Ecg workstation gl8000 Specification: 1. Sample rate: 1000Hz, simultaneous 12 leads recording 2. Resolution:12bit 3. Power: 5.0V (DC) 4. Patient Insulation: 4000V AC 5. Defibrillation Protection: Built-in box 6. Digital resolution: 2 V 7. Frequency response: 0.05-250 Hz 8. Common mode rejection: >90dB 9. Input impedance: >10M 10. Time constant: í¦3.2 s 11. Max electrode potential: í+300mV DC 12. Dynamic range: í+10mV 13. Isolate voltage: 4000V 14. Current leak:
Features: Simultaneous acquisition of 12-lead ecg data, 12 leads waveform display and print by segment 9 inch color high resolution lcd screen, color graphics menu, convenient and intuitive man- machine dialogue Touch screen control, easy to operate it Manual\auto 3ch+3r, 6ch, 6ch+1r, 12ch, 12+1r and 60 sec arrhythmia waveform analysis , 5 minutes arrhythmia analysis. 1000 ecg data storage, sd card support Alarm of electrodes breaking off, body diagram indicates the unconnected lead V1, v3, v5 chest lead examination mode, easy operation. Recording one case ecg data in 3 seconds, and useful for the large-scale examination. Box
Biocompatibility: all patient contact materials are latex free and have been tested About us: 1)high quality and competitive price; 2)standard packing and timely delivery; 3)we supply oem service; 4)sample order and small order are acceptable; 5)the terms of payment: t/t , paypal; 6)the methods of delivery: dhl, ems, ups or fedex (fast and safer); 7)all products are shifting one-year warranty and three months guarantee for replacement; 8)we are a processional manufacturer in mainland china, we have various brands of spo2 sensor, ecg cable and lead wire, ekg cable and lead wire, nibp cuff, ibp cable, temperature probe, holter cable and lead wire, etc; 9)we have ce and iso certificate. We also produce the following items Reusable spo2 sensor Disposable spo2 sensor Spo2 extension cable Ecg cable with leadwires Ekg cable with leadwires, ekg /ecg trunk cable Temperature probe Fetal transducer Ecg electrode Eeg cable Plastic bag with outer carton to protect
10k series reusable skin temperature probes Specifications 1.3m/10ft, 2.252k resistance 2.12mm disk, 6.3mm mono plug 3.Excellent thermal cycle endurance 4.Stable performance 5.Ce&iso Features: 1.Fast thermal response time constant: 3.5sec max in still air 2.Stable stability and good bio-compatibility 3.High accuracy: tolerance up to ¡¨¤0.02¡ãc 4.Excellent thermal cycle endurance 5.Ce&iso13485 met 6.One year warranty Application: 1.Skine / coelom / body temperature measurement 2.Esophageal / rectal / air / skin chemical sterilisation 3.Disposal or reusable temperature probe for medical application We also produce the following items: Reusable spo2 sensor Disposable spo2 sensor Spo2 extension cable Ecg cable with leadwires Ekg cable with leadwires, ekg /ecg trunk cable Temperature probe Fetal transducer Ecg electrode Eeg cable Ibp cable and transducer Nibp cuff and hose Esu electrosurgical pencil Wire harness Plastic bag with outer carton
Mini Holter recorders 3 to 12 leads, 4 to 10 electrodes, recordings up to 8 days, sampling rates of 1024 to 4096 S/s, Phone ECG Transmission of symptomatic and asymptomatic ECG events. Easy Editing of multi-day recordings into one editing file with possibility of printing one report for all days or one report a day Holter analysis of arrythmias (VEs, SVEs, Bigeminy, Trigeminy, Pairs, Runs, V-Tach, Min HR, Max HR), ST, Pauses, QT/QTc, Bundle Branch Blocks. 24h ECG full disclosure scanning with colour coded events for immediate visual verification. 24h Histograms of HR, ST, QT/QTC, VE, SVE, Pauses, and SDNN. Patient Event Monitoring with 3 or 12-Lead ECG strips print outs (XYZ). QT/QTc Analysis Validation Program Atrial Fibrillation / Flutter Detection and Editing menu Time Domain and Spectral Heart Rate Variability 3/12-Lead ST Analysis with 3D graph and FCGCADgram (CAD location Graph) Late Potentials SAECG, VectorCardioGraphy Holter Analysis of Pacemaker Recordings Sleep Apnea Monitoring with detection of SAS episodes T-Wave Alternans analysis (T-Wave Alternans) Satellite Holter Program for Remote scanning of Holter ECG Recordings Customized Reports with custom conclusions format and Header Logo Functions ¡®E-mail, ¡°PDF Output¡±, ¡®ASCII Output, Export, Dicom and HL7 interfaces Windows 72000, NT, XP, Vista compatible. Dimension: 22cm*16cm*8cm Weight: 1kg/set.
Features£º With auto-interpretation function can assist doctor to diagnose Color lcd makes the images more clear for guaranteeing the reliability of the images Designed with technology of digital signal processing and digital isolation Synchronously 12 lead acquisition and printing 3 live leads record of them, using high resolution thermal roll paper for recording ecg waveform, multiple optional digital filter ( including baseline drift filter ), using auto-regulation baseline drift filter which can inhibit any baseline drift , or curb caused by patient's movement and auto- optimize the position for printing Auto measurement / analysis system shows the real-time heart rate which makes it easier for Doctor's diagnosis Can store maximum of 100 patients' ecg data and enable user to replay data analyze and print it From database High-speed usb interface and traditional rs-232 interface are both built¨cin for communicating With computer as well as other devices Data can be received through one of the interfaces and displayed by the software which is also Provided by our company (optional) Specifications: Lcd display: 640¡á480 tft 5.7 inch graphic lcd Lead: standard 12 leads Sampling method: 12 leads synchronously acquisition Cmrr: >80db, > 100db (with ac filter) Sensitivity: auto2.5 5 10 20 mm / mv Paper speed: 6.25 12.5 25 50 mm / s( ¡à 3%) Paper size: 80mm x 30m roll type Recording mode: thermal array printing Power supply: ac: 110-230v (¡à10%) , 50/60 hz¡à1hz 40 va Dc: 14.4v rechargeable li-ion battery Package collocation: Single unit size: 42cm x 26cm x 30cm gross weight: 7 kg 4 pcs/carton dimension : 42cm x 52cm x 60cm gross weight: 27kg Normal collocation: roll paper, patient cable, power cable, limb electrode (limbnip) 4 pcs, chest Electrode ( sucking ball ) 6 pcs, ac electric fuse 2 purchase.
Analyzing software features 1. Multi-windows operation 2. 46 different types arrhythmia analysis 3. Demix morphologies 4. Check sinus node recovery time 5. Check parasystole 6. Check accelerate escape rhythm 7. Check reciprocal beat 8. T wave alterans 9. Heart rate variability 10. Hrt (heart rate turbulence) 11. Sleep apnea analysis 12. Intellectual analysis of various tachycardia 13. Display start and end point of arrhythmia on same screen 14. Beat to beat analysis, no missing beats 15. 26 types histogram analysis 16. Pacemaker analysis can label 7 types shapes 17. St-t analysis Recorder features *1.77 inch color lcd, displays three leads ecg for each screen *high resolution make it is convenient to observe p or q wave and other micro-signal. Lcd screen display ecg grid to facilitate physician to watch ecg waves, count hr and other parameter *skin resistance measurement can evaluate the connection between electrode and patient skin *can freeze the ecg strip in the screen to observe it in detail *battery estimate in case of non-record by low power *holter information browser to display the start time and duration of current recording *speed: 25mm/s, gain: 5mm/mv for lcd screen display *no operation within two minutes, the screen will be auto-off to save power. And button can be locked automatically in case of misoperation *event button can make mark for symptom *the cable socket is mis-plug and break-off proof design. Recorder specification A) holter recorder power: dc 3.0v; B) recording time: 24 hours; C) recording mode: continuous; D) sample rate: 4000hz; E) standard sensitivity: 10mm/mv (-5%, +5%); F) input circuit current: ín0.1ª8a; G) input impedance: >=2.5 m? ; H) noise electric level:
Xinhong carbon advantage: Strictly control of raw material ensures it is from the best origin; Advanced production technology & facilities &experienced workers; Strict quality tracing system to ensure each ge excels buyer needs; Technical assistance & after service are available whenever needed; Sufficient stock in factory to ensure competitive price&fast delivery; Graphite electrodes Graphite electrode is made of petroleum coke, needle coke, and bonding coal pitch. Its production process is: calcining, dosing, mixing, forming, baking and impregnation, graphitization in a high temperature of over 3000c, then precision machining. Graphite electrode is acting as a conductive body which release heat in the form of arc for heating and melting steel in the furnace.According to the application, it can be divided into regular power(rp), high power(hp) and ultra high power(uhp). Graphite electrode is an important conductive material in smelting industry with good electrical conductivity, thermal conductivity and high mechanical strength, good corrosion resistance under high temperature. Graphite electrode is widely used in eaf, lrf, submerged arc furnace(producing ferroalloy, pure silicon, yellow phosphorus, calcium carbide etc), resistance furnace (such as the graphitization furnace, glass melting furnace and silicon carbide furnace etc). Packed in wooden crate or as your requirment.
Electrode, ECG, 42mmx50mm, Adult, Foam, Solid Gel 1. Fair average qualiy assured; 2. Comfortable and conveniet; 3. No gel left and non-irritable; 4. Single use only; 5. Recommended for ICU/CCU, Surgery, Emergency.
ECG disposable electrodes, preparing adult ECG electrodes, stress ECG electrodes.Iron, copper, scraps sellers
Disposable ECG electrodes, esu pads, esu pencils .Manufacture
ECG/TMT/CTG papers, medical gels, ultrasound paper, ECG electrodes, plain thermal paper rolls, PFT/spirometry mouthpieces & circular charts .Manufacturer
Disposable ECG electrodes.
Ecg cable, eeg cable, nibp cuff, patient monitor, ecg electrodes, medical connectors, spo2 sensor, temperature probe, ekg cable, spo2 extension cable, ecg trunk cable.
ECG gel, also known as electrocardiogram gel or EKG gel, is a conductive medium used in electrocardiography (ECG) procedures to improve the quality of electrical signal transmission between the skin and the electrodes of the ECG machine. Here's more information about ECG gel: Purpose: The primary purpose of ECG gel is to enhance the conductivity and reduce impedance between the skin and the ECG electrodes. This improves the quality and accuracy of the electrical signals detected by the electrodes, resulting in clearer and more reliable ECG readings. Composition: ECG gel is typically a water-based, conductive gel formulated to be non-greasy, non-staining, and hypoallergenic. It may contain ingredients such as water, glycerin, propylene glycol, carbomer, preservatives, and conductivity-enhancing agents. Conductivity: ECG gel is formulated to have high electrical conductivity, allowing it to effectively transmit electrical signals between the skin and the electrodes. This conductivity helps minimize impedance and artifacts, ensuring accurate ECG readings even in challenging conditions. Viscosity: ECG gel is usually designed to have a suitable viscosity that allows for easy application and smooth spreading on the skin. It should be thick enough to stay in place during the procedure but not so thick that it hinders electrode placement or skin contact. Compatibility: ECG gel is compatible with various types of ECG electrodes, including disposable electrodes, reusable electrodes, and adhesive electrodes. It can be used with both standard ECG procedures and specialized cardiac tests such as stress tests, Holter monitoring, and echocardiography. Application: ECG gel is applied directly to the skin at the electrode sites before attaching the electrodes. A sufficient amount of gel should be applied to ensure good contact between the electrodes and the skin surface. Excess gel can be wiped away after electrode placement. Hygiene: ECG gel should be stored in a clean and dry environment to prevent contamination. Disposable single-use packets or bottles with dispensing caps are commonly used to maintain hygiene and prevent cross-contamination between patients. Removal: After the ECG procedure, any remaining gel should be wiped off the skin using a clean, dry cloth or disposable wipe. Residual gel left on the skin can cause discomfort or irritation if not properly removed.
An ECG bulb, made of silicone, is a component used in certain types of electrocardiogram (ECG) machines. Here's more information about ECG bulbs made of silicone: Material: ECG bulbs made of silicone are designed to be flexible, durable, and resistant to wear and tear. Silicone is chosen for its properties, including flexibility, biocompatibility, and resistance to temperature extremes and chemical exposure. Purpose: The ECG bulb, also known as an ECG electrode or sensor, is a crucial component of the ECG machine. It serves as the interface between the patient's skin and the machine's electrical circuitry, allowing the machine to detect and record the electrical signals produced by the heart. Design: ECG bulbs made of silicone typically have a bulbous or rounded shape with a flat surface that comes into contact with the patient's skin. The silicone material provides a comfortable and secure fit while ensuring good electrical conductivity for accurate signal transmission. Compatibility: Silicone ECG bulbs are designed to be compatible with specific models of ECG machines. They may come in different sizes and shapes to accommodate different electrode configurations and patient needs. Hygiene: Silicone ECG bulbs are often designed for single-use or disposable use to maintain hygiene and prevent cross-contamination between patients. Disposable ECG bulbs help reduce the risk of infection transmission in clinical settings.
High-conductivity gel for electrocardiography (ECG) is a specialized conductive gel used to improve electrical conductivity between the skin and ECG electrodes during cardiac monitoring procedures. Here's more information about high-conductivity gel for ECG: Purpose: The primary purpose of high-conductivity gel is to reduce impedance and improve the transmission of electrical signals between the skin and the ECG electrodes. This ensures accurate and reliable recording of the heart's electrical activity during ECG testing. Composition: High-conductivity gel is typically water-based and contains conductive agents that enhance its electrical conductivity properties. Common ingredients may include water, glycerin, propylene glycol, carbomer, electrolytes (e.g., sodium chloride), and preservatives. Conductivity: High-conductivity gel is formulated to have superior electrical conductivity compared to standard ECG gels or other electrode contact solutions. This allows for better signal quality and minimizes the risk of artifacts or interference during ECG recordings. Viscosity: The gel's viscosity is designed to be suitable for easy application and spreadability on the skin. It should be thick enough to adhere to the skin and maintain contact with the electrodes but not too thick that it hinders electrode placement or skin contact. Non-Staining: High-conductivity gel is typically formulated to be non-greasy and non-staining, ensuring minimal residue on the skin after use. This helps maintain patient comfort and prevents staining of clothing or bedding. Compatibility: High-conductivity gel is compatible with various types of ECG electrodes, including disposable electrodes, reusable electrodes, and adhesive electrodes. It can be used with standard ECG machines and Holter monitors. Application: Before applying the gel, the skin should be cleaned to remove any oils, lotions, or dirt that may interfere with electrode contact. A thin layer of high-conductivity gel is then applied to the skin at the electrode sites before attaching the electrodes. Hygiene: High-conductivity gel should be stored in a clean and dry environment to prevent contamination. Disposable single-use packets or bottles with dispensing caps are commonly used to maintain hygiene and prevent cross-contamination between patients. Overall, high-conductivity gel plays a crucial role in ensuring optimal electrode-skin contact and signal quality during ECG testing. Its superior conductivity properties make it an essential accessory in cardiac diagnostic procedures, allowing for accurate interpretation of the heart's electrical activity.
ECG cable, EKG cable, spo2 sensor, Nibp cuff, temperature probe, ESU pencil, ecg electrode, IBP cable.
ECG: 12-lead resting PC-ECG with auto interpretation VCG: Vector-cardiograph with auto interpretation Hardware Features: High sampling rate of 1000Hz Digital filter system Applying anti-baseline-drift technology ensuring the stability of ECG baseline Wilson and Frank hookup system Meet the international standard of IEC60601-1 Easy operation and perfect printout Diagnosis of coronary heart disease Perfect time domain, frequency domain and non-linear HRV analysis Perfect ECG database management system Specification for PC-ECG: Sample rate: 1000Hz, simultaneous 12 leads recording Resolution:12bit Power: 5.0V (DC) Patient Insulation: 4000V AC Defibrillation Protection: Built-in box Digital resolution: 2V Frequency response: 0.05-250 Hz Common mode rejection: >90dB Input impedance: >10MΩ Time constant: 3.2 s Max electrode potential: ±300mV DC Dynamic range: ±10mV Isolate voltage: 4000V Current leak:
1.Product Description ECG (electrocardiography) is a method of collecting electrical signals generated by the heart. This allows us to understand the level of physiological arousal that someone is experiencing, but it can also be used to better understand someones psychological state. 2.Product Details Properties: Medical Materials & Accessories Brand Name:GE Cable material: TPU cable Cable Leadwires: 3 leads/5 leads Standard: AHA/IEC Certificate: CE, ISO Other Service: OEM&ODM Sample: Available MOQ: 1pc Warranty:6 months Supply Ability: 1000 Piece/Pieces per Week 3.Shipping and Packing Port:Shenzhen port, or as you need Shipping: DHL/FedEx/EMS/UPS/TNT Packaging Details: Wrap with transparent PU plastic bag, each bag with 1 piece. 4.Payment Terms Payment Terms:L/C,D/A,D/P,T/T,Western Union,Money Gram 5.Main Products We Supply Reusable/ Disposable Spo2 Sensor Spo2 Extension Cable ECG/ EKG Cable with leadwires ECG /EKG Trunk Cable Temperature Probe Fetal & TOCO Transducer IBP Cable and Transducer NIBP Cuff and hose 6.Our Services: More competitive factory price. Fast delivery (1-5 days, we are a manufacturer, have enough products in stock.) Quality 100% assured (All products are made of medical TPU material) Samples available (accept trail order) One piece MOQ is acceptable. OEM & ODM service