Modular free standing enclosures Modular design Compact, space saving design Reduce space for storage and transportation High flexibility Designed according to customer needs Ability for future to extend Dimensions Height from 1500 mm up to 2200 mm Width from 400 mm up to 1200 mm Depth from 500 mm up to 800 mm Protection degree IP 54 Internal separation from form 1 up to form 4 Can be equipped with cable compartment Rated up to 4000A Design and assembled according to IEC 439-1 All routine tests are applied Polyester powder RAL 7032 or 7035 Incoming and outgoing feeder from top or bottom Applications Main distribution boards and sub main Motor Control Center Power Factor Correction ( PFC ) ATS panels As request 1 out of 2- 3 out of 5
(Panel design) Door of low-voltage compartment Opening for locking or un locking the low-voltage compartment door Option: Capacitive voltage detecting systemfor feeder and busbar High-voltage door Inspection window for checking the switchingdevice truck Opening for locking or unlocking the high-voltage door Opening for mechanical charging of circuit-breaker closing spring Openings for switchingdevice truck operation Opening for earthing-switch operation Pressure relief duct Busbars Bushings Post insulators Block-type current transformer Openings formanual operation (ON/OFF) of the circuit-breaker Inspection window for reading the indicators Door handle Option: Make-proof earthing switch Cable sealing ends Option: Voltage transformer Earthing busbar Low-voltage plug connector Vacuum interrupters Switching-device truck
Legend for panel design Door of low-voltage compartment Opening for locking or unlocking the low-voltage compartment door Option: Capacitive voltage detecting system for feeder and busbar High-voltage door Inspection window for checking the switchingdevice truck Inspection window for reading the indicators Door handle Openings for switchingdevice truck operation Opening for earthing-switch operation Pressure relief duct Busbars Bushings Post insulators Block-type current transformer Opening for locking or unlocking the high-voltage door Opening for mechanical charging of circuit-breaker closing spring Option: Make-proof earthin switch Cable sealing ends Option: Voltage transformer Earthing busbar Low-voltage plug connector Vacuum interrupters
â?¢ Our Ingots or Alloy made from bauxite ore (Primary). U.I.C DESIGNATION AA DESIGNATION DIN DESIGNATION AL.Si12 Cu(HI) 413.1 GB.AL.Si 12 (Cu) AL .Si12 (HI) 413.2 GB.AL.Si 12 AL.Si 12 413.2 GB.AL.Si 12 AL Si 10.Mg - GB.AL.Si 10 .Mg AL.Si 8.5 . Cu 3.5 380 GB . AL. Si 9 Cu3 AL.Si7 .Mg 356 GB.AL.Si 7.Mg H12 2332 - H13 412 GB.AL.Si 12 H13 . Cu 413.2 GB.AL.Si 12 AL . Si8 Cu (H10) B380.1 GB .AL.Si 9 Cu3 AL .Si 7 . Mg (H3) 356 GB.AL.Si 7 AL .Si 7 Mg .Sr 356 GB . AL . Si 7 Mg AL . Si 9 . Mg 364 GB . AL . Si 10 Mg AL . Si 11 . Mg 413.1 GB . AL . Si 11 AL . Si 11 . Mg . Sr 369 GB AL . Si11 AL.Si 13 413 - AL . Si 15 â?? 18 - AL . Si. 15 â?? 18 AS 6 GO3SB - AS 7 GO3SB â?? Analysis according to (U.I.C) Valid chemical Composition. â?? Other Alloys upon Customer's request. â?? OUR Designation according to AA, DIN for final aluminium product:- - Other alloys upon customer request. - Sr or Sb modified or non-modified. Physical Properties:- INGOT WEIGHT IN BUILDING OF BUNDLE WEIGHT 8 â?? 10 Kgs 89 Ingot One Ton Max 15 â?? 22 KGS 44 INGOT One Ton Max â?? SR or SB modified or non-modified Our Quality is Tested by : â?¢ Our modern quality control Laboratory consists of Optical Emission Spectrometer (OES). â?¢ Our manufacturing operations are producing aluminum foundry, billelts, slab, etc. are controlled round the clock by experienced Chemists & Q.A. Supervisors. â?¢ Our manufacturing operations are driven by quality, from the way they operate, to the customer service standards they set and the products they deliver. â?¢ Each heat is being analyzed prior to its pouring aluminum into the moulds to ensure proper chemistry, raw material size and dross content of our final product . All elements are controlled within specified limits and proper records are being maintained. Each heat is being assigned a unique batch no which is also marked every relevant ingot to ensure complete traceability at a later stage. â?¢ In addition to in-process inspection, a highly experienced and dedicated team ensures complete adherence to the most precise standards. Experts are involved right from choosing the highest quality raw material to application of various techniques to ensure the productâ??s confirmation to the highest quality standards. â?¢ We focus on quality, timely deliver and services which make us to win new opportunities in an increasingly competitive global marketplace. â?¢ We identify areas for improvement within our quality checks at every stage of manufacturing process to provide our customers with the best value possible in the products which we produce in our modern Plant. Proudly Made in Egypt. PAYMENT TERMS: L/C Irrevocable, confirmed, transferable, divisible, 100% at sight. F.F.D L/C (fully funded documentary letter of credit). DELIVERY TERMS: - CIF, FOB, &/OR C&F. â??Please feel free to send us your LETTER of material REQUESTâ?? or visit us unitedcoinc.com
Butyl Inner Tubes Scrap..
Welded mesh.Exporting, shipping
Aluminium composite panels.
Cooper scrap, plastic scrap.
Railway Scrap.
Heat exchangers, aluminium and cu/al coils.
Control Cables For Concrete Mixer And Earth Moving Equipments..
Aircraft Parts Scrap..
Solid coal tar pitch, anode grade green petroleum coke, quick lime, limestone, calcium carbide, fuel grade coke, aluminium fluoride, synthetic cryolite, carbon cathode blocks, cold ramming paste, calcined petcoke coke gor aluminium smelter.
Jumbo bag with liner scrap , pta purified terephthalic acid.
Lead ingots, detergent, food products, agricultural products, medical supply, metal, spices, sweets and candy, scrap , pp bags , jumbo bags , pa 06 , pa 66 , pvc ,.Import and export.
Automatic Voltage Regulator (AVR) AVR Automatic Voltage Regulator (AVR) with on Load Tap changer The On Load Tap Changer, automatic voltage regulator (AVR) is used to compensate the voltage drop in the electrical networkâ?? so that customers at the line end receive the same average voltage value as those closer to the source. The voltage value reduction affects the operational quality of the rotating machines and increases the losses due to the high current drawn due to the voltage reduction. It also affects the quality of the illuminating system. EGYTRAFO Group produces the Automatic Voltage Regulator (AVR) with rating up to 630 A & 9 tapping positions. -The AVR is flange mounted (ON TANK) or (IN TANK) type according to the rating of the transformer and a remote tap changer control cubicle (RTCC) Our ranges are up to 630 A, up to 22 KV and more than 5 taping positions on request. Automatic Voltage Regulator (AVR) applications: you can use it as a safely starting machines such as induction motors and synchronous motors Also, boosters to give a small boost to distribution cable for compensating the voltage drop you can get the same advantage of the Variac Automatic Voltage Regulator (AVR) advantages: Increased KVA rating for a given size and mass Less amount of copper Due to the smaller size, the cost is less compared to a two â?? winding transformer The resistance and reactance are less compared to a two â?? winding transformer and hence it has superior voltage regulation The Volt-ampere rating is more compared to a two â?? winding transformer It is possible to get a smooth and continuous variation of voltage