Please quote for the following wholesale product requirement -
Product Name: Nuts, Bolts
Specifications:
Type: Nuts, Bolts, Screws, Etc.
Material: Steel, Metal, Aluminum, Etc.
Size: Customize
Packaging Terms : Standard
Quantity Required : MOQ
Shipping Terms : Ex Works
Destination Port : Amman/ Aqaba, Jordan
Payment Terms : To be discussed with suppliers
Looking for suppliers from : Worldwide
Contact : Susan
Fasteners like washers, bolts and nuts
Automotive parts: engine mounts, transmission mounts, rubber parts, bushings, autmotive bolts and nuts, suspension parts, brake parts, primarily for japanese vehicles
Bolts And Nuts
Stud Bolts
Fastener, Stationery, Dewatering, Auto Parts, Bicycle & Spare Parts, Electrical Products, Construction Materials, Hand Tools, Medical Equipment, Safety Equipment, Solar System & Fitting, Inverter Batteries, Tiles, Tyre & Tubes, A4 Copy Paper, Packing Material, Plywood, Wood Laminate, Wooden Doors, Flush Doors
Diesel fuel en590, gasoline 91/95 octane, crude oil, white kerosene oil, carbon steel pipes, stainless steel pipes, stainless steel fittings, carbon steel fittings, forged carbon steel fittings, forged stainless steel fittings, malleable iron fittings, galvanized malleable fittings, forged carbon steel flanges, forged stainless steel flanges, forged carbon steel valves, forged stainless valves, for electrical fittings rigid & pvc coated, for welding solutions, for industrial safety equipments, power tools, tools, consumables, valves, pipe tools tech, p.p.e, hoses, fasteners & fitting, gaskets, pipes, filters, hand tools, pvf, ups, control panel, pumps & motors , bearing & other industrial material.
Please provide a quotation to the following requirement from importer -
Product Name: Voltage Regulator
Specifications:
Details :
1. set Of 10mva(200a) Open Delta Voltage Regulator Unit , 33 Kv With
± 10% Regulation, Complete With
Control Panel And All Accessories As Mentioned In Our Requirements set 1
Technical Specifications
1. scope
This Standard Specifies The Requirements For Automatic Voltage Regulators For Use On Ohl 33kv Electricity Distribution Network.
2. system Parameters
(a) nominal Voltage - 33kv
(b) system Highest Voltage - 36kv
(c) system Frequency - 50hz
(d) number Of Phases - 3
(e) method Of Earthing - Resistance
(f) system Fault Current - 25 Ka
3. service Conditions
(a) annual Average Ambient Temperature: 30oc
(b) maximum Ambient Temperature: 50oc
(c) maximum Relative Humidity: 90%
(d) environmental Conditions: Tropical Climate.
(e) operational Altitude: From 400 M Under Msl To 1400m Above Msl
4. standard Regulator Operating Condition
(a) the Temperature Rise Of Top Oil At Cmr Above Specified Design Ambient Shall Be 50oc.
(b) the Temperature Rise Of Windings At Cmr Above Specified Design Ambient Temp Shall Be 55oc.
5. application Standard
This Standard Makes Reference To The Following Documents Or Any Equivalent International Standards:
• ieee Std C57.15 Standard Requirements, Terminology, And Test Code For
• step-voltage Regulators.
• iec 60296 Insulating Oil For Transformers And Switchgears.
• iec 60076 Power Transformers.
• bsi Bs 381c Specification For Colors For Identification, Coding, And Special Purposes.
• bsi Bs En Iso 1461- Hot Dip Galvanized Coatings On Iron And Steel Articles.
• bs 2562 Specifications For Cable Boxes For Transformers And Reactors.
• bs 3692 Iso Metric Precision Hexagonal Bolts, Screws& Nuts.
• bs 4190 Iso Metric Black Hexagonal Bolts, Screws And Nuts.
• bsi Bs 7079 Surface Finish Of Blast Cleaned Steel For Painting.
• iec 60529 Specification For Degree Of Protection Provided By Enclosures.
• bs 5493 Code Of Practice For Protective Coating Of Iron And Steel Structures Against Corrosion.
• iec 60076-10 Method Of Measurement Of Transformer And Reactor Sound Levels.
• iec 60076-7 Loading Guide For Oil Immersed Power Transformers.
As Per Moq
Quantity Required : MOQ
Shipping Terms : CIF
Destination Port : Aqaba, Jordan
Payment Terms : LC/TT
Looking for suppliers from : Worldwide
Contact : Ramzi Saba
Please quote for the following wholesale product requirement -
Product Name: Repair Clamps
Specifications:
Bands
Nominal Pipe Size (Inch)
Pipes Material Type
Length (mm)
No. bolts
Single Band 2
HDPE
3500
150 2
3
DI
150
150
2
4
DI
1000
150
2
5
HDPE
1000
150
2
6
DI
200
200
3
Double Bands
8
DI
25
300
3*
1. SCOPE
This Specification specifies the requirements for the design, materials and in-service performance of mechanical stainless steel repair clamps for waterworks purposes.
This Specification is designated for applications involving rigid pipes, typically ductile iron (DI), grey cast iron (CI), and steel (S). Also, for applications involving flexible pipes, typically un-plasticized polyvinylchloride (PVC-U) and high-density polyethylene (HDPE).
All materials and Equipment shall be in every respect suitable for storage, installation, use and operation in the conditions of temperature, humidity and The PH and water quality appertaining in Jordan.
The atmospheric temperature in Jordan varies between -10 C and 50 C.
2. Application
Stainless steel repair clamps complying with this specification are intended for use in repair of water supply pipelines of the size designated in Table 1, with a maximum service temperature of 50°C and up to an allowable operating pressure of 16 bars for ranges diameter up to 250 mm and 10 bar for diameters larger than 250 mm. Repair clamps have limited ability to accommodate axial deflection and are, therefore, not generally intended for use as couplings to join tow pipes together. However, they are commonly utilized for repair situations at full pipe break, where the pipe ends are considered stable. In addition, repair clamps complying with this specification are intended to provide a permanent means of preventing loss from or contamination of pipelines that have been affected by corrosion or mechanical damage in both above-ground and buried applications.
3. Materials
The material of the Clamps shall be
Bands: Stainless Steel Grade AISI 304(A2) to BS1449:1991: part 2 or Grade AISI 316(A4) stainless steel to BS 1449:1991:part 2, for corrosion resistance.
Bolts shall be Stainless Steel A2, Teflon coated, or mild steel. Nuts & washers shall be Stainless Steel A2, or mild steel class 4.6 to BS EN20898: Part 1. Receiver bars shall be TIG- welded to shell to form strong fusion, and fully passivated after welding,
Gasket shall have a gridded pattern for positive sealing, and to be made of specially compounded NBR rubber specially formulated for water service or EPDM. Compound Grade E to BS2494:1990
4. Design
The Clamps shall be used for permanent repair of cracks, holes, or complete breakages of steel, ductile Iron, PVC and HDPE pipes.
The Clamps shall be suitable for potable water for Temperature range (-10 to 50) C. potable water certificate must be submitted .
Repair Clamps shall be standard full circle single band for diameter 150mm or less. And full circle double band for diameter more than 150mm, length and number of bolts not less than the values in Table 1 for each diameter.
Gasket shall provide a 360o sealing surface and of such size and shape to provide an adequate compressive force against the pipe after assembling to affect a positive seal under all combinations of joint and gasket tolerances. And heavy gauge Type 304 stainless Steel bridge plate shall be attached into the gasket end to span the lug area and to make installation quick and easy.
Bolt retainer assembly or lugs shall be of a type 304 stainless steel, and shall be MIG welded to receiver bar and fully passivated after welding. Lugs may be cast, forged or cold formed of type 304 stainless steel, and may include a high impact polycarbonate plastic, non corrosive retainer. Lug design shall
Quantity Required : MOQ
Shipping Terms : CFR
Destination Port : Aqaba, Jordan
Payment Terms : LC
Looking for suppliers from : Worldwide
Con
The buyer would like to receive quotations for -
Product Name: Pond Water Circulation Pumps And Vacuum Pumps
Specifications :
Pond Water Circulation Pumps And Vacuum Pumps
The Basins Are Constructed According To Code 937 And Operate On Site Electricity General (circulation And Drain Pumps) Ip 54 And Price Includes The Following
All Necessary Parts For Connecting The Pump To The Water Network Separation Valves And Valves Before And After The Pump And The Necessary Flanges And The Returns After The Pump And Inside The Water Intake Source And Filters And Flexible Connections, Pipes And Other Parts Necessary For Operations Installation.
Dry Run Low Level And Control Pressure Switches
Electric Supply To The Pump And From The Nearest Electrical Source Only What Is On The Electrical Diagrams.
Appropriate Concrete Bases And Appropriate Vibration Isolation Bases Inertia Base
Operation And Control Panel For Piston Pumps Operation, Extinguishing, Contactors, Overloads, And Signal Bulbs With All The Necessary Electrical Extensions Such As Wires, Pipes And Cans For Connection From The Operation Panel To The Pumps :
Pump Capacity 5.4l/sec, 70m Pressure (cp-l1-01) (three Working And One Spare) Number =4
Pumps With A Capacity Of 4.15 Liters Per Second, 46 Meters Of Pressure (cwp-l1-01) (two Working And One Spare) Number= 3.
And Another Type Of Pump If It Available For You Please Provide Us With Price
Submersible Pump For Pumping Water From Manholes (sewage Pump)
Construction Of Stator And Housing: Heavy Duty Cast Iron With Epoxy Paint.
Shaft: Stainless Steel.
Screws And Bolts: Steel.
50 Hz. – Single Phase.
Horizontal Outlet.
Operation Temperature From Oc – 40c.
Electrical Float Switch.
Electrical Power Cable (5)m Length One Piece Water
Proof. And High Quality Insulation.
Heavy Duty Ball Bearing And Permanently Lubricated
For Long Operating Life.
Brass Or Cast Iron Isolating Valve.
Suitable Hook Or Eye Bolt As Specified From The
Manufacture With Stainless Steel Lifting Cable, With A
Shackle.
Elbows And Flanges Shall Be Form Cast Iron.
All The Caskets Needed As Specified From The
Manufacture.
Easily-removed And Serviced Motor.
Oil Filled Or Air Filled Motors
Supplied With Thermal Protection.
Low Velocity (rpm) Is Preferable.
Hdpe Piping To Nearest Sub Lake As Per Drawing
2.0L/sec pump capacity, 12m pressure (SMP-1) number = 2
Quantity Required : MOQ
Shipping Terms : CIF
Destination Port : Aqaba, Jordan
Payment Terms : LC
Looking for suppliers from : South Korea (Republi, Philippines
Contact : Eng. Aya