Non Ferrous Materials Like Brass, Copper , Aluminium , Bronze Etc.
Aluminum ingots, copper milberry, copper cathode, used rails, iron ore, zinc ore, all other metals & minerals.
Aluminum ingots, copper milbberry wire scraps, copper cathode, rail scraps, HMS1 & HMS2, iron ore, zinc ore, copper ore .Commodity trading, professional consultancy services etc
Aluminum die-cast power steering components such as rack housing, pinion housing and gear box .
Automobile Spares/Two Wheeler Spares, Sheet Metal Pressings, Machined Aluminium Die Castings Brakes.
Cocoa powder, timber, medical equipment and covid 19 essential product like ppe, medical laboratory instruments, nitrile examination gloves, hosiptal and diagnosis equipment, non powdered latex examination gloves, synthetic nitrile latex gloves, 3d medical mask, ame disposable non woven protective clothing, ame face shield, n95 and aluminum a7.
Carbide products, machinery spares, ingot moulds, heading dies, wire drawing dies, swagging dies, biogas cng plant, biogas bottling plants. mainly mfgr of ingot moulds made of dictlite iron.Import and exporter
All kind of stationery, paver moulds, PP ropes, led lights, groundnut, spices, maize, hardware items, all kind of paper products.Clearance
Car battery scrap, steel scrap, aluminium scrap and stainless steel scrap.
Steel washers, copper washers, brass washers, red fiber washers, acrylic washers, aluminium washers.
Product Details: Brand : Boditech Med Incorporated Size : 25 T Samples : Human serum/plasma/control Specimen volume : 50 Microliter stored at 4 - 30 DegreeC Cat No : CFPC-89 INTENDED USE : ichroma AMH is a fluorescence Immunoassay (FIA) for the quantitative determination of AMH (Anti-m�¼llerian hormone) in human serum/plasma. It is useful as an aid in management and monitoring of premature ovarian insufficiency, menopause and ovarian reserve.For in vitro diagnostic use only. COMPONENTS : ichroma AMH consists of cartridges, detectors and diluent The cartridge contains the membrane called a test strip which has streptavidin at the test line and chicken IgY at the control line. All cartridges are individually sealed in an aluminum foil pouch containing a desiccant in a box The detector has 2 granules containing anti human AMH-fluorescence conjugate, anti-chicken IgY-fluorescence conjugate, anti-human AMH-biotin conjugate, bovine serum albumin (BSA) and sucrose as a stabilizer, MAB33 as a blocker in Tris-HCl buffer. All detectors are packed in a box The diluent contains bovine serum albumin and NaCl as a stabilizer, tween 20 and CA-630 as a surfactant and sodium azide as a preservative in phosphate buffered saline (PBS), and it is pre-dispensed in a vial. The diluent is packed in a box. PRINCIPLE : The test uses a sandwich immunodetection method; the detector antibodies in buffer bind to antigens in the sample, forming antigen-antibody complexes, and migrate onto nitrocellulose matrix to be captured by the other immobilized-antibody on test strip.More antigens in sample will form more antigen-antibody complexes which lead to stronger fluorescence signal by detector antibodies, which is processed by instrument for ichroma tests to show human AMH concentration in the sample. INTERPRETATION OF TEST RESULT : The instrument for ichroma tests calculates the test result automatically and displays AMH concentration of the test sample in terms of ng/mL The working range: 0.02- 15 ng/mL
Product Details: Brand: Boditech Med Incorporated Size : 25 T Samples : human whole blood/serum/plasma Specimen volume ; 150 microliter stored at 4-30 DegreeC Cat No : CFPC-23-1 PCT Assessing initial risk of bacterial infection and fatal sepsis Diagnosis of sepsis is routinely performed in intensive care units (ICU) of all hospitals. Early detection of sepsis is very important in determining appropriate treatment as it is known to improve patient survival through a various therapeutic strategy for sepsis. The ichroma & AFIAS PCT test helps detect bacterial sepsis and assess the risk of developing septic shock. INTENDED USE : ichroma PCT is a fluorescence Immunoassay (FIA) for the quantitative determination of Procalcitonin (PCT) in human whole blood/serum/plasma. It is useful as an aid in management and monitoring of bacterial infection and sepsis. For in vitro diagnostic use only. PRINCIPLE : The test uses a sandwich immunodetection method; the detector antibody in buffer binds to antigen in sample, forming antigen-antibody complexes, and migrates onto nitrocellulose matrix to be captured by the other immobilized-antibody on test strip. The more antigen in sample forms the more antigen-antibody complex and leads to stronger intensity of fluorescence signal on detector antibody, which is processed by instrument for ichromaâ?¢ tests to show PCT concentration in sample. STORAGE AND STABILITY: The cartridge is stable for 20 months (while sealed in an aluminum foil pouch) if stored at 4-30 C. The detection buffer dispensed in a tube is stable for 20 months if stored at 2-8 C. After the cartridge pouch is opened, the test should be performed immediately. MATERIALS SUPPLIED : REF CFPC-23 Components of ichromaâ?¢ PCT Cartridge Box: - Cartridges 10 - ID Chip 1 - Instruction For Use 1 Box containing Detection Buffer tubes - Detection Buffer Tubes 10
Product Details: Brand : Boditech Med Incorporated Size : 25 T Specimen : human serum/plasma Specimen volume : 50 Microliter Cat. No. : CFPC-47 INTENDED USE : ichromaâ?¢ Vitamin D is a fluorescence Immunoassay (FIA) for the quantitative determination of total 25(OH)D2/D3 level in human serum/plasma. It is useful as an aid in management and monitoring of regulating the concentration of calcium and phosphate in the bloodstream and promoting the healthy growth and remodeling of bone.For in vitro diagnostic use only. PRINCIPLE : The test uses a competitive immunodetection method. In this method, the target material in the sample binds to the fluorescence (FL)-labeled detection antibody in detection buffer, to form the complex as sample mixture. This complex is loaded to migrate onto the nitrocellulose matrix, where the covalent couple of 25(OH)D3 and bovine serum albumin (BSA) is immobilized on a test strip, and interferes with the binding of target material and FL-labeled antibody. If the more target material exists in blood, the less detection antibody is accumulated, resulting in the less fluorescence signal. STORAGE AND STABILITY : The cartridge is stable for 20 months (while sealed in an aluminum foil pouch) if stored at 4-30 C. The detection buffer dispensed in a vial is stable for 20 months if stored at 2-8 C. The releasing buffer dispensed in a vial is stable for 20 months if stored at 2-8 C. Opened detection buffer and releasing buffer are stable for 12 months at 2-8 C if kept capped in original container and free from contaminations. After the cartridge pouch is opened, the test should be performed immediately. MATERIALS SUPPLIED : REF CFPC-47Components of ichroma Vitamin D Cartridge Box:- Cartridges 25- Sample Mixing Tubes 25- ID Chip 1- Instruction For Use 1 Detection Buffer Vial (3 mL) 1 Releasing Buffer Vial (2 mL) 1
Product Details: Brand : Boditech Med Incorporated Size : 25 T Samples : Human whole blood/serum/ plasma Sample volume : 50 Microliter stored at 4 - 30 DegreeC Cat No : CFPC-65 Troponin I (Tn-I) Plus Early diagnosis of myocardial infarction with high sensitivity Troponin I (Tn-I) Plus can diagnose myocardial infarction and myocardial necrosis at an early stage with high sensitivity by accessing Tn-I level in the blood, thus can help prevent progression to more severe cases. INTENDED USE: ichroma Tn-I Plus is a Fluorescence Immunoassay (FIA) for the quantitative determination of cardiac troponin-I (Tn-I) in human whole blood/serum/plasma. It is useful as an aid in management and monitoring of acute myocardial infarction (AMI). For in vitro diagnostic use only. PRINCIPLE : The test uses a sandwich immunodetection method; the detector antibodies in buffer bind to antigens in the sample, forming antigen-antibody complexes, and migrate onto nitrocellulose matrix to be captured by the other immobilized-antibodies on test strip. More antigens in the sample will form more antigen-antibody complexes which lead to stronger fluorescence signal by detector antibodies, which is processed by instrument for ichromaâ?¢ tests to show Tn-I concentration in the sample. MATERIALS SUPPLIED : REF CFPC-65 Components of ichroma Tn-I Plus Cartridge Box: - Cartridge 25 - 50L Capillary tube 25 - ID chip 1 - Instruction for Use 1 Buffer Box For ichorma II - Detector (Capped with plastic lid) 25 - Diluent 1 For ichroma 50 - Detector (Sealed with aluminum foil) 25 - Diluent 1
Product Details: Brand : Boditech Med Incorporated Size : 25 T Samples : human whole blood/serum/plasma Specimen volume : 5 Microliter stored at 4-30 C Cat No : CFPC-51 Anti-CCP Plus Supporting to distinguish and diagnose rheumatoid arthritis This test helps to diagnose and provide appropriate treatment for chronic systemic autoimmune diseases and rheumatism by quantifying Anti-CCP in the blood. INTENDED USE : ichroma Anti-CCP is a fluorescence Immunoassay (FIA) for the qualitative or semi-quantitative determination of human IgG autoantibodies to cyclic citrullinated peptides (CCP) in human whole blood/serum/plasma. It is useful as an aid in the diagnosis of rheumatoid arthritis (RA) in combination with other clinical and laboratory findings. For in vitro diagnostic use only. STORAGE AND STABILITY : The cartridge is stable for 20 months (while sealed in an aluminum foil pouch) if stored at 4-30 C. The detection buffer dispensed in a tube is stable for 20 months if stored at 2-8 C. After the cartridge pouch is opened, the test should be performed immediately. PRINCIPLE : A synthetic cyclic citrullinated peptide (CCP) is immobilized on a porous membrane. After a sample is added to the sample port, detection buffer, consisting of fluorescent conjugated polyclonal antibody to human IgG, is loaded to the buffer port. The more anti-CCP antibodies in sample forms the more the peptide antigen/anti-CCP antibodies complex and leads to stronger intensity of fluorescence signal on detector anti-human IgG, which is processed by instrument for ichroma tests to show anti-CCP level in sample. MATERIALS SUPPLIED : REF CFPC-51 Components of ichroma Anti-CCP Cartridge Box: - Cartridges 25 - Sample collectors 25 - ID Chip 1 - Instruction For Use 1 Box containing Detection Buffer Tubes - Detection Buffer Tubes 25
Copper millberry, copper cathodes, aluminum ingots, power tools and rice bran. trader..
we can supply Upvc Doors And Windows (we use german profiles we aluminum door and windows. we complet manufacturing facility equipped with all germany made machine all size , 20 ft container
Housekeeping, Office Stationery, Packing Materials, Tissue, Board Stuff.
.Casting cum machining & aluminum forging.
Aluminum casting ingot, steel casting, cast iron casting.Maintenance job, exporting