a large selection of performance levels: c ratings from 800 to 6300 A AC, from 1000 to 8000 A DC; c breaking capacity from 40 to 150 kA rms; c operational voltages 690 V AC, 1000 V DC.
MCB 6A - 32A 1Pole Make: LS, Korea. 12.
Low voltage & high voltage fuses, DC fuses, DC spd, DC breaker, solar connector, solar cable, circuit breaker.
What is MCCB. MCCB stands for Molded Case Circuit Breaker. It is another type of electrical protection device which is used when load current exceeds the limit of a miniature circuit breaker. The MCCB provides protection against overload, short circuit faults and is also used for switching the circuits.
Terasaki, , square d, siemens, merlin gerin, qo, areva, sylvania, westinghouse, ge, murray, moeller, federal, schneider, zinsco, eta, cutler hammer, airpax, heinemann, klixon, hager. Miniature circuit breaker, air circuit breaker, electric circuit breaker, earth leakage circuit breaker, thermal magnetic circuit breaker, low voltage circuit breaker, molded case circuit breaker, vacuum circuit breaker, standard circuit breaker
Mini circuit breaker Gkd-65 midget circuit breaker is mainly suitable for overload and short circuit of Distribute circuit and equipment within the circuit of ac50hz, rated voltage up to 400v, Current up to 63a. It can also be used for an unfrequent switchover of the circuit. Main technical parameter: 1. Feature of over current tripper 2. When the ambient temperature is 30¦--35¦, the over-current tripper feature should In line with the characteristic of table 1. 3. Breaking capacity: complies with standard of ie60898, gb10963 and gb 10000a.
Mini circuit breaker(dpn) Gkd-32 is mainly suitable for overload and short circuit protection Within the circuit of ac 50/60 hz, rated voltage of single pole 250v or down The item is the idealest distribution protective switch in the civil residence field At present. This product conforms to the requirement of iec60898 and gb10963 standard.
6A,10A,16A,20A,25A,32A,40A,50A,63A 1P,2P,3P