Origin : Brasil and Colombia. calibers: 0.7 to 10 (5% Tolerance for 06 or 12). distribution: cntr 1x40': 22 pallets (252 boxes) each boxes of 4 kg/pallet. total bx /cntr: 5544 carboardbox. temperature cntr: 7 to 9 for transport and storage . shelf life: 40 days Certification: Global Gap and Grasp. minimum: 4 pallets (air) and sea 1 cntr. payment: t/t or letter of credit supply: 12 month Incoterm: FOB OR CIF
Origin : Brasil and Colombia calibers: size 42 to 60 cntr: 22 pallets (240 boxes) each boxes of 4.5 kg/pallet temperature cntr: 7 to 9 for transport and storage Certification: Global Gap and Grasp minimum: 4 pallets payment: t/t or letter of credit supply: 12 month Incoterm: FOB OR CIF
Blood Glucose monitor devices with biosensor : latest generation, extremely precise, reliable and easy to use. The test strips are not coded, in order to reduce the risk of mistakes due to incorrect settings. It is possible to make the measurement taking the blood from more sites in the body and not only from fingers. The devices can store a high number of measurements and they can calculate the average up to 90 days. The logic of the appliance allows the devices to be very easy to use as the measurements are made automatically. The most common mistakes are indicated: such as the usage in temperature conditions not suitable or like the reuse of already used test strip. The large and easy to read display also integrates the function of indicating the level of risk when the glucose values are out of optimal bounds. Sample: Capillary whole blood Dual-scale: mg/dl and mmol/l Blood sample size: 0.7 Î Measuring time: 6 seconds Measurement range: 20-600 mg/dl (1.1-33.3 mmol/l) Pressure accuracy: 20-60% Measurement memory with date and time: 500 Average calculation on days...: 7 / 14 / 21 / 28 / 60 / 90 Code free test strips. AST (Alternative Site Testing). PC interface. Hi-Low temperature alarm. Moistened or used strips alarm. Risk indicator. Automatic shut-off: 3 min. Large easy to read LCD display. Size / Weight with battery: 94 x 53 x 15 mm. / 49g Battery type / lifetime: CR2032 / 1000 measurements Notes: Technical specifications are indicative. All information contained in the website and in downloadable or visible online documentation related to medical devices have no character or nature of advertising. In any form they are made, all the contents have informative nature intended solely for pharmacists doctors and sector professionals. A different Warrantyperiod can be agreed with the company. NORDITALIA reserves the right to change technical, functional, performance and aesthetic specifications without notice.
Blood Glucose monitor devices with biosensor : latest generation, extremely precise, reliable and easy to use. The test strips are not coded, in order to reduce the risk of mistakes due to incorrect settings. It is possible to make the measurement taking the blood from more sites in the body and not only from fingers. The devices can store a high number of measurements and they can calculate the average up to 90 days. The logic of the appliance allows the devices to be very easy to use as the measurements are made automatically. The most common mistakes are indicated: such as the usage in temperature conditions not suitable or like the reuse of already used test strip. The large and easy to read display also integrates the function of indicating the level of risk when the glucose values are out of optimal bounds. Sample: Capillary whole blood Dual-scale: mg/dl and mmol/l Blood sample size: 0.7 Measuring time: 6 seconds Measurement range: 20-600 mg/dl (1.1-33.3 mmol/l) Acceptable hematocrit range: 20-60% Measurement memory with date and time: 250 Average calculation on days...: 7 / 14 / 21 / 28 Code free test strips. AST (Alternative Site Testing). PC interface. Hi-Low temperature alarm. Moistened or used strips alarm. Risk indicator. Automatic shut-off: 3 min. Large easy to read LCD display. Notes: Technical specifications are indicative. All information contained in the website and in downloadable or visible online documentation related to medical devices have no character or nature of advertising. In any form they are made, all the contents have informative nature intended solely for pharmacists doctors and sector professionals. A different Warrantyperiod can be agreed with the company. NORDITALIA reserves the right to change technical, functional, performance and aesthetic specifications without notice.
Product Description : Monoreinforced waterproofing membrane made up of a compound based on distilled bitumen modified withplastomeric polymers reinforced with non wovenpolyester fabric.The reinforcement provides good mechanicalproperties, while the special compound ensures highflexbility at low temperatures. Price of product ( USD price or FOB price) : 1,57 € ex works Italy - to be discussed with buyer Product Origin : Italy Key Specifications/special Features : Visible Defects Exceeds Visual - En 1850-1 Length 10 M -1 % En 1848-1 Width 1 M -1 % En 1848-1 Strainghtness Exceeds < 20mm/10m - - En 1848-1 Mass Per Unit Area 3 - 4 Kg/m2 - 5 % En 1849-1 Thickness 3 - 4 Mm - 0,2 En 1849-1 Watertightness Exceeds > 60 Kpa - En 1928:2000 Watertightness After Stretching Npd % - En 13897 External Fire Performance F Roof - - En 13501-5 Reaction To Fire E Classe - En 13501-1 Tensile Properties Maximum Load At Break Longitudinal Transversal 400 300 N/50 Mm - 20 % - 20 % En 12311-1 Elongation At Break Longitudinal Transversal 35 35 % - 15 In Ass. - 15 In Ass. En 12311-1 Resistance To Tearing (nail Method) Longitudinal Transversal 130 130 N - 30 % - 30 % En 12310-1 Resistance To Dynamic Loading 700 Mm = En 12691 Resistance To Stating Loading 10 Kg = En 12730-1 Cold Flexibility -5 °c En 1109 Flow Resistance At Elevated Temperature 120 °c En 1110 Dimensional Stability 0,3 % En 1107-1 Form Stability Under Cyclic Temperaure Change Npd Mm - En 1108 Artificial Ageing Behaviour (flow Resistance) Npd T °c - En 1296 Artificial Ageing Behaviour (visible Defects) Npd - - En 1297 Adhesion Of Granules Npd % - 5 In Ass. En 12039 Water Vapour Properties 20000 - En 1931 Resistance To Roots Npd - - En 13948 Peel Resistance Npd N/50 Mm - En 12316-1 Shear Resistance Npd N/50 Mm - En 12317-1 Minimum Order Size and Packgaing details : To be agreed - Normally full container 20 ft - 4400m2