1. Current overload or line surge shutdown 2. High temperature compressor shutdown. 3. High pressure alarm shutdown. 4. Low pressure alarm shutdown. 5. Low oxygen cocentrator alarm. Oxygen concentrator: 0.5-5L/min Purity: 95%+_3% Working system Continuous Power Supply AC230V.50Hz/AC220V.60HZ AC120V.60Hz Power: 390VA Net Weight: 16kg( Gross weight: 18.5kgs) Warranty: Long-life compressor designed for 1000 hours of maintenance-free use. Size: 33*26*54cm
Oxygen Mask Product Code: MED 105 Specifications: Non- Sterile, individually packed in a polybag Size/Strength: Adult 210 cm (7ft), Child 210 cm (7ft) Description Made from special non-toxic medical grade PVC. Two holes to allow carbon dioxide exhaled by the patient to escape. Nasal clip for secure fixation over the patientâ??s nose. Elastic band for placement around the head. Transparent tubing to connect the mask to the oxygen source.
The popular portable oxygen machine car oxygen concentrator adjustable oxygen-concentrator Intelligent self-checking system with error code showing in LCD Super low noise 24 Hours Continuous Working Long lifespan of Molecular Sieves
GAZTRON engineering private limited is one leading manufacturers and exporters of PSA based medical oxygen gas generation plant & Oxygen Gas Plants, medical oxygen manufacturing plant in India. For More Information Kindly
medical oxygen Oxygen connector 1.5M/1.8M/2M/5METC
Medical grade PIC/S GMP factory
OXYGEN CYLINDERS 150 Bar, Valve: GF-6A, Certificate: ISO9001/ISO13485.
PART # SERVICE PRESSURE WATER CAPACITY DIAMETER LENGTH WEIGHT OXYGEN ã?? psi bar lbs liters in mm in mm lbs kgs cu ft liters M6 2216 153 2.3 1 3.19 81 11.81 300 2.18 0.8 6 170 M7 2015 139 3 1.4 4.37 111 9.45 240 3.53 1.6 7 198 M9 2015 139 3.7 1.68 4.37 111 11.03 280 3.86 1.75 9 255 MD 2015 139 6.2 2.8 4.37 111 16.65 423 5.51 2.5 15 425 Jumbo D 2216 153 8.8 4 5.42 133 17.32 440 8.8 4 22.9 647 M22 2216 153 8.5 3.9 5.24 133 16.93 430 8.6 3.9 22 623 ME 2015 139 10.0 4.55 4.37 111 25.63 651 7.72 3.7 24 680 M33 2216 153 12.8 5.8 6.89 175 15.75 400 14.1 6.4 33 935 M42 2216 153 16.5 7.5 6.89 175 19.29 490 16.75 7.6 42 1189 M60 2216 153 23.2 10.5 7.28 185 23.1 587 22.92 10.4 60 1699 M90 2216 153 34.7 15.7 7.28 185 32.7 831 30.86 14 90 2549
Warranty:- 1 year warranty capacity:- 5LPM
GAZTRON engineering private limited We are manufacturers and exporters, authorized, distributor of Medical Oxygen Generator Plant in India.
Water capacity 46.7 Litre , weight 50 kg , 7 Cubic gas , 5.3 MM
we are provide medical oxygen cylinder 46.7 litres water capacity & gas 7 cubic and also provide 10.2 litres water capacity , gas 1.5 cubic
Power Source AC 220V, 50-60Hz (Optional: AC 110V, 50-60Hz) Heated Plate 150W Thermal Cut Off 95±6oC Display Three digit, 0.56 inch, 7 segment Led Temperature Monitoring 0-75oC Max-temperature of Heated Plate 85oC Heated Wire AC 22V 60W, 50-60Hz Power Rate 220W Alarm Yes Temperature Control Setting Invasive Mode:Chamber outlet: 35.5-37oC, Airway: 35-40oC Non-invasive Mode:Chamber outlet: 31oC, Airway: 28-34oC Range 10-70oC, Accuracy: ±2oC (In 25-45oC temperature range)
Oxygen generator uses molecular sieve pressure swing adsorption principle, takes air as raw material, and absorbs nitrogen and other gas components to improve oxygen concentration to produce oxygen-enriched air. Oxygen concentration ranges from 90% to 96% (VA/), which can provide oxygen for therapy or relieve discomfort caused by hypoxia. When the equipment works, compressed air is injected into a closed adsorption tower filled with molecular sieve, which causes the pressure in the adsorption tower to rise. With the increase of environmental pressure, the molecular sieve absorbs a large amount of nitrogen in the compressed air, while oxygen in the compressed air still exists in the form of gas and is collected through a certain pipeline. This process is often referred to as the "adsorption" process. When the nitrogen adsorbed by the molecular sieve in the container reaches the critical state of adsorption saturation, the adsorption tower is blown to reduce pressure. With the decrease of environmental pressure, the ability of molecular sieve to adsorb nitrogen decreases, and nitrogen is released back to the gas phase from the molecular sieve and discharged as waste gas. This process is often called "desorption". In order to ensure the continuous and stable output of oxygen, the oxygen generator usually adopts two (or more) molecular sieve adsorption towers, which are controlled by rotating separation valves, so that one adsorption tower is in the adsorption process while the other adsorption tower is in the desorption process, and the two work alternately to complete the continuous oxygen production process.
Flow rate: 0.5~5L/min Oxygen concentration: 93%±3% Input power: AC220,50Hz Power consumption: 450VA Noise level: less than 70dB(A) Dimension: 33X34X53(cm) Weight: 16.6KG
Features A Touch operate multi-functional units. 5Liter with 93%±3% oxygen purity output for COPD users Oxygen Purity Display by Numbers ( Accuracy 00.0%) Timer Large 6' LED Light Display all functional data Accumulated total running hours Special features only provided by AngelBiss Technology The world's NO. 1 Oxygen Output Purity Fluctuation rate controlled within 0.1%. Automatic heavy humidity remove molecular sieve Independent Oxygen outlet & nebulizer outlet system Child Lock settings 3 years warranty or 18000hours lifetime Durable use for environment areas at high temperature (45C), high altitude (4500m). Accessories