1.Introduction JCZ5 7.2 kv vacuum contactor HVJ6-7.2 series indoor high-voltage AC vacuum contactor has two types: One is Mechanical holding type, the other is Electromagnetic holding type. It is applicable for three-phase AC 50HZ power system of rated voltage 7.2KV and below and rated current up to 630 A to open and close circuit remotely and control electrical equipment like high-voltage motor, transformer and capacitive load. It is especially suitable for fields operated frequently. The contactor uses the international fashionable up and down structure arrangement and has the advantages of small, light, easy to maintain and form a complete set of F-C circuit equipment. 2. Service condition a) Ambient air temperature: -25- +40. b) Altitude not exceed 2000m c)Humidity: -Relative humidity: daily mean not higher than 95,monthly mean not higher than 90; -Aqueous vapor pressure: daily mean not exceed 2.2 KP, monthly mean not exceed 1.8 KP Ambient air should not be obviously polluted by corrosive or flammable gas or vapor; C)Free of frequent severe vibration; When running, angle of inclination between installation surface and horizontal plane should not exceed 5. Main technical parameters Rated voltage: 7.2 kv Control voltage: 110V, 220V Rated current: 200A, 400A, 630A Contacts separation: 4.5+1-0.5mm Over travel: 1.5±0.5 mm Main circuit power frequency voltage withstand: 32000 V Auxiliary circuit power frequency withstand voltage: 2500 V Control circuit power frequency withstand voltage: 2000 V Making capacity: 10le,100 times Breaking capacity: 8le, 25 times Limit breaking current(A): 10le Mechanical life times: 30104 Weight: 28KG
1.Introduction JCZ5 12kv vacuum contactor HVJ6-12 series indoor high-voltage AC vacuum contactor has two types: One is Mechanical holding type, the other is Electromagnetic holding type. It is applicable for three-phase AC 50HZ power system of rated voltage 12KV and below and rated current up to 630 A to open and close circuit remotely and control electrical equipment like high-voltage motor, transformer and capacitive load. It is especially suitable for fields operated frequently. The contactor uses the international fashionable up and down structure arrangement and has the advantages of small, light, easy to maintain and form a complete set of circuit equipment. 2. Service condition a) Ambient air temperature: -25- +40. b) Altitude not exceed 2000m c)Humidity: -Relative humidity: daily mean not higher than 95,monthly mean not higher than 90; -Aqueous vapor pressure: daily mean not exceed 2.2 KP, monthly mean not exceed 1.8 KP Ambient air should not be obviously polluted by corrosive or flammable gas or vapor; C)Free of frequent severe vibration; When running, angle of inclination between installation surface and horizontal plane should not exceed 5. Main technical parameters Rated voltage: 12000 v Control circuit: 110V 220V Rated current: 200A 400A 630A Contacts separation: 5+1-0.5 mm Over travel: 1.5±0.5 mm Main circuit power frequency withstand voltage: 42000 v Auxiliary circuit power frequency voltage withstand: 2500 v Control circuit power frequency voltage withstand: 2000 V Making capacity: 10le,100 times Breaking capacity: 8le, 25 times Limit breaking current(A): 10le Mechanical life times: 30104 Weight: 32KG
Electronic instruments.
Electronic equipment.
Food products, fruit and recreational plants, palm trees, generators, transformers, household electronics, ev charging stations, accumulators and battery systems, cooling appliances and frigotic systems for vehicles, furnitures (office and household types), copper tubes, powder metals for 3d printers, electrical equipment, defense products most notably drones (strategic /tactical), carrying boxes..Trade, sourcing and investment intelligence, supply chain development services, trade facilitation, inspection, operations support, full fledged trade/supply chain agency services
Pa6 wheel , ms sheets, transformer coil, carbon steel nails for concentrate, hexagonal wire mesh, tiles, led screen, metric bolt, serum tube, drop in anchor, threaded road connectors, pipe clamp, heat exchanger u pipe, flat strips, anchor bolt hollow wall, sugar, cashew, lakadong turmeric, banana powder, raisins..Sourcing
Part NO Coil Voltage 50/60HzNumber of PolesFull Load (A)Maximum Voltage 25 FLA -2 Pole QCA-25224225120 QCB-252120240 QCC-252208/240 30 FLA-2 Pole QCA-30224230120 QCB-302120240 QCC-302208/240 40 FLA-2 Pole QCA-40224240120 QCB-402120240 QCC-402208/240
Series ac contactor is suitable for using in the circuits up to the rated voltage 660v ac 50hz, rated current up to 95a, for making, breaking, frequently starting & controlling the ac motor. Combined with the auxiliary contact block, timer delay & machine-interlocking device etc, it becomes the delay conactor, mechanical interlocking contactor, star-delta starter. With the thermal relay, it is combined into the electromagnetic starter. The contactor is produced according to iec947-2, vde0660 & bd5452.
The contactor is suitable for using in the circuits up to the rated voltage 660v ac 50hz or 60hz, current 300a, for convertible controlling the motor. It's mechanical interlocking device ensures contact changeover of the two convertible contactor.
Power semiconductors, like diodes, thyristors, modules, bridge rectifiers, rotating assemblies, surge suppressors for inverters, ups, battery chargers, furnaces, dc drives, apfc panel, eot cranes, welding machines, etc.
Electronics, mobile phones.
White Cement, White Clinkers, Petroleum Products, Urea, Electronics, Camera And Printers, Organic Waste Treatment Products ( Antizyme Eco Enzyme Bacteria, To Avoid The Blockage And Avoid The Bad Smell From The Wastage Area ).
* 200 Amps Normally Open 24VDC with auxiliary switch * Double coils * Customized available
Fuses, switch, electric meter, electrical contactor, circuit breakers, current transformer, blower fan, cooling fan, water treatment equipment.
HVJ3 12KV VACUUM CONTACTOR Detailed product description: The vacuum contactor is mainly used in the power system with AC 50Hz and rated voltage 12kV, for making or breaking circuit and to make electromagnetic starter with suitable protective device and F-C switchgear. Working condition: 1) Altitude should not be over 1,000m; 2) Ambient temperature: -5~40°C; 3) Average temperature in 24 hour not exceed 35°C; 4) When the highest temperature is 40°C, the relative humidity should not be higher than 50%; 5) Pollution degree: class 3 .Main models and technical parameters Rated voltage: 12 KV Control voltage: 220/110/380 Rated current: 160A, 250A, 400A, 630A Clearance: 5±0.5 mm Over travel: 2±0.2 mm Pressure: >85N Main circuit power frequency withstand voltage: 42000 v Auxiliary circuit power frequency withstand voltage: 2500 v Control circuit power frequency withstand voltage: 2000 v Making capacity: 10Ie,100 times Breaking capacity: 8Ie,25 times Limit opening current(A): 10Ie Overload: 8Ie,10 s Mechanism life: 1 million times Weight: 30KG Note: â??Ieâ?? represents the rated current of main circuit Model Rated voltage(v) Rated current ï¼?Main circuitï¼?(A) Parameter of main contacts Power frequency Withstand voltage V(effective value) Main circuit Control circuit Clearance (mm) Over travel (mm) pressure (N) Main circuit Auxiliary circuit Control circuit HVJ3-12/160 12000 220/110/380 160 5±0.5 2±0.2 >85N 42000 2500 2000 HVJ3-12/250 12000 220/110/380 250 5±0.5 2±0.2 >85N 42000 2500 2000 HVJ3-12/400 12000 220/110/380 400 5±0.5 2±0.2 >85N 42000 2500 2000 HVJ3-12/630 12000 220/110/380 630 5±0.5 2±0.2 >85N 42000 2500 2000  Model Making capacity Breaking capacity Limit opening current(A) Overload Mechanism life Weight(kg) HVJ3-12/160 10Ie,100times 8Ie,25times 10Ie 8Ie,10s 1million times 30 HVJ3-12/250 10Ie,100times 8Ie,25times 10Ie 8Ie,10s 1million times 30 HVJ3-12/400 10Ie,100times 8Ie,25times 10Ie 8Ie,10s 1million times 30 HVJ3-12/630 10Ie,100times 8Ie,25times 10Ie 8Ie,10s 1million times 30 Note: â??Ieâ?? represents the rated current of main circuit
CJ20 220v ac types of contactor is suitable for frequency 50Hz, rated voltage up to 660V, rated current up to 630A. It is mainly used foe making or breaking electric circuits at a long distance,and starting, stopping,controlling the AC motor frequently . It is used in combination with thermal relay to compose magnetic motor starter. The product conforms to IEC60947-4-1 and GB14048.4
Main Range : TeSys Product name : TeSys D Product or component type : Contactor Device short name : LC1D Contactor application : Motor control Resistive load Utilisation category : AC-3 AC-1 AC-4 Poles description : 3P Pole contact composition : 3 NO [Ue] rated operational voltage :
Main Range : TeSys Product name : TeSys D Product or component type : Contactor Device short name : LC1D Contactor application : Motor control Resistive load Utilisation category : AC-3 AC-4 AC-1 Poles description : 3P Pole contact composition : 3 NO [Ue] rated operational voltage :
Circuit breaker, contactor, meter, fuse breaker, timer, arrester.
Mould case circuit breaker, mini circuit breaker, isolating switch, thermal relay, time relay, general relay, timer, contactor, starter, frequency transformer, soft starter, current transformer, kwh meter, panel meter, multimeter, thermocouple and thermal resistance, indicator lamp, pushbutton, warning light, dual power transfer, limited switch, micro switch, toggle switch, changeover switch, foot switch, fuse, high-voltage fuse, light arrester, surge protective device, distribution box, industrial plug and socket, copper connection, cable fitting, terminal block, plastic accessories, connector, welding machine, compass, rectifier, food waste disposer, bell, axial fan.