Buyer is interested to receive quotations for the following RFQ -
Product Name: Electric Heaters
Specifications:
Room Machine Electric Heaters
Type Oil heater Installation Floor-standing
Recommended room area 27 m² Quantity
sections 11 Heating Heating power 2500 W
Mechanical Power Adjustment Wheels for
movement; Handle for moving; Compartment for network
cord; Power indicator Housing material metal
Dimensions and weight Height 55 cm Width 48 cm Thickness 25 cm
Weight 7.6 kg
Qty : 30 Units Initially
Quantity Required : 30 Unit/Units
Shipping Terms : CIF
Destination Port : Kazakhstan
Payment Terms : LC
Looking for suppliers from : Worldwide
Contact : Vladimir Igilmanov
Steam and hot water boiler, water boiler
Electric heaters
Plate Heat Exchanger, Electric Boiler
Spare parts for induction furnaces
Please provide a quotation to the following requirement from importer -
Product : Motor Resistor
Specifications:
Type : AC Heater Blower
Use :60049968 077800-0750 Excavator AC Heater Blower Motor
Qty : MOQ, Later More
Quantity Required : MOQ
Shipping Terms : FOB
Destination Port : Kazakhstan
Payment Terms : Bank Transfer
Looking for suppliers from : Worldwide
Contact : Yerbol Sadykov
Please quote for the following wholesale product requirement -
Product Name: SF6 Circuit Breaker
Specifications:
Characteristics
Rated voltage, kV: 110
Maximum operating voltage, kV: 126
Rated current, A: 3150
Rated breaking current, kA: 50
Thermal resistance current, kA (s): 50 (3)
Own shutdown time, ms: 35
Total shutdown time, ms: 55
Own turn-on time, ms: 62
Additional requirements :
light gray insulation
Additional cylinder with SF6 gas - 1 pc.
Gas filling kit - 1 pc.
Sensor gas leak detector T2 SF6 - 1 pc
Device for measuring gas humidity - 1 pc.
Racks brand H-678 mm
The drive has been improved.
Rated voltage, kV
Maximum operating voltage, kV
Rated current, A
Rated breaking current, kA
Nominal relative content of aperiodic component, %, no more
Short-circuit through current parameters, kA
highest peak
Initial effective value of the periodic component
thermal current
Thermal current flow time, s
Turn-on current parameters, kA
highest peak
Initial effective value of the periodic component
Current of unloaded lines, disconnected without repeated breakdowns, A, not more than
Current of a single capacitor bank, disconnected without repeated breakdowns, A
Solidly grounded or insulated neutral
With solidly grounded neutral
Shunt reactor inductive current, A
Own shutdown time, s
Total shutdown time, s
Minimum dead time during AR, s
Own turn-on time, s
Time difference of poles operation, s, no more
When turned on
When disconnected
Gas consumption for leaks per year, % of gas mass, no more
Quantity Required : 1 Unit/Units
Shipping Terms : CIF
Destination Port : Kazakhstan
Payment Terms : LC
Looking for suppliers from : Worldwide
Contact : Zhan Suleiman