Toyota rav4 head lamp 64*52.5*50CM/4PCS
This is forThis is for Man F2000 taillight, we do for aftermarket. We could provide you sample for free to check our product. If you are interested in our products and our company, please kindly let us know your need, we will try our best to coordinate with you. At same time we are confident that our best quality, competitive price, shortest delivery time, good service can deeply move you!, we do for aftermarket. We could provide you sample for free to check our product. If you are interested in our products and our company, please kindly let us know your need, we will try our best to coordinate with you. At same time we are confident that our best quality, competitive price, shortest delivery time, good service can deeply move you! 64*52.5*50CM/4PCS
Test-630 is a six phase current output and six phase voltage output protection relay tester with 5.Eight pairs of binary input and four pairs of binary output FEATURES Integration in the host crystal 8.4 inches true color, light weight and easy to carry. Built-in high-speed and high-performance industrial computer embedded operating system, running stable and reliable, also can test by connecting PC. Panel embedded user-friendly buttons, and the panel can also be an external keyboard and mouse. High-precision DAC to 12 Road, simultaneously output to ensure the high precision and good linearity of the waveform. 5Matching electromagnetic compatibility components, can improve on-site anti-electromagnetic interference, protection devices can connect the electromagnetic compatibility to test. Analog output of the front panel, switch the amount of terminal design in the upper cover, all the wiring does not affect the operation of the panels and the test parameters of the surveillance. The latest thermal structure design to ensure the best ventilation. Automatically determine over current, over voltage, overload and short circuit, if the temperature is too high, the anomalies and misuse warning of the data will show up promptly. Using voltage, current amplifier AC / DC sharing, output stage uses a unique ultra-linear amplifier technology, high precision and reliability. six-phase AC output voltage and six-phase AC current. 12 analog ports and other optional auxiliary DC source output (220V/110V). Interface: RJ45 (Ethernet interface), USB interface (software upgrades, reporting transmission), industrial serial interface (GPS or other serial device use). TEST ITEM U/I Test DC Test Impedance Characteristics Power Direction Test I-T Test Differential Relay Harmonic Test Differential Protection Distance Protection Zero Sequence Protection Setting Group Test State Sequence Synchronization Test Special Test Oscillation Test Metering Instrument Hardware Checkout Low Voltage Protection Fault Recurrence
ALSTOM GBCDG61EG040SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Relay Technical specification Relay model no CDG61EG040SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Aux.Contacts With Flag 3M S/R Output contacts 2M S/R C.T.Secondary 5 amps Frequency 50 Hz Burden 3 VA Operating time 1.3 secs Current setting - E/F 0.5 to 2 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 5 to 20 amps High set conts.With flag CAG 13 / 2M S/R Name plate RFG9125 903 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
Led moving head lamp Skillspecifications: Power:220v-190v /50hz(the other power can order) Lamp:led 1w redx12+1w greenx12+1w bluex12 Power consumption : 80w Control signal: dmx 512 Control channels:12(16bit) 8ch(8bit) Four lights' carton size: L1490*w1405*h1600(mm) N.W:6.75kg(single) Motors:2 Carton or flycase
GBCDG61EG046SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no - CDG61EG046SGCH Relay type - CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting O/C- 2.5 to 10 amps Contacts / Output contacts 3M S/R / 2M S/R C.T.Secondary - 5 amps Frequency - 50 Hz Burden - 3 VA Operating time - 3 secs Current setting - E/F - 1 to 4 amps High set - O/C Setting- 25 to 100 amps High set - E/F Setting- 10 to 40 amps High set - CAG 13 Name plate - RFG9126 904 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.27-1
GBCDG61EG042SHCH IDMT 2 O/C & 1 E/F RELAY WITH HIGH SET Technical specification Relay model no- CDG61EG042SHCH Relay type - CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting - O/C - 0.5 to 2 amps Contacts - 2M2B H/R 2M S/R Output contacts - 2M2B H/R 2M S/R C.T.Secondary - 1 amps Frequency - 50 Hz Burden - 3 VA Operating time - 3 secs Current setting - E/F - 0.2 to 0.8 amps High set - O/C Setting- 4 to 16 amps High set - E/F Setting - 1 to 4 amps High set - CAG 13 Name plate - RFG9126 902 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.29-1
GBCDG61EG044SHCH IDMT 3 O/C RELAY WITH HIGH SET CAG 13 Technical specification Relay model no - CDG61EG044SHCH Relay type - CDG 61 Case size - 3D H 30T Application - 3 O/C Current setting - 0.5 to 2 amps Contacts / Output contacts - 2 N/O 2 N/C H/R C.T.Secondary - 1 amps Frequency - 50 Hz Burden - 3 VA Operating time - 3 secs High set - O/C Setting - 4 to 16 amps High set - CAG 13 High set contacts - 2 N/O S/R Name plate - RFG9126 771 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.29-1
GBCDG61EG054SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no - CDG61EG054SGCH Relay type - CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting - O/C - 0.5 to 2 amps Contacts - 3 N/O S/R Output contacts - 2 N/O S/R C.T.Secondary - 1 amps Frequency - 50 Hz Burden / Operating time - 3 VA / 1.3 secs Current setting - E/F 0.2 to 0.8 amps High set - O/C setting 4 to 16 amps High set - E/F setting 2 to 8 amps High set CAG 13 Name plate RFG9125 902 Outline drawing MFJ 014 Wiring diagram - MADZ 821.27-1
GBCDG61EG057SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no - CDG61EG057SGCH Relay type - CDG 61 Case size - 3D HOR. Application - 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R C.T.Secondary 1 amps Frequency 50 Hz Burden / Operating time 3 VA / 3 secs Current setting - E/F 0.2 to 0.8 amps High set - O/C setting 4 to 16 amps High set - E/F setting 1 to 4 amps High set CAG 13 Name plate RFG9126 902 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
ALSTOM GBCDG61EG041SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG041SGCH Relay type CDG 61 Case size 3D H 30T Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Contacts / Output contacts 3M S/R / 2M S/R C.T.Secondary 5 amps Frequency 50 Hz Burden 3 VA Operating time 3 secs Current setting - E/F 0.5 to 2 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 5 to 20 amps High set CAG 13 Name plate RFG9126 903 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
Specialty Hotmelt Adhesives We also offer Turbomelt range of Hotmelt Adhesives for - Hygiene (Sanitary Pads, Diapers and Panty Liners) - Pet Bottle Labelling (Mineral Water & Carbonated Drinks) - Freezing Cartons (Ice cream, Frozen Food & Medicine) - Air & Automotives (Air Filter Assembly, Head / Tail Lamp Assembly) - Mattresses (Spring Pocket Bonding and Foam Assembly) - Bag Sealing (WPP Bags & Courier Bags for E-Commerce) - Shoe Industry (Fabric Lamination) - Anti Skid Adhesives (Carpet Back Coating & Anti Skid Palletization) - Soap Wrapper - Straw Fixing and Wad Fixing, - Edge banding
GBCDG61EG101ZRCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical Specification Model No - CDG61EG101ZRCH Relay Type - CDG61/CAG17(MRK-III) Application - 2 O/C + 1 E/F Case Size - 3D Horz C.T. Secondary - 5 Amp C.T. O/C Setting - 2.5 - 10 Amps. E/F Setting - 0.5 - 2 Amps Contacts - 2 N/O S/R Flag - Yes Frequency - 50 Hz Burden / D.M.T - 3 Va / 3 Sec High Set Type / Conts. - CAG17 / 2 N/O S/R Highset O/C Setting - 12.5 - 100 Amps. HighSet E/F Setting - 5 - 40 Amps Mounting - Flush Name Plate - RFG9126 903 Outline Diagram - MFJ 014 Wiring Diagram - MADZ821.31
GBCDG61EG058SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no - CDG61EG058SGCH Relay type CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting - O/C - 2.5 to 10 amps Contacts - 3 N/O S/R Output contacts - 2 N/O S/R C.T.Secondary - 5 amps Frequency - 50 Hz Burden / Taps - 3 VA / Std Operating time - 1.3 Secs Current setting - E/F - 0.5 to 2 amps High set - O/C Setting - 25 to 100 amps High set - E/F Setting - 10 to 40 amps High set / High set cont. - CAG 13 / 2 N/O S/R Name plate - RFG9125 903 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.27-1
Gbcdg61eg101zmch Idmt 3 O/c or 2o/c& 1 E/f Relay With Hi Model No : Cdg61eg101zm(M) Cdg61/cag17(Mrk-iii) Application - 3 O/c Burden / D.m.t - 3 Va / 3 Sec. C.t. Secondary - 5 Amp C.t. Case Size - 3d Horz. Contacts (S/r or H/r) - 2 N/o S/r Flag - Yes Frequency - 50 Hz High Set Type - Cag17 Highset Contacts - 2m S/r Highset O/c Setting - 12.5 - 100 Amps. Mounting - Flush O/c Setting - 2.5 - 10 Amps. Name Plate - Rfg9126 774 Outline Diagram - Mfj 014 Wiring Diagram - Madz821.31
Gbcdg61eg101znch Idmt 3 O/c or 2o/c& 1 E/f Relay With Hi Model No : Cdg61eg101zn(M) Cdg61/cag17(Mrk-iii) Application - 3 O/c Burden / D.m.t - 3 Va / 3 Sec. C.t. Secondary - 5 Amp C.t. Case Size - 3d Horz. Contacts (S/r or H/r) - 2 N/o 2 N/c H/r Flag - Yes Frequency - 50 Hz High Set Type - Cag17 Highset Contacts - 2m S/r Highset O/c Setting - 12.5 - 100 Amps. Mounting - Flush O/c or O/v Setting - 2.5 - 10 Amps. Name Plate Rfg9126 774 Outline Diagram Mfj 014 Wiring Diagram Madz821.32
GBCDG61EG101ZSCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI TECHNICAL SPECIFICATION Model No - CDG61EG101ZSCH CDG61/CAG17(MRK-III) Application - 2 O/C + 1 E/F Case Size - 3D Horz C.T. Secondary - 5 Amps O/C Setting - 2.5 - 10 Amps. Frequency / Tap - 50 HZ / Std Burden / D.M.T - 3 Va / 3 Sec Contacts - 2 N/O 2 N/C H/R E/F Setting - 0.5 - 2 Amps. Flag - Yes High Set Type / Contacts - CAG17 / 2 N/O S/R HighSet E/F Setting - 5 - 40 Amps HighSet O/C Setting - 12.5 - 100 Amps. Mounting - Flush Name Plate - RFG9126 903 Outline Diagram - MFJ 014 Wiring Diagram - MADZ821.32
GBCDG61EG102ZMCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Model No : CDG61EG102ZMCH CDG61/CAG17(MRK-III) APPLICATION - 3 O/C BURDEN - 3 VA C.T. SECONDARY - 1 AMP CT. CASE SIZE - 3D HORZ. CONTACTS (S/R OR H/R) - 2 N/O S/R D.M.T - 3 SEC. FLAG - YES FREQUENCY - 50 HZ HIGH SET TYPE - CAG17 HIGHSET CONTACTS - 2M S/R HIGHSET O/C SETTING - 2.5 - 20 Amps. MOUNTING - FLUSH O/C SETTING - 0.5 - 2 Amps. Name Plate RFG9126 771 Outline drawing MFJ 014 Wiring Diagram MADZ821.31
Model s40a (3*40a, 3*150v) has large lcd display and panel control facilities. No external pc is required. It can easily test many types of relays, including distance relay, df/dt relay. The rotating mouse and quick touch buttons make the operation very easy. 3*40a, 3*150v Additional 200ma ac current source Aux dc (24v, 110v, 220v) 4 binary inputs, 1 binary output Locally with color lcd (universal relay tester, relay test equipment, 3 phase relay test set, secondary injection test system)