ECG cable, EKG cable, spo2 sensor, Nibp cuff, temperature probe, ESU pencil, ecg electrode, IBP cable.
1.Product Description ECG (electrocardiography) is a method of collecting electrical signals generated by the heart. This allows us to understand the level of physiological arousal that someone is experiencing, but it can also be used to better understand someones psychological state. 2.Product Details Properties: Medical Materials & Accessories Brand Name:GE Cable material: TPU cable Cable Leadwires: 3 leads/5 leads Standard: AHA/IEC Certificate: CE, ISO Other Service: OEM&ODM Sample: Available MOQ: 1pc Warranty:6 months Supply Ability: 1000 Piece/Pieces per Week 3.Shipping and Packing Port:Shenzhen port, or as you need Shipping: DHL/FedEx/EMS/UPS/TNT Packaging Details: Wrap with transparent PU plastic bag, each bag with 1 piece. 4.Payment Terms Payment Terms:L/C,D/A,D/P,T/T,Western Union,Money Gram 5.Main Products We Supply Reusable/ Disposable Spo2 Sensor Spo2 Extension Cable ECG/ EKG Cable with leadwires ECG /EKG Trunk Cable Temperature Probe Fetal & TOCO Transducer IBP Cable and Transducer NIBP Cuff and hose 6.Our Services: More competitive factory price. Fast delivery (1-5 days, we are a manufacturer, have enough products in stock.) Quality 100% assured (All products are made of medical TPU material) Samples available (accept trail order) One piece MOQ is acceptable. OEM & ODM service
ECG: 12-lead resting PC-ECG with auto interpretation VCG: Vector-cardiograph with auto interpretation Hardware Features: High sampling rate of 1000Hz Digital filter system Applying anti-baseline-drift technology ensuring the stability of ECG baseline Wilson and Frank hookup system Meet the international standard of IEC60601-1 Easy operation and perfect printout Diagnosis of coronary heart disease Perfect time domain, frequency domain and non-linear HRV analysis Perfect ECG database management system Specification for PC-ECG: Sample rate: 1000Hz, simultaneous 12 leads recording Resolution:12bit Power: 5.0V (DC) Patient Insulation: 4000V AC Defibrillation Protection: Built-in box Digital resolution: 2V Frequency response: 0.05-250 Hz Common mode rejection: >90dB Input impedance: >10MΩ Time constant: 3.2 s Max electrode potential: ±300mV DC Dynamic range: ±10mV Isolate voltage: 4000V Current leak:
ECG gel, also known as electrocardiogram gel or EKG gel, is a conductive medium used in electrocardiography (ECG) procedures to improve the quality of electrical signal transmission between the skin and the electrodes of the ECG machine. Here's more information about ECG gel: Purpose: The primary purpose of ECG gel is to enhance the conductivity and reduce impedance between the skin and the ECG electrodes. This improves the quality and accuracy of the electrical signals detected by the electrodes, resulting in clearer and more reliable ECG readings. Composition: ECG gel is typically a water-based, conductive gel formulated to be non-greasy, non-staining, and hypoallergenic. It may contain ingredients such as water, glycerin, propylene glycol, carbomer, preservatives, and conductivity-enhancing agents. Conductivity: ECG gel is formulated to have high electrical conductivity, allowing it to effectively transmit electrical signals between the skin and the electrodes. This conductivity helps minimize impedance and artifacts, ensuring accurate ECG readings even in challenging conditions. Viscosity: ECG gel is usually designed to have a suitable viscosity that allows for easy application and smooth spreading on the skin. It should be thick enough to stay in place during the procedure but not so thick that it hinders electrode placement or skin contact. Compatibility: ECG gel is compatible with various types of ECG electrodes, including disposable electrodes, reusable electrodes, and adhesive electrodes. It can be used with both standard ECG procedures and specialized cardiac tests such as stress tests, Holter monitoring, and echocardiography. Application: ECG gel is applied directly to the skin at the electrode sites before attaching the electrodes. A sufficient amount of gel should be applied to ensure good contact between the electrodes and the skin surface. Excess gel can be wiped away after electrode placement. Hygiene: ECG gel should be stored in a clean and dry environment to prevent contamination. Disposable single-use packets or bottles with dispensing caps are commonly used to maintain hygiene and prevent cross-contamination between patients. Removal: After the ECG procedure, any remaining gel should be wiped off the skin using a clean, dry cloth or disposable wipe. Residual gel left on the skin can cause discomfort or irritation if not properly removed.
Leads:12 Channel Sample Rate:10240Hz Anti-Interference Compatible with Win xp,7,8,10 Support Stress and Resting ECG Testing USB Power Supply
An ECG bulb, made of silicone, is a component used in certain types of electrocardiogram (ECG) machines. Here's more information about ECG bulbs made of silicone: Material: ECG bulbs made of silicone are designed to be flexible, durable, and resistant to wear and tear. Silicone is chosen for its properties, including flexibility, biocompatibility, and resistance to temperature extremes and chemical exposure. Purpose: The ECG bulb, also known as an ECG electrode or sensor, is a crucial component of the ECG machine. It serves as the interface between the patient's skin and the machine's electrical circuitry, allowing the machine to detect and record the electrical signals produced by the heart. Design: ECG bulbs made of silicone typically have a bulbous or rounded shape with a flat surface that comes into contact with the patient's skin. The silicone material provides a comfortable and secure fit while ensuring good electrical conductivity for accurate signal transmission. Compatibility: Silicone ECG bulbs are designed to be compatible with specific models of ECG machines. They may come in different sizes and shapes to accommodate different electrode configurations and patient needs. Hygiene: Silicone ECG bulbs are often designed for single-use or disposable use to maintain hygiene and prevent cross-contamination between patients. Disposable ECG bulbs help reduce the risk of infection transmission in clinical settings.
Disposable ECG electrodes.
High-conductivity gel for electrocardiography (ECG) is a specialized conductive gel used to improve electrical conductivity between the skin and ECG electrodes during cardiac monitoring procedures. Here's more information about high-conductivity gel for ECG: Purpose: The primary purpose of high-conductivity gel is to reduce impedance and improve the transmission of electrical signals between the skin and the ECG electrodes. This ensures accurate and reliable recording of the heart's electrical activity during ECG testing. Composition: High-conductivity gel is typically water-based and contains conductive agents that enhance its electrical conductivity properties. Common ingredients may include water, glycerin, propylene glycol, carbomer, electrolytes (e.g., sodium chloride), and preservatives. Conductivity: High-conductivity gel is formulated to have superior electrical conductivity compared to standard ECG gels or other electrode contact solutions. This allows for better signal quality and minimizes the risk of artifacts or interference during ECG recordings. Viscosity: The gel's viscosity is designed to be suitable for easy application and spreadability on the skin. It should be thick enough to adhere to the skin and maintain contact with the electrodes but not too thick that it hinders electrode placement or skin contact. Non-Staining: High-conductivity gel is typically formulated to be non-greasy and non-staining, ensuring minimal residue on the skin after use. This helps maintain patient comfort and prevents staining of clothing or bedding. Compatibility: High-conductivity gel is compatible with various types of ECG electrodes, including disposable electrodes, reusable electrodes, and adhesive electrodes. It can be used with standard ECG machines and Holter monitors. Application: Before applying the gel, the skin should be cleaned to remove any oils, lotions, or dirt that may interfere with electrode contact. A thin layer of high-conductivity gel is then applied to the skin at the electrode sites before attaching the electrodes. Hygiene: High-conductivity gel should be stored in a clean and dry environment to prevent contamination. Disposable single-use packets or bottles with dispensing caps are commonly used to maintain hygiene and prevent cross-contamination between patients. Overall, high-conductivity gel plays a crucial role in ensuring optimal electrode-skin contact and signal quality during ECG testing. Its superior conductivity properties make it an essential accessory in cardiac diagnostic procedures, allowing for accurate interpretation of the heart's electrical activity.
ECG holter analysis system, resting ECG system, stress test ECG, telemetry ECG monitoring system, holter recorder, ambulatory blood pressure monitor, mobile ECG, fingertip pulse oximeter, multi-parameter patient monitor, fetal doppler, computerized ecg simulator, ECG parts and accessories.
12-lead simultaneous standard resting ECG 7-inch TFT, touch screen, led backlight Digital isolation technology and signal processing solution, digital filter Patient management, name and age and id. Detail analysis report. Multi-language options: Germany, France, Italian, Turkey, etc Built-in lithium rechargeable battery, wide thermal printing system USB and LAN socket Memory: Built-in memory or mini SD Memory card. Store more than 1000 pieces of archive Auto-measurement, auto-analysis, and auto-interpretation
ECG products, holter ECG, resting ECG, stress test ECG, ambulatory blood pressure monitor, ECG simulator, patient monitor.
High quality patient monitoring and medical surgical consumables , ecg electrodes, defibrillator pads, medical chart papers & patient monitoring, grounding pads, ultrasound gels, video films and accessories, endotube (endoscopy disposable tubing), claravue electrodes 5 day wear, face shields and filters, cables and leadwires..Manufacture and distribute
Medical equipment, medical device, cardiology (resting ECG machine, holter ECG monitor, holter blood pressure monitor, stress testing system, defibrillator, aed, spirometer), patient monitoring (multi parameter patient monitor, vital sign monitor, handheld pulse oximeter, fingertip pulse oximeter, blood pressure monitor), home healthcare (fetal doppler, thermometer, infrared thermometer, glucometer, oxygen concentrator), disposable & consumable ( ECG recording paper, ctg recording paper, biochemistry analyzer recording paper, patient monitor recording paper, spirometer recording paper, ultrasound recording paper, ECG gel, ultrasound gel, disposable ECG electrode, disposable tnt electrode, disposable ESU electrode, disposable holter ECG electrode, NIBP cuff, spo2 probe, spo2 sensor, ECG cable for patient monitor, patient cable for ECG machine, limb electrode for ECG machine, chest electrode for ECG machine, syringe, surgical blade).
ECG paper for the 6108T machine is a specific type of paper used for recording electrocardiogram (ECG) tracings produced by the 6108T ECG machine. Here's more information about ECG paper for the 6108T machine: Size: The ECG paper is typically sized at 50 millimeters (mm) in width and 20 meters (m) in length. This size is compatible with the 6108T ECG machine and allows for the recording of ECG tracings with standard parameters. Composition: ECG paper is usually made of high-quality paper stock that is heat-sensitive. It is coated with a special layer of chemicals that react to the heat generated by the ECG machine's thermal printer, producing a permanent record of the ECG tracing. Grid: The ECG paper typically features a grid pattern printed on the surface, which helps healthcare professionals interpret the ECG tracings accurately. The grid consists of horizontal and vertical lines that represent time and voltage measurements, respectively. Compatibility: ECG paper for the 6108T machine is specifically designed to be compatible with the 6108T ECG machine model. It is calibrated to ensure accurate printing and clear visualization of ECG waveforms. Packaging: ECG paper for the 6108T machine is commonly sold in rolls, with each roll containing a specified length of paper. The rolls are typically packaged in boxes or cartons for protection during storage and transportation. Usage: To use the ECG paper with the 6108T machine, the roll is loaded into the thermal printer mechanism of the machine. When an ECG recording is initiated, the machine generates electrical signals that are converted into heat by the thermal printhead, causing the ECG waveforms to be printed onto the paper. Recording: The ECG paper is designed to produce high-quality, clear, and accurate recordings of ECG waveforms. The printed tracings include the P waves, QRS complexes, T waves, and other relevant features of the cardiac cycle, allowing healthcare providers to assess the patient's cardiac rhythm and function. Overall, ECG paper for the 6108T machine is an essential consumable item used in cardiac diagnostic procedures. It plays a crucial role in producing accurate and reliable recordings of ECG tracings for interpretation by healthcare professionals.
ECG paper compatible with Schiller AT, AT-2, and AT-2 Plus machines is a specific type of paper used for recording electrocardiogram (ECG) tracings produced by these particular ECG machines manufactured by Schiller AG. Here's more information about ECG paper for Schiller AT, AT-2, and AT-2 Plus machines: Size: The ECG paper for Schiller AT, AT-2, and AT-2 Plus machines typically comes in rolls with a standardized width and length. The dimensions are specifically designed to fit the printing mechanisms of these machines, ensuring compatibility and accurate printing of ECG tracings. Composition: ECG paper for Schiller machines is usually made of high-quality thermal paper stock. This paper is heat-sensitive and coated with a chemical layer that reacts to the heat generated by the ECG machine's thermal printer, resulting in the production of clear and permanent ECG tracings. Grid: The ECG paper often features a grid pattern printed on the surface, which aids in the interpretation of ECG tracings by healthcare professionals. The grid consists of horizontal and vertical lines that represent time and voltage measurements, respectively, allowing for accurate analysis of the ECG waveforms. Compatibility: ECG paper for Schiller AT, AT-2, and AT-2 Plus machines is specifically designed and calibrated to be compatible with the printing mechanisms and recording specifications of these ECG machine models. It ensures accurate and reliable printing of ECG tracings without distortion or inaccuracies. Packaging: ECG paper for Schiller machines is commonly packaged in rolls, with each roll containing a certain length of paper. The rolls are typically packaged in boxes or cartons for protection during storage and transportation. Usage: To use the ECG paper with Schiller AT, AT-2, or AT-2 Plus machines, the roll is loaded into the thermal printer mechanism of the machine. When an ECG recording is initiated, the machine generates electrical signals that are converted into heat by the thermal printhead, causing the ECG waveforms to be printed onto the paper. Recording: The ECG paper produces high-quality, clear, and accurate recordings of ECG waveforms. The printed tracings include the P waves, QRS complexes, T waves, and other relevant features of the cardiac cycle, allowing healthcare providers to assess the patient's cardiac rhythm and function accurately. Overall, ECG paper for Schiller AT, AT-2, and AT-2 Plus machines is an essential consumable item used in cardiac diagnostic procedures. It ensures the production of accurate and reliable recordings of ECG tracings for interpretation by healthcare professionals.
Medical disposable sensors ecg, ekg electrode, tab electrode, bovie plate, tens, ems electrode, spo2 sensors, pulse oxymeter, neonatal ecg, defibration pad.
Orthopedic appliances, compression stockings, sports supports, bandages, surgical dressings, ECG electrodes, rehabilitation aids, tractions, incontinence pads.
Ecg, ultra sound & eeg jelly, medical chart papers, thermal rolls, ecg electrodes different types, xray chemicals including developer &fixer with hardner, herbal white phenyl & its concentrate, glove powder.
Disposable SPO2 sensor, reusable SPO2 sensor, SPO2 extension cable, patient monitor cable and lead wires, ECG/EKG cable and electrodes, temperature probe, NIBP cuff and extension hose, IBP cable and disposable transducer.
Medical electronic equipment, reusable spo2 sensors, disposable spo2 sensors, spo2 extension cables, patient monitor ecg cables, EKG cables, ECG, electrodes, holter cables, ECG lead wires, electrosurgical supplies, ibp cables, ibp transducers, temperature probes, nibp cuffs, fetal transducers, fetal probes, ultrasound transducers, ultrasound probes.