The buyer would like to receive quotations for -
Product Name: Dc Car Wash Pressure Pump
Quantity Required : 10 Piece/Pieces(sample)
Shipping Terms : CIF
Destination Port : Riyadh Port, Saudi Arabia
Payment Terms : Bank Transfer
Looking for suppliers from : Worldwide
Contact : Imran
Windshield Repair Kit
Dc Car Wash Pressure Pump
Please provide a quotation to the following requirement from importer -
Product: Automatic Glue-Spraying Machine For Tires
Specifications:
Automatic Glue-Spraying Machine
Leak-proof area: tread, shoulder and sidewall of tire
Diameter of sharp objects: 8mm, Length 100mm
Thickness of glue which spray on tire: 3 ±0.5mm of tread, 2mm of shoulder and side wall
Dynamic unbalance of tire: 0.7% of tire weight
Temperature range: -30°C-100°C
Quantity Required : MOQ
Shipping Terms : CIF
Destination Port : Saudi Arabia
Payment Terms : LC
Looking for suppliers from : Worldwide
Contact : Mohammed Skaik
Please quote for the following wholesale product requirement -
Product Name: Portable Air-Sealed Car Wash Spray Inflatable Paint Booth Tent
Specifications:
Type : Portable Air-sealed car wash spray inflatable paint booth tent with filter garage mobile inflatable truck square bubble tent
Size:Customized
Quantity Required : MOQ
Shipping Terms : CIF
Destination Port : Saudi Arabia
Payment Terms : Bank Transfer
Looking for suppliers from : Worldwide
Contact : Lubnah Syed
Mechanical and maintenance parts etc.
Steel drums
Textile product, furniture/wooden products industrial cleaning products & chemical solutions, bathroom cleaners & kitchen cleaners, surface cleaners , degreasers, oil and stain removers, mold cleaners, disinfectants, hand sanitizers, maintenance chemicals, laundry hygiene products bulk commodities like cement, coal, iron & steel, grain etc construction & heavy machinery products
Please provide a quotation to the following requirement from importer -
Product Name: SS Finish Dual Swing Leaf Door
Specifications:
Spec with qty :
SS Finish Dual Swing Leaf Door 40MM Thick, 1100MM x 2100MM (Opening), Spring Hinges, Vision Panel 500x600MM 7.00Nos
SS Finish Single Leaf PU Core Door 40MM Thick 1000MM x 2100MM (Opening) With Door Closer. Swing Right Hand Reverse.
With Acess Control Lock 1.00 Nos
Supply and Installation Stainless Steel 316 Framed,
Fixed Poly Carbonate Sheet window 1600MM x 3500MM(H) 4.00 Nos
SS Double Leaf Hinged Door with Vision Panels, Door Closers, Airtight Gaskets, 40MM PU Core, Latches, Heavy Duty Handles, Digital Access Control Lock, Open to Outside. Opening 1500MM(W) x 2100MM(H)
1.00 Nos
Quantity Required : 13 Piece/Pieces
Shipping Terms : CIF
Destination Port : Saudi Arabia
Payment Terms : Bank Transfer
Looking for suppliers from : Worldwide
Contact : Abdul Jaber
Please quote for the following wholesale product requirement -
Product Name: LPG Tank
Specifications:
Double wall Tanks
Aboveground LPG Tank - 42,900 liters (2 units) ASME Standards, UL Listed 142, 2085.
1. Gas tank to be UL listed complete with Double skin configuration. Tank Capacity 42,900 Litres.
2. The Gas tank is located external to the building and Aboveground . The pipe work runs through Aboveground and enters the building at ground floor and distributes to the point of use with pipe in pipe protection. The complete installation shall be in compliance with NFPA.
3. Containers shall be designed, fabricated, tested and marked using criteria which incorporate an investigation to determine that it is safe and suitable for the proposed service, is recommended for that service by the manufacturer and is acceptable to the authority having jurisdiction.
4. Containers shall be designed, fabricated, tested and marked (or stamped) in accordance with the Regulations of the U.S. Department of Transportation (DOT), the â??Rules of the Construction of Unfired Pressure Vesselsâ??, Section VIII, Division 1, ASME Boiler and Pressure Vessel Code, or the API-ASME Code for Unfired Pressure Vessels for Petroleum Liquids applicable at the date of manufacture or BS 5500.
5. Containers showing serious denting, bulging, gouging, or excessive corrosion shall be removed from service. Repair or alteration of containers shall comply with the Regulations, Rules or Codes under which the container was fabricated. Welding is permitted only on saddle plates,legs or brackets attached to the container by the container manufacturer.
6. The minimum design, or service, pressure of DOT specification containers shall be in Accordance with the appropriate DOT regulations
7. Containers shall be designed to be self-supporting without the use of guy wires and shall satisfy proper design criteria taking into account wind, seismic (earthquake) forces, and Hydrostatic test loads.
8. Tanks should be supplied with means of security, protection and control in accordance with standards specified by Saudi Civil Defence/NFPA-58 and should comply with all standards and special requirements for public safety adopted by Saudi local requirements.
Quantity Required : 2 Unit/Units
Shipping Terms : CIF
Destination Port : Saudi Arabia
Payment Terms : Bank Transfer
Looking for suppliers from : Worldwide
Contact : Abdul Aziz
Steel products: sheet steel, reinforcing armature, blanks, tubes/pipes and etc.
Condition Monitoring Tools, Maintenance Tools And Materials, Predictive Maintenance Tools
Titanium tubes heat exchangers
Bitumen
3-ply-surgical-masks
Anti slip carpets, rugs, runners, door mats in different shapes like round, oval, d shape
3-ply-face-mask
Sawn timbers( kwila, rose wood and vitex), pallets
Pneumatic staple pins
Medical dental spare parts