Electronic equipments, calculators, computers, T.V., inks, scanners
Diesel fuel en590, gasoline 91/95 octane, crude oil, white kerosene oil, carbon steel pipes, stainless steel pipes, stainless steel fittings, carbon steel fittings, forged carbon steel fittings, forged stainless steel fittings, malleable iron fittings, galvanized malleable fittings, forged carbon steel flanges, forged stainless steel flanges, forged carbon steel valves, forged stainless valves, for electrical fittings rigid & pvc coated, for welding solutions, for industrial safety equipments, power tools, tools, consumables, valves, pipe tools tech, p.p.e, hoses, fasteners & fitting, gaskets, pipes, filters, hand tools, pvf, ups, control panel, pumps & motors , bearing & other industrial material.
The buyer would like to receive quotations for -
Product Name : Solar Thermal Power Collector
Specifications :
Average Solar Absorbtance (ASTM)
a = 0.960 (95.5%)
Average thermal emittance (400C) e = 0.095 (9.5%)
Steel tube outer diameter 70 – 90 mm
Wall thickness 2.0 – 3.0 mm
Length (at 20C ambient temperature) 4.060 mm
Vacuum Residual gas pressure = 10-4 mbar
Glass envelop Borosilicate glass
Outer diameter 125 – 145 mm
Antireflective coating = 95.0% of aperture length
Average solar transmittance t = 0.970 (97%)
HTF Water
Operating pressure = 30 bar
Operating temperature = 400C
Concentration ratio C less than 100
Quantity Required : MOQ
Shipping Terms : CIF
Destination Port : Aqaba, Jordan
Payment Terms : To be discussed with suppliers
Looking for suppliers from : Worldwide
Contact : Eng. Rami Abu Hashhash
Buyer is interested to receive quotations for the following RFQ -
Product Name: Hospital Equipment
Specifications :
1: Hot And Cold Food Trolleys, With Trays
Safety Standard: FDA Approval Or CE Marking
External Trolley Structure: Antibacterial Material PVC, Stainless
Steel
Internal Structure: Stain Less Steel 304 (thickness 1.2- 2)
Compartments Fully Insulated
Antistatic Handles And Castors
Tray Holder
Doors Open 270° And Are Complete Self-closing Doors
Capacity Minimum 16 Trays Each Compartment
Approximate Dimensions: L1250mm X W800mm X H1500mm
Manual Driven
4 X 150mm Dia Heavy Duty Non Marking Precision Castors, 2
Swivel With Brakes And 2 Fixe
Independent Temperature Control
Temperature Alarms, Cooling Or Heating Systems Failure Alarms.
Quantity Required : 1 Twenty-Foot Container
Shipping Terms : CIF
Destination Port : Jordan
Payment Terms : To be discussed with sellers
Looking for suppliers from : Worldwide
Contact : Murad
Please provide a quotation to the following requirement from importer -
Product Name: Voltage Regulator
Specifications:
Details :
1. set Of 10mva(200a) Open Delta Voltage Regulator Unit , 33 Kv With
± 10% Regulation, Complete With
Control Panel And All Accessories As Mentioned In Our Requirements set 1
Technical Specifications
1. scope
This Standard Specifies The Requirements For Automatic Voltage Regulators For Use On Ohl 33kv Electricity Distribution Network.
2. system Parameters
(a) nominal Voltage - 33kv
(b) system Highest Voltage - 36kv
(c) system Frequency - 50hz
(d) number Of Phases - 3
(e) method Of Earthing - Resistance
(f) system Fault Current - 25 Ka
3. service Conditions
(a) annual Average Ambient Temperature: 30oc
(b) maximum Ambient Temperature: 50oc
(c) maximum Relative Humidity: 90%
(d) environmental Conditions: Tropical Climate.
(e) operational Altitude: From 400 M Under Msl To 1400m Above Msl
4. standard Regulator Operating Condition
(a) the Temperature Rise Of Top Oil At Cmr Above Specified Design Ambient Shall Be 50oc.
(b) the Temperature Rise Of Windings At Cmr Above Specified Design Ambient Temp Shall Be 55oc.
5. application Standard
This Standard Makes Reference To The Following Documents Or Any Equivalent International Standards:
• ieee Std C57.15 Standard Requirements, Terminology, And Test Code For
• step-voltage Regulators.
• iec 60296 Insulating Oil For Transformers And Switchgears.
• iec 60076 Power Transformers.
• bsi Bs 381c Specification For Colors For Identification, Coding, And Special Purposes.
• bsi Bs En Iso 1461- Hot Dip Galvanized Coatings On Iron And Steel Articles.
• bs 2562 Specifications For Cable Boxes For Transformers And Reactors.
• bs 3692 Iso Metric Precision Hexagonal Bolts, Screws& Nuts.
• bs 4190 Iso Metric Black Hexagonal Bolts, Screws And Nuts.
• bsi Bs 7079 Surface Finish Of Blast Cleaned Steel For Painting.
• iec 60529 Specification For Degree Of Protection Provided By Enclosures.
• bs 5493 Code Of Practice For Protective Coating Of Iron And Steel Structures Against Corrosion.
• iec 60076-10 Method Of Measurement Of Transformer And Reactor Sound Levels.
• iec 60076-7 Loading Guide For Oil Immersed Power Transformers.
As Per Moq
Quantity Required : MOQ
Shipping Terms : CIF
Destination Port : Aqaba, Jordan
Payment Terms : LC/TT
Looking for suppliers from : Worldwide
Contact : Ramzi Saba
Buyer is interested to receive quotations for the following RFQ -
Product : Hospital Equipment
Specifications:
1: Hot and Cold Food trolleys, with trays.
Safety standard: FDA approval or CE marking
External Trolley structure: antibacterial material PVC, stainless
steel
Internal structure: Stain less steel 304 (thickness 1.2- 2)
Compartments fully insulated.
Antistatic handles and castors
Tray holder
Doors open 270° and are complete Self-closing doors
Capacity Minimum 16 trays each compartment
Approximate Dimensions: L1250mm X W800mm X H1500mm
Manual Driven
4 x 150mm dia heavy duty non marking precision castors, 2
swivel with brakes and 2 fixe
Independent temperature control
Temperature Alarms, cooling or heating systems failure alarms.
5 pcs quantity
2: Linen/Laundry Trolleys
Safety standard: FDA approval or CE marking
Stainless steel cart with shelves to transport clean linen.
Swivel castors with brakes.
All needed accessories: Included
15 pcs quantity
Linen/Laundry Hampers with two bags
- Safety standard: FDA approval or CE marking
- All stainless-steel tubular pipe frame.
Mounted on 4 x 100mm swivel castors, 2 fitted with brakes.
Supplied with Canvas/CCF Bag and tie strings.
Push handle.
- Dimensions: Approx.1070 x 460 x 1070 mm ( L x B x H).
- All needed accessories: Included
35 pcs quantity
4: Specimen storage cabinets
- As per OSHA and NFPA standards
- FDA approval or CE marking
- 34”L x 30”D x85”H All stainless steel cabinet construction.
- Key lock included.
- Adjustable shelves, approx. weight per shelf 200Lbs.
- Spill-catcher galvanized steel shelves catch incidental drips.
- High-performance, sliding, self-latching doors, closes easily
and securely for maximum protection under fire conditions.
- Fail-safe closing mechanism
- All needed accessories: Included
2 pcs quantity
5: Chemical Safety Cabinet
- FDA approval or CE marking.
- 3- tray-shaped shelves adjustable in height by racks, with
bottom basin, made of electrogalvanized steel painted with
epoxide acid-proof dusts.
- Shelf loading: 100 kg
- Two Doors, each opening up to 110”
2 pcs
6:Wall-Mount Digital Temperature & Humidity indoor
Thermometer for storage areas.
CE Marked, NIST traceable , or RoHs, or WEEE.
All needed accessories: Included
10 pcs
the above quantities are an immediate requirement - closing on 9th july
Quantity Required : MOQ
Shipping Terms : CIF
Destination Port : Jordan, Jordan
Payment Terms : To be discussed with suppliers
Looking for suppliers from : Worldwide
Contact : Sinan Almaraghi/ Murad
Please quote for the following wholesale product requirement -
Product Name: Repair Clamps
Specifications:
Bands
Nominal Pipe Size (Inch)
Pipes Material Type
Length (mm)
No. bolts
Single Band 2
HDPE
3500
150 2
3
DI
150
150
2
4
DI
1000
150
2
5
HDPE
1000
150
2
6
DI
200
200
3
Double Bands
8
DI
25
300
3*
1. SCOPE
This Specification specifies the requirements for the design, materials and in-service performance of mechanical stainless steel repair clamps for waterworks purposes.
This Specification is designated for applications involving rigid pipes, typically ductile iron (DI), grey cast iron (CI), and steel (S). Also, for applications involving flexible pipes, typically un-plasticized polyvinylchloride (PVC-U) and high-density polyethylene (HDPE).
All materials and Equipment shall be in every respect suitable for storage, installation, use and operation in the conditions of temperature, humidity and The PH and water quality appertaining in Jordan.
The atmospheric temperature in Jordan varies between -10 C and 50 C.
2. Application
Stainless steel repair clamps complying with this specification are intended for use in repair of water supply pipelines of the size designated in Table 1, with a maximum service temperature of 50°C and up to an allowable operating pressure of 16 bars for ranges diameter up to 250 mm and 10 bar for diameters larger than 250 mm. Repair clamps have limited ability to accommodate axial deflection and are, therefore, not generally intended for use as couplings to join tow pipes together. However, they are commonly utilized for repair situations at full pipe break, where the pipe ends are considered stable. In addition, repair clamps complying with this specification are intended to provide a permanent means of preventing loss from or contamination of pipelines that have been affected by corrosion or mechanical damage in both above-ground and buried applications.
3. Materials
The material of the Clamps shall be
Bands: Stainless Steel Grade AISI 304(A2) to BS1449:1991: part 2 or Grade AISI 316(A4) stainless steel to BS 1449:1991:part 2, for corrosion resistance.
Bolts shall be Stainless Steel A2, Teflon coated, or mild steel. Nuts & washers shall be Stainless Steel A2, or mild steel class 4.6 to BS EN20898: Part 1. Receiver bars shall be TIG- welded to shell to form strong fusion, and fully passivated after welding,
Gasket shall have a gridded pattern for positive sealing, and to be made of specially compounded NBR rubber specially formulated for water service or EPDM. Compound Grade E to BS2494:1990
4. Design
The Clamps shall be used for permanent repair of cracks, holes, or complete breakages of steel, ductile Iron, PVC and HDPE pipes.
The Clamps shall be suitable for potable water for Temperature range (-10 to 50) C. potable water certificate must be submitted .
Repair Clamps shall be standard full circle single band for diameter 150mm or less. And full circle double band for diameter more than 150mm, length and number of bolts not less than the values in Table 1 for each diameter.
Gasket shall provide a 360o sealing surface and of such size and shape to provide an adequate compressive force against the pipe after assembling to affect a positive seal under all combinations of joint and gasket tolerances. And heavy gauge Type 304 stainless Steel bridge plate shall be attached into the gasket end to span the lug area and to make installation quick and easy.
Bolt retainer assembly or lugs shall be of a type 304 stainless steel, and shall be MIG welded to receiver bar and fully passivated after welding. Lugs may be cast, forged or cold formed of type 304 stainless steel, and may include a high impact polycarbonate plastic, non corrosive retainer. Lug design shall
Quantity Required : MOQ
Shipping Terms : CFR
Destination Port : Aqaba, Jordan
Payment Terms : LC
Looking for suppliers from : Worldwide
Con
Mechanical power transmition: motors, coupling, chains, gear motor, v-belts, pulleys, machines and machines tools: drilling, grinding, crushing & cutting machines, CNC and DNC, milling and lathe machines, cutting, milling, reaming and threading tools, piping system & auxiliary, pipes: seamless & welded, C/ steel, st. St., alley steel & plastic, fitting: seamless & welded, c/ steel, st. St., alley steel, plastic &forged flanges, expansion joints: metallic, rubber, rectangular & special made expansion joints, hoses: pneumatic, hydraulic, industrial, rubber, metallic & plastic, steam traps & strainers ( straight & y- type) thermal insulator & refractory materials, bricks : basic, acid, neutral, castable materials, ceramic blocks, ferrules, high temperature insul
Please provide a quotation to the following requirement from importer -
Product Name: GI Fittings
Specifications :
Item Description Qty Unit
1 GI Coupling 1/2" Weldable 1,500 Ea (10pcs/Bag)
2 GI Coupling 3/4" Weldable 1,500 Ea (10pcs/Bag)
3 Weldable 1" Coupling GI 1,000 Ea (10pcs/Bag)
4 Weldable 2" Coupling GI 500 Ea (5pcs/Bag)
5 GI Union Joint 1/2" 200 Ea (10pcs/Bag)
6 GI Union Joint 3/4" 1,000 Ea (10pcs/Bag)
7 GI Union Joint 1" 1,000 Ea (10pcs/Bag)
8 GI Union Joint 2" 500 Ea (5pcs/Bag)
9 GI Nipple 1/2" 25,000 Ea (10pcs/Bag)
10 GI Nipple 3/4" 33,000 Ea (10pcs/Bag)
11 GI Nipple 1" 5,00 Ea (10pcs/Bag)
12 GI Nipple 2" 1,000 Ea (5pcs/Bag)
13 GI Reducer 3/4" x 1/2" 20,000 Ea (10pcs/Bag)
14 GI Reducer 1" x 1/2" 1,000 Ea (10pcs/Bag)
15 GI Reducer 1" x 3/4" 6,000 Ea (10pcs/Bag)
16 GI Reducer 2" x 3/4" 200 Ea (5pcs/Bag)
17 GI Reducer 2" x 1" 200 Ea (5pcs/Bag)
18 GI Tee 1/2" 200 Ea (10pcs/Bag)
19 GI Tee 3/4" 4,000 Ea (10pcs/Bag)
20 GI Tee 1" 500 Ea (10pcs/Bag)
21 GI Tee 2" 100 Ea (5pcs/Bag)
22 GI Tee Reducer 3/4" x 1/2" x 3/4" 4,000 Ea (10pcs/Bag)
23 GI Tee Reducer 1" x 1/2" x 1" 1,000 Ea (10pcs/Bag)
24 GI Cross 3/4" 500 Ea (10pcs/Bag)
25 GI Cross 1" 500 Ea (10pcs/Bag)
26 GI Elbow 1/2" 1000 Ea (10pcs/Bag)
27 GI Elbow 3/4" 15,000 Ea (10pcs/Bag)
28 GI Elbow 1" 3,500 Ea (10pcs/Bag)
29 GI Elbow 2" 500 Ea (5pcs/Bag)
30 GI Reducer Elbow 1" x 1/2" 100 Ea (10pcs/Bag)
31 GI Reducer Elbow 3/4" x 1/2" 250 Ea (10pcs/Bag)
32 GI plug 1/2" with a hole 4,500 Ea (10pcs/Bag)
33 GI plug 3/4" with a hole 1,000 Ea (10pcs/Bag)
34 GI plug 1" with a hole 1,000 Ea (10pcs/Bag)
35 GI plug 2" with a hole 500 Ea (5pcs/Bag)
Galvanized Iron Fittings specifications
1.1 Ambient Conditions
All Fittings, materials and Equipment shall be in every respect suitable for storage, installation, use and operation in the conditions of temperature, humidity and The PH and water quality appertaining in Jordan.
The atmospheric temperature in Jordan varies between -10°C and 50 °C.
1.2 Potable Water Certification
All Fittings and materials shall be certified for potable water use, and all fittings and materials should be certified as safe for transporting potable water by an independent testing laboratory. All material in contact with or likely to come into contact with water for public shall introduced with the requirements of BS 6920 (suitability for non metallic products for use in contact with drinking water) or any equivalent standard as well as the Jordanian standard (JS 286/2008) and the requirements of EN 15664 ( influence of metallic materials on water intended for human consumption ) or any equivalent standard and the World Health Organization standard (WHO), and whenever the regulation is changed it is the supplier responsibility to ensure conformity with any new requirements..
1.3 Toxic Materials
Fittings and components, including their protective coatings and joint materials, that will or may come into contact with potable water shall not constitute a toxic hazard, shall not support microbial growth, shall not cause taste or odour, cloudiness or discoloration of the water and shall contain no ingredients that may migrate into water in amounts that are considered to be toxic or otherwise dangerous for health Non toxicity certificate should be provided.
1.4 Third Party Witness
The supplier must submit at least 3 different international third party companies where Miyahuna will choose one of them.
The supplier shall furnish an original certificate from a third party inspection agency showing all test resu
Quantity Required : MOQ
Shipping Terms : CFR
Destination Port : Aqaba, Jordan
Payment Terms : LC
Looking for suppliers from : Worldwide
Contact : Ramzi Saba
The buyer would like to receive quotations for -
Product Name: Pond Water Circulation Pumps And Vacuum Pumps
Specifications :
Pond Water Circulation Pumps And Vacuum Pumps
The Basins Are Constructed According To Code 937 And Operate On Site Electricity General (circulation And Drain Pumps) Ip 54 And Price Includes The Following
All Necessary Parts For Connecting The Pump To The Water Network Separation Valves And Valves Before And After The Pump And The Necessary Flanges And The Returns After The Pump And Inside The Water Intake Source And Filters And Flexible Connections, Pipes And Other Parts Necessary For Operations Installation.
Dry Run Low Level And Control Pressure Switches
Electric Supply To The Pump And From The Nearest Electrical Source Only What Is On The Electrical Diagrams.
Appropriate Concrete Bases And Appropriate Vibration Isolation Bases Inertia Base
Operation And Control Panel For Piston Pumps Operation, Extinguishing, Contactors, Overloads, And Signal Bulbs With All The Necessary Electrical Extensions Such As Wires, Pipes And Cans For Connection From The Operation Panel To The Pumps :
Pump Capacity 5.4l/sec, 70m Pressure (cp-l1-01) (three Working And One Spare) Number =4
Pumps With A Capacity Of 4.15 Liters Per Second, 46 Meters Of Pressure (cwp-l1-01) (two Working And One Spare) Number= 3.
And Another Type Of Pump If It Available For You Please Provide Us With Price
Submersible Pump For Pumping Water From Manholes (sewage Pump)
Construction Of Stator And Housing: Heavy Duty Cast Iron With Epoxy Paint.
Shaft: Stainless Steel.
Screws And Bolts: Steel.
50 Hz. – Single Phase.
Horizontal Outlet.
Operation Temperature From Oc – 40c.
Electrical Float Switch.
Electrical Power Cable (5)m Length One Piece Water
Proof. And High Quality Insulation.
Heavy Duty Ball Bearing And Permanently Lubricated
For Long Operating Life.
Brass Or Cast Iron Isolating Valve.
Suitable Hook Or Eye Bolt As Specified From The
Manufacture With Stainless Steel Lifting Cable, With A
Shackle.
Elbows And Flanges Shall Be Form Cast Iron.
All The Caskets Needed As Specified From The
Manufacture.
Easily-removed And Serviced Motor.
Oil Filled Or Air Filled Motors
Supplied With Thermal Protection.
Low Velocity (rpm) Is Preferable.
Hdpe Piping To Nearest Sub Lake As Per Drawing
2.0L/sec pump capacity, 12m pressure (SMP-1) number = 2
Quantity Required : MOQ
Shipping Terms : CIF
Destination Port : Aqaba, Jordan
Payment Terms : LC
Looking for suppliers from : South Korea (Republi, Philippines
Contact : Eng. Aya