X-ray generator 1. Hf converter, dc high voltage generator 2. Output: 3.5kw at100kv++ 3. Stationary anode, dual focal spot, large 1.5mm; small 0.6mm 4. Max. Heat capacity: 700kj++910khu++x-ray tube anode heat capacity: 57kj:++76khu++ 5. Voltage range: 40f+110kv 6. Current range: normal fluoroscopy: 0.2--4ma pulse fluoroscopy: 0.2--4ma Hdf fluoroscopy: 0.4--8ma radiography: 30--68ma 1--160mas , 23 steps rf+10 seriers 7. Iris++auto trace the ii field change 8. Semi-transmit shutter
DESCRIPTIOn: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT: 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY : Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND counter Balance Mobile
DESCRIPTION: Titanx RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Floor to Ceiling Column Stand
DESCRIPTION: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Counter Balance Mobile
DESCRIPTION- TITANX 100 RADIOGRAPHY RATING- 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT 8KW RECTIFICATION- Full Wave Rectified TIMER- 0.06 to 5 sec DIGITAL DISPLAY- Digital Display of mAs, kV & mA X-RAY TUBE- XD-3/Imported POWER SUPPLY- 230 Voltage AC, 15 Amps LINE REGULATION- 10% 0.6max PROTECTION- Electronic overload Protection TUBE STAND- Spring Balance
X ray machines, Mammography machines, digital Xray, OPG machines, C Arm, dental Xray, Portable X ray.Manufacturing and export
1) 220V power supply voltage of plus or minus 10% of Pathology 2) Rated 60W. Technical specifications Mainframe exterior size 280 * 200 * 80MM Ball-2009140 * Spiral (excluding Canada longituba) Weight 2.2kg mainframe Ball pounds Temperature 5-40 degrees Relative Humidity
The portable series gas insulation x-ray flaw detector can be widely used in shipbuilding, Chemistry, aviation, boiler, pressure container, national defense industry for ndt flaw detection. It absorbs different lever of x-ray based on the different thickness of materials. From the x-ray Perspective negative, we can see the faults of materials, parts as well as interior of weld joint. According to the fault shape, degree and position, we can confirm the quality of materials and Products. The portable x-ray flaw detectors are divided into two series: directional radiation flaw Detection and round radiation flaw detection. Round radiation is efficiently used in circle weld Joint, matched with the ribbon shape negative, the labor force can be reduced and the working Efficiency be increased greatly. Portable x-ray unit(xxg-3005) X-ray tube voltage 170-300kv X-ray tube current 5ma Focus spot size; 2.5*2.5mm Max. Penetration- a3 steel 50mm(5min exposal, d>=1.5) Tube voltage stability +-5% Tube current stability +-5% Generator external size 330*330*700mm Generator weight: 40kg Controller size: 390*380*170mm (including handle) Controller weight: 12kg Input power: 220v+-10%;ac 50hz, capability>=3.6kva Operating temperature: -20~+40
1 The device for high frequency DC portable dental X-ray machine,the advantages of small volume,light weight,low-dose X-ray,high efficiency,etc. 2 with high capacity battery,no external power supply is needed,and one charge can meet the requirement of long shooting 3 Provides the convenience for the patient,without leaving dental chair,saves time,improves the efficiency,is the best choice for mobile trearment. 4 Using LCD,large visual area,high resolution 5 Compatible with any brand of sensor 6 Can be handheld shooting and the selection of remote control frame shooting.
Type of Tube Stationary Anod X-ray Tube Focal Spot 1.4mm Rating 50mA at 85 KVP Inbuilt LED Collimator Safety Voltage Over Load Protection Input Power 220V-50/60Hz - AC, Single Phase Timer 0.06 to 8 second (24 steps) Indicates Main ON, Overload and x-ray ON Type Truly Portable Carry away box type Machine
Application:- X-Ray unit is used for radiographic work and useful for Chest, Cervical, Exteremities. Panel control and functional description :- SX-30mA Ray unit provides case of operation with simple feather touch as well manual control the use can adjust the required voltage rating just by selecting V/comp knob that can visible on Voltage display and set up to till overload and for proper setting keep one step behind the overload Voltage at 220 V by using Voltage Compensator.It is also used for Veterinary clinics. REAL PORTABLE X-RAY:- Truly Portable Carry away box type Machine Voltage Over Load Protection LED Collimator Micro Processor primarily based Digital with Accuracy of zero.01 Sec. Exposure Time is Set by soft button . Hand switch for exposure in single touch Weight 18Kg of 30mA and 19.5kg of 50mA TECHINICAL SPECIFICATION :- Type of Tube Stationary Anod X-ray Tube Focal Spot 1.2mm Rating 30mA at 85 KVP Inbuilt LED Collimator Safety Voltage Over Load Protection Input Power 220V-50/60Hz - AC, Single Phase Timer 0.06 to 8 second (24 steps) Indicates Main ON, Overload and x-ray ON
Rocker safety lock design, make your operate much safer High quality x-ray monoblock assures more details, less dose Symmetrical adjustable collimator for accurate positioning and better exposure protection Aviation aluminum connectors, connection reliable, more safety Advanced dislocation braking system, flexible movement, flexible braking Multifunctional cassette storage box design
X ray system digital fluoroscope manufacturer PLD6000 Usages of Digital Medical X-ray Radiography&fluoroscopy Unit PLD6000 This digital x ray machine/x ray machine for sales is available for medical teaching, research, medical units for X-ray spot film gastrointestinal photography, remote compartment, and other traumatic perspective X-ray photography and other routine check.The digital x ray machine/x ray machine for sales can be apply to the esophagus, chest, stomach, abdomen, limbs for fluoroscopy and spot film photography. Features of X ray system for fluoroscope PLD6000 1.base the optimization principle to produce, excellent config of whole system, satisfy clinical personalized requirement. 2.latest technology of high frequency mainframe, digital image collection, obtain the high quality image easily. 3. Medical digital x ray machine has friendly user interface , excellent operation system, which can make the equipment more convenient and easy to operate. 4.multiple safety control, make the image quality and radiation dose to achieve organic balance. 5.strong function of digital image processing, overall compatible with Dicom 3.0 network application . z
1. When adding up voltage, total current is less than 2a and total power is 500w; 2. The current and voltage of x-ray tubes are fixed in three groups, they are: X exposure voltag (kvp) 60 65 70 X-ray current (ma) 0.5 0.85 1.10 3. When adding up voltage, total current is less than 2a and total power is 500w 4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1 5. The three groups of voltage (60kv, 65kv, 70kv) are adjustable. 6. Wireless remote control in any angles within 10 meters part form the control box 7. The parameter of x-ray generator (bulb tube head) the parameter of x-ray tubes A focus index: 0.3*0.3mm2 B. The voltage of the-highest-voltage generator: 90kv C. The highest inverse peak voltage: 90kv D. Filament characteristic: vf=5v+0.5v, f=3a E. Target surface obliquity: 12 F. The cooling manner of bulb tube head: oil immersion The parameter of x-ray generator (bulb tube head): A. Focus-skin distance: 200mm B.The thickness of filter-ray film: more than 1.5mmal C.The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h) D. The manner of limiting beam: using planigraphic device
Detecting such as stone ,sand,teflon,fe,sus ,non-fe,harder material and so on in the food stuff
Specifications: Tube Voltage): 60kV Tube Current: 1mA Exposure Time: 0.02~2S Tube Focus: 0.3*0.3mm Frequency: 30kHz Battery: DC14.8V 6400mA Rated Power: 60VA Charger Input: AC100V-240V±10% Charger Output:DC16.8V Weight:2.2kg Size:138*165*185mm The distance from skin to cone: 130mm
Key Features * Blu-ray Disc Support * UHD Blu-ray Disc Support * BDXL Support * TV Connectivity * M-DISC Support * Silent Play * Win 10 Compatible Tech Specs Max Speed - UHD Blu-ray 6x UHD BD-ROM Read BD 6x BD-R Write 6x BD-R DL Write BDXL 4x BD-R TL Write 4x BD-R QL Write DVD 8x DVD+/-R Write 6x DVD+/-R DL Write 5x DVD-RAM Write CD 24x CD-R write * Host interface - USB 2.0 (3.0 Compatible) * Dimentions (W x H x D) - 144 mm x 14.6 mm x 156 mm * Net Weight - 270 g * MTTF(Mean Time To Failure) - 60,000 POH (Power On Hours)
Key Features * Blu-ray Disc Support * UHD Blu-ray Disc Support * BDXL Support * M-DISC Support * Silent Play * Win 10 Compatible Tech Specs * Max Speed - UHD Blu-ray 8x UHD BD-ROM Read BD 16x BD-R Write 12x BD-R DL Write BDXL 8x BD-R TL Write 6x BD-R QL Write DVD 16x DVD+/-R Write 8x DVD+/-R DL Write 5x DVD-RAM Write CD 24x CD-R Write * Host interface - SATA (Serial ATA) * Dimentions (W x H x D) - 146mm x 41.3mm x 165mm (Without Bezel) * Net Weight - 650g * MTTF(Mean Time To Failure) - 60,000 POH (Power On Hours)
Key Features * Blu-ray Disc Support * BDXL Support * M-DISC Support * Silent Play * Win 10 Compatible Tech Specs * Max Speed UHD Blu-ray 6x UHD BD-ROM Read BD 6x BD-R Write 6x BD-R DL Write BDXL 4x BD-R TL Write 4x BD-R QL Write DVD 8x DVD+/-R Write 6x DVD+/-R DL Write 5x DVD-RAM Write CD 24x CD-R Write * Host interface - SATA (Serial ATA) * Dimentions (W x H x D) - 128mm x 9.5mm x 127mm (Without Bezel) * Net Weight - 129g * MTTF(Mean Time To Failure) - 60,000 POH (Power On Hours)