Organic castor oil cold pressed and heat pressed.
Coolants and antifreeze.
Product Description: Datex Ohmeda S/5 Aespire Clinician-inspired solutions help improve patient care Features - Enhanced monitor integration capabilities with our Datex-Ohmeda Anaesthesia Monitor and Compact Anaesthesia monitor - Lightweight and compact for easy manoeuvrability - Optional integrated auxiliary O2 flowmeter and suction control General Specifications: Dimensions - Height: 134.5 cm/52.9 in - Width: 72 cm/28.3 in - Depth: 73 cm/28.7 in - Weight: Approximately 108 kg/238 lb. Top shelf - Weight limit: 34 kg/75 lb. - Width: 66 cm/26 in - Depth: 40 cm/15.75 in Work surface - Height: 81.7 cm/32.2 in - Size: 2160 cm-2/334 in-2 DIN rail - Side of machine: 34.5 cm/13.6 in Drawers (internal dimensions) - Height: 17.5 cm/6.9 in - Width: 33 cm/13 in - Depth: 26.5 cm/10.4 in Absorber bag arm (optional) - Arm length: 30.5 cm/12 in - Bag arm height (adjustable): 87 cm (34.3 i) to 104 cm (40.9 in) Casters - Diameter: 12.5 cm/5 in - Brakes: Individual locking front casters Electrical Specifications Current leakage - 100/120 V: < 300¼A - Power - Power input: 100-120 Vac, 50/60 Hz - Power cord: Length: 5 m/16.4 ft. - Rating: 15A @ 120 Vac Inlet/outlet modules (120 V) - System circuit breakers: 15A - Outlets (optional): 4 outlets on back, 3-2A, 1-3A individual breakers, optional isolation transformer Pneumatic Specifications Auxiliary common gas outlet - Connector: ISO 22 mm OD and 15 mm ID Gas supply - Pipeline input range: 240 kPa to 600 kPa/35 psig to 88 psig - Pipeline connections: DISS-male, DISS-female, DIN 13252, AS4059, S90-116 or NIST (ISO 5359). All fittings available for O2, N2O, and Air, and contain pipeline filter and check valve. - Cylinder input: Pin indexed in accordance with CGA-V-1 or DIN (nut and gland); contains input filter and check valve Note: Maximum 3 cylinders; two inboard mounted, one outboard mounted. - Primary regulator diaphragm minimum burst pressure: 2758 kPa/400 psig - Primary regulator nominal output: < 338 kPa/49 psig Pin indexed cylinder connections - < 407 kPa/59 psig DIN cylinder connections Environmental Specifications System operation - Temperature: 10° to 40°C/50° to 104°F - Humidity: 15 to 95% relative humidity (non-condensing) per IEC 68-2-3 - Altitude: -440 to 3565 m/500 to 800 mmHg System storage - Temperature: -15° to 50°C/-5° to 122°F - Humidity: 10 to 95% relative humidity (including condensing) per IEC 68-2-3 - Altitude: -440 to 5860 m/375 to 800 mmHg - Oxygen cell storage: -15° to 50°C/5° to 122°F 10 to 95% relative humidity 500 to 800 mmHg Electromagnetic compatibility - Immunity: Complies with all requirements of EN 60601-1-2 - Emissions: CISPR 11 group 1 class B - Approvals: UL 2601-1 CSA C22.2 #601.1 EN/IEC 60601-1 CE 0197
Nitrile gloves, kn95 mask, n95 mask, latex gloves.Transportation and shipping
Teak, cedar, red oak, mahogany, eucalyptus, grevillea (from australian, "silk oak").Export, Shipping
Supplements like capsules and powders.Manufacturing and private label
Fossilized red guano fertilizer 100% organic.Logistics, shipping
Petroleum Products Such as Crude Oil, D2, D6, JP54, A1, EN590.Broker, Exporter
T Shirt, Caps, T Shirt Printing, Uniforms..
Sugar, soy, niobium, manganese.Trading, clearing, transportation and shipping
60 MW GE LM6000 PC Gas Turbine Power Plant 50 MW GE LM6000 PC gas turbine, Year of manufacture: 2011, Hours since new: 7000 hrs., 3000 rpm, 50 HZ, 13 MW Siemens SST 300 steam turbine, Year of manufacture: 2012, Hours since new: 5000 hrs, transformers, electrical systems, control systems, air system, cooling system, starting system, lubricating system, air compressors, HV System, MV System, LV System, ABB Pumps, Demi Water Systems, fire fighting system and much more. Complete plant in new condition, can be inspected in operation.
120 MW LM6000 PC Gas Turbine Power Plant 120 MW LM6000 combined cycle power plant consists of ( 2) 47 MW LM6000 PC Gas Turbines, Year 2007, 50 HZ, 11.5KV. HRSG, Steam Turbine, electrical systems, control systems, air system, cooling system, starting system, lubricating system, air compressors, demineralization unit, switch room, transformers, pumps and much more. The LM6000 PC gas turbine power plant is a complete plant that has been well maintained since installation on site. Can be seen in operation.
52 mw man diesel hfo complete power plant (7) 7600 kw man 16v32/40 sixteen-cylinder four-stroke, turbocharged and charge-air cooled engines, (7) heavy duty generators, year 2001, 750 rpm, 50 hz, only 7, 000 hours since installation, cooling system, lube oil system, lubricating oil system, control and monitoring system, electrical system, heavy fuel oil system, heavy fuel oil purification system: pumps, air system, exhaust gas system, compressed air system, heat recovery system, steam distribution system, boilers, transformers, tanks, tank farm equipment , water treatment, reverse osmosis system, desox system, start up boiler, fire fighting system, discharge pumps, water pumps, forced draft ventilation system, black-start-diesel generating set, piping, power house crane, hoist equipment and tools and spares. This is a complete plant that can be purchased a very good price.
52 mw man diesel hfo complete power plant (7) 7600 kw man 16v32/40 sixteen-cylinder four-stroke, turbocharged and charge-air cooled engines, (7) heavy duty generators, year 2001, 750 rpm, 50 hz, only 7, 000 hours since installation, cooling system, lube oil system, lubricating oil system, control and monitoring system, electrical system, heavy fuel oil system, heavy fuel oil purification system: pumps, air system, exhaust gas system, compressed air system, heat recovery system, steam distribution system, boilers, transformers, tanks, tank farm equipment , water treatment, reverse osmosis system, desox system, start up boiler, fire fighting system, discharge pumps, water pumps, forced draft ventilation system, black-start-diesel generating set, piping, power house crane, hoist equipment and tools and spares. This is a complete plant that can be purchased a very reasonable price.
105 MW Wartsila HFO Power Plant (7) 15.143 MW Wartsila 18 V 46 Four stroke, Direct Injected, Turbo Charged Heavy Fuel Engines and Generators, Commissioned 2001, 11000 V, 50 HZ, Engines were overhauled and have run between 400 hrs to 9000 hrs. Next overhaul is at 3000 to 11500 hours( depending on the engine) (3) Waste Heat Recovery Boilers:, Cooling system, Lube Oil system, Lubricating Oil System, Control and Monitoring System, Transformers, Electrical System, Pumps, Air System, Exhaust System, Compressed Air System, Tanks and much more. Plant can be purchased as a complete Turnkey Operation on your site if required.
Hill-Rom Advance 2000 Features:- - Fully Electric (Head/Knee/ Bed-Hi/Lo) - Complete w/ Head/Footboards & 4-Rails - Patient Controls on Head Side Rails (easy access) - Nurse Control Panel (w/ lock-out options) - Panel Mattress Surface - Integrated Air Mattress System - Central Brake & Steer (both sides) - Trendelenburg/ Reverse Trendelenburg - Sensor Controlled Nightlight - Service Pan - Drainage Bag Holders - IV Pole Storage - SideCom Nurse Controls - Removable Headboard for CPR - Emergency CPR Release - Bed Exit System (optional) - New Foam Mattresses Sold Separately - Scale - Dynamic Air Mattress Specifications: Hi-Lo Travel Time - 21 seconds Sleep Surface - 36" x 84" High Position - 30" Low Position- 17" Length - 93.5" Width - 41.5" Casters - 5" Weight capacity- 500 lbs.
Natural gas , petroleum gas, butane, aviation kerosene colonial grade jp54, diesel gas oil , gost 305 82 (diesel d2), mazut m100 gost, automotive gas oil, jet fuel (jp a1), diesel fuel, pet coke, bitumen, gasoline, crude oil, urea granular, diesel d6 virgin low pour fuel oil.
70 MW Wartsila Dual Fuel Power Plant This a complete plant that has Total Power:70840 K, Total Hot Water production :360 ton/h, Total Steam :35 ton/h, (6) six Wartsila Natural Gas and Dual Fuel Generator sets (4) 8730 kW Wartsila 20SV34SG Natural Gas Generator Sets, Year 2006 to 2009, 15000 to 40000 hours (2) 16650 KW Wartsila 50 DF Generator sets (Natural Gas, Light Fuel Oil & Heavy Fuel Oil) Year 2010, 11,000 running hours, 514 rpm, 50 HZ, Siemens Steam Turbine, Boilers, Cooling system, Lubricating Oil System, Control and Monitoring System, Electrical System, Transformers, Pumps, Air System, Exhaust Gas System, Compressed Air System, tanks and etc. The (2) 16650 KW Wartsila 50 DF Generator sets can be purchase separately from the rest of the plant.
80 MW Pratt & Whitney FT8 Combined Cycle Power Plant Two (2) 29 MW Pratt & Whitney FT8-3 Swiftpack single shaft gas turbines with air cooled brush generators, Fuel: Natural Gas (NG), 3000 rpm, 50 HZ, Hours: 16,000 hrs, commission in 2010, (2) Steam turbines, transformers, condensers, electrical systems, control systems, cooling systems compressor systems, starting system, lubricating system, fire fighting system and much more. Complete plant, can be inspected in operation.
200 MW Siemens SGT-800 Gas Turbine Power Plant Three (3) Siemens SGT 800 Gas Turbines, Siemens Steam Turbine, 3000 rpm, 50HZ, Commissioned Year: 2013, Total operating Hours, 21,000, Hours ran after last inspection 2500 hrs. (3) HRSG, RMS station, HV switchyard,, electrical systems, control systems, air systems, cooling systems, compressor systems, pumps, starting system, lubricating system, fire fighting system and much more. Complete plant, can be inspected in operation.