Used for the fractures of the clavicle shaft. Plate Features: Anatomically pre-shaped, twisted design. Due to Lateral superior placement, there is less need to detach muscles than with anterior placement. Undercuts reduce impairment of blood supply. Also used in osteoporotic bone and in multi fragment fractures. Tapered plate tip facilitates percutaneous insertion and prevents soft tissue irritation.
Mini Cortex Screws Dia : 1.5mm Total Length : 6mm to 12mm (with 1mm diff.) : 14mm to 20mm (with 2mm diff.) Core Dia : 1.0mm Drill Bit : 1.1mm Tap : 1.5mm
Contents 4.5 mm Cortical Screws 8 Screws each of 14, 16, 18, 20, 22, 24, 26 & 28mm 64 nos. 16 Screws 30mm 16 nos 12 Screws each of 32, 34, 36, 38, 40 & 44mm 72 nos 6 Screws each of 42, 46, 48, 52 & 56mm 30 nos 5 Screws 60mm 5 nos 4 Screws each of 64 & 68mm 8 nos.
Contents ST500.01 : Guide Pin With Thread : 6 nos. ST500.02 : D.H.S. Angled Guide 1350 : 1 no. ST500.03 : Wrench for D.H.S. Screws : 1 no ST500.04 : D.H.S. Triple Reamer : 1 no ST500.05 : Impactor : 1 no ST500.06 : Tap for D.H.S. Screws : 1 no ST500.07 : Coupling Screws for Plate insertion : 1 no ST500.08 : Coupling Screw for screw Removal : 1 no
Mini Fragment Set Contents Instrument for 2.7 mm Screws ST003.01 Drill Bit 2mm 2 nos. ST203.03 Tap 2.7mm 2 nos. ST303.00 Tap Handle 1 no ST503.02 Drill Sleeve : 2mm 1 nos ST603.02 Tap Sleeve : 2.7mm 1 no ST113.01 Mini Neutral & Load Drill Guide 1 no ST403.02 Screw Driver with Sleeve 1 no ST013.01 Mini Depth Gauge 1 no ST013.04 Self Retaining Retractor 1 no
ST810.00 Large Fragment Set Contents ST992.05 : Drill Bits - 3.2mm : 2 nos. ST992.09 : Drill Bits - 4.5mm : 2 nos. ST903.03 : Counter Sink : 1 no ST203.07 : Bone Tap : 4.5mm : 2 nos ST103.09 : Bone Tap : 6.5mm : 1 no ST503.03 : Drill Sleeve 3.2mm / Tap Sleeve 4.5mm : 1 no ST403.04 : Large Hexagonal screw Driver : 1 no ST013.03 : Large Depth Gauge : 1 no ST113.03 : Neutral & load Drill Guide : 1 no ST303.00 : Tap Handle : 1 no
These plates deal with fractures and malunions of the clavicle shaft Plate Features: Anatomically pre-shaped, twisted design. Due to Lateral superior placement, there is lesser need to detach muscles than with anterior placement. Undercuts reduce impairment of blood supply. Tapered plate tip facilitates percutaneous insertion and prevents soft tissue irritation.
Contents Instruments ST992.04 Drill Bit (S.S.) : 2.5mm 2 nos. ST003.02 Drill Bit (S.S. Quick Coupling End) : 2.5mm 1 nos. ST992.07 Drill Bit (S.S.) 3.5mm 1 no ST903.02 Counter Sink 1 nos ST203.04 Cortical Tap : 3.5mm 2 no ST203.05 Cancellous Tap : 3.5mm 2 no ST203.06 Cancellous Tap : 4mm 1 no
Contents ST853.08 : Wire Holding Forceps : 2 nos. ST853.09 : Wire Bending Forceps : 1 nos. ST853.07 : Wire Cutter Cum Plier 6 : 1 nos. ST853.05 : Wire Passer : small : 1 nos. Wire Passer : medium : 1 nos. Wire Passer : large : 1 nos. ST853.06 : Wire Tightner : 1 nos. ST853.01 : Bone Awl : 3 nos. ST853.04 : T. Handle : 1 nos.
Contents ST510.01 : Half Rings : 100mm : 6 nos. ST510.02 : Half Rings : 120mm : 8 nos. ST510.03-04 : Half Rings : 140 & 160mm (8 each) : 16 nos. ST510.05 : Half Rings : 180mm : 4 nos. ST510.06 K : Wire Clamps : 20 nos. ST510.07 : Ring Connecting Bolts : 10 nos. ST510.08 : Threaded Rods : 100, 150mm (8 each) : 16 nos.
Indications: The 3.5 mm LCP Extra-articular Distal Humerus Plates are indicated for fractures of the distal humerus. Plate features Left and right plates are anatomically contoured to match the posterolateral distal humerus. Two most distal holes are angled toward the capitulum and trochlea. Plate head tapered to minimize soft tissue irritation. A limited-contact plate design reduces plate-to-bone contact and helps to preserve the periosteal blood supply. Anatomic reduction: Fracture reduction and fixation to restore anatomical relationships. Stable fixation: Fracture fixation providing absolute or relative stability, as required by the patient, the injury, and the personality of the fracture. Early, active mobilization: Early and safe mobilization and rehabilitation of the injured part and the patient as a whole. Preservation of blood supply: Preservation of the blood supply to soft tissues and bone by gentle reduction techniques and careful handling.
The multidirectional and angular stable fixation system (TriLock technology) for the distal radius consists of implant plates, implant screws and the corresponding instruments. Plate thickness 1.3 mm, 1.6 mm, 2.0 mm and 2.2 mm HexaDrive in all screws, cortical and TriLock Consistent screw diameter: 1 twist drill, 1 screwdriver, locking or non-locking
Lag screws compress the fracture fragments together. There are two screw types by which to achieve this. In the Proximal Tibia most often cancellous bone screws are used due to the absence of real cortical bone.
No dig ground anchor / screw pole anchor The No-Dig Ground Anchor offes a faster, cleaner, and easier way to install your mail post. It's an ideal way to avoid digging a hole and mixing concrete, it truly is a time saver Accommodates a standard 4x4 wood post (not included) Includes 5x lag bolts and a 20" length of rebar to twist the screw into the ground. In carton then on pallet or only with wood box pallet.
Wire
Nails
Hip Prosthesis
D.H.S Plate
Product name: Chipboard Screw/chipboard screws with saw/spax screw/sawed chipboard screw Material: Carbon steel, stainless steel, brass. Head type: flat/countersunk, pan, Double Flat, wafer head, CSK with 4(6) ribs Finish: zinc plated, Black Oxide, Nickel, Rupert, Dacromet, and so on Drive Type: Phillips, Pozi, square, Torx Standard: DIN7505 Packing: bulk, plain box, color box, polybag, PP box + wood Pallet
Glass seed beads, size:6/0, 8/0, 10/0, 11/0, 12/0, 15/0, Glass tube, size :2", 3"n, Pvc sequins:5mm, 6mm, 8mm , 10mm.