Medical x ray films
X-ray and equipment
Diagnostic x-ray machines, computed radiography systems, Q&A instruments
X-ray tube, detector
X rays equipment
X-ray equipment
Medical x-ray machine parts and accessories
Philips mire scanning, x-ray, endoscopes
Please provide a quotation to the following requirement from importer -
Product Name : X ray Machine Cargo and Container Vehicle X Ray Inspection System-Gantry
Specifications:
Quantity Required : 20 Piece/Pieces
Quantity Required : 20 Piece/Pieces
Shipping Terms : CIF
Destination Port : United Arab Emirates
Payment Terms : LC
Looking for suppliers from : Worldwide
Contact : Yaseen Khalid
The buyer is interested to receive quotations for the following RFQ -
Product Name: X-Ray Film Viewer
Specifications:
- X-ray Film Illuminator (Viewer) . 2 Fields. Wall-Mount Diffuse, uniform, flicker-free illumination Transparent Spring-loaded film Retainers shall grip lightly and firmly without obscuring top edge details Screen shall be recessed into the cabinet to help keep the interior dust free and eliminate side light spill The film retainers shall always operate effectively maintaining an even pressure across the full width of the illuminator. Direct Starting, Luminous Source: Daylight Command and Control on Front Side. Bipolar Switch with Pilot lamp Wall Fixations shall be provided for. Cord, Local Plug Power Supply: 220V/50Hz CE; EC Marked US FDA; ISO certification"
Quantity: 8 Unit
X-Ray Unit Universal
Universal, Remote controlled Universal Unit
Processor controlled, Mixed Cassette’s Radiography and Digital Fluoroscopy screening System.
Overhead Tube on the freely moving Tube Arm without floor mounted column.
The System to be suitable for Standard Skeletal and Radiographic Examinations,
Including Lateral Exposures and Oblique Beam Projections
Fully Automatic Under Table Spot Film Device for Cassette Radiography with
Extensive Range of Cassettes, Grids, and Attachments for Image Intensifier.
Free Cassette Exposures on Table, Floor, Wheelchair, or Gurney.
Table.
Tilt: Motor Driven, +90º to -15º, automatic stop in the horizontal position
Height: approximately 85 cm.
Tabletop Outside Dimensions: length approximately 200cm,Width approximately 80cm
Radiolucent: not less than 190cm x 55cm.
Longitudinal Travel: Motor Driven, at least 160 cm
Transverse Travel: at least 20 cm
Patient Weight: at least 200 kg.
Tube Assembly.
Max. exposure voltage: 150 kV
Anode heat dissipation rate at least 30 kW for small focus and 60 kW for large focus
Anode heat storage capacity at least 500 kHU
Dual focus 0.6 mm and 1 mm
Complete filtration W 2.5 mm Al
Focus-Film Distance (SID) Fixed Variable : 115cm / 150cm. 115cm and 150cm
must be set by Motor Driven with Adjustment Speed
Oblique Projections: max.-40º-+40º ( SID 115cm.) and -35º-+35º (SID 150cm),
Automatic Parallax Compensation Between Cassette and Image Intensifier Input Screen in Central Ray.
Tube Assembly Swivel: Manually in the Range +90º to -90º with Stops max. every
10º and -90º to 180º with stops max. every 30º.
Spot Film Device.
Front loading, automatically drawing in and out, centering and format sensing for
Cassettes, of the Formats 18x24cm (8"x10") to 35 x 43cm (14"x17"), Standardized
According to IEC, ANSI and DIN
Automatic Format Collimation: must be Selected Separately According to Format
Height/Width for Cassette Spot filming; Automatic Formatting for Bucky Exposures, Object-related Collimation.
Film Segmentation: Minimum 4 on 1., in Multiple Segmentation According to Cassettes Program
Inward Movement Time: Park to Exposure position not more than 1sec.
Time Interval: Fluoroscopy/Radiography 1.0 sec. without grid movement.
Scattered Radiation Grid: Stationary 17:1, 70 Lines/cm, Fo=125cm.,
Excursion: minimum 105cm, Remote-controlled.
Compression Device.
Radio transparent, Remotely Controlled, Detachable and Replaceable Cone minimum 3 Shapes.
Compression Force range: from 5 to 155N, Movement Blockage starting from 50N
Force Indication: Digital at the System Remote Control Console.
Projection Angle: -30º-+30º.
Image Intensifier and TV System
3 Image Fields 13 to 23 cm
Visual resolution: Mean Value 5.2; 5.8; 6.4 Lp/mm
Television System Standard: Line Frequency 50Hz; 625 Lines with 50Hz.
TV Technology: CCD sensor, noise suppression, LIH function
Automatic Dose Stabilization (ADR)
Monitor: 44cm or more, Frame Rate at least 50 Hz.
X-Ray Generator
High Frequency, Multipulse
Up to 150 kV, ³50kW.
Automatic System: 1-Point Technique with Continuously Falling Load; 2 -,3- Point
Technique with Constant Load; 3-Point Technique with
Quantity Required : 8 Unit/Units
Shipping T
Buyer is interested to receive quotations for the following RFQ -
Product Name: XRay Accessories
Specifications :
Type: Guide Tube, Barricade Tape, Hangers, Guide Tube, Etc.
Size: Customize, Hangers 10 X 40Cm
Use: Pharma
Packaging Terms : Standard
Quantity Required : MOQ
Shipping Terms : CIF
Destination Port : Singapore
Payment Terms : Bank Transfer
Looking for suppliers from : Worldwide
Contact : Baeya
The buyer is interested to receive quotations for the following RFQ -
Product Name: X-Ray Radiation Disposable Cap Lead-free
Specifications:
Type: X-Ray Radiation Disposable Cap.125mm Lead-Free
Quantity Required : 500 Piece/Pieces(sample)
Shipping Terms : FOB
Destination Port : Italy
Payment Terms : L/C Or T/T
Looking for suppliers from : Worldwide
Contact : Alessio Pittari
The buyer would like to receive quotations for -
Product Name Name: Pure X-Ray Radiation Shielding 10mm Lead Plate
Quantity Required : MOQ
Shipping Terms : CIF
Destination Port : Singapore
Payment Terms : Bank Transfer
Looking for suppliers from : Worldwide
Contact : Hisham Dris
Please quote for the following wholesale product requirement -
Product Name: X-ray Scanner
Specifications:
- For Digitize Special Type Of Negative Films 24*24cm
Quantity Required : 1 Unit/Units
Shipping Terms : CIF
Destination Port : Saudi Arabia
Payment Terms : L/C
Looking for suppliers from : Worldwide
Contact : Ali Alshaer
Please quote for the following wholesale product requirement -
Product Name: X-Ray Tube E7252X Cannon
Specifications:
- Cannon, for medical use, X-ray E7252X
- Tube with rotating anode cannon E7252X
Quantity Required : 1 Unit/Units(sample)
Shipping Terms : CIF
Destination Port : Kyrgyzstan
Payment Terms : L/C
Looking for suppliers from : Worldwide
Contact : Daniiar Sharshenaliev
Please provide a quotation to the following requirement from importer -
Product Name: Used X-Ray machines
Specifications:
Require Scrap X-Ray machines of following Specification;
1) Allengers C-ARM HF 49 / HF49R / HF 49R+ / HF 49 image plus / HF 59
2) Siemens C-ARM Multimobil-5C / Multimobil-5E / Multimobil-5D / Multimobil 2.5
Quantity Required : 5 Unit/Units
Shipping Terms : CIF
Destination Port : India
Payment Terms : LC
Looking for suppliers from : China, United States, Viet Nam, United Arab Emirat
Contact : Swati Thorat
The buyer would like to receive quotations for -
Prooduct Name: X-Ray Machine
Specifications:
New condition
Send us the catalogue and prices
Quantity Required : 1 Twenty-Foot Container
Shipping Terms : CIF
Destination Port : Singapore, Singapore
Payment Terms : To be discussed with suppliers
Looking for suppliers from : Worldwide
Contact : Robert Kee
Please provide a quotation to the following requirement from importer -
Product Name: OEM Parts
Specifications :
For X-Ray Machine
Couplers, RF Windows, Accelerating Waveguides, Reduced Beam Focal Spot. NDT X-ray Systems. Compact 12 MeV Cyclotron.
Send Us The Catalogue And Prices
Quantity Required : 1 Twenty-Foot Container
Shipping Terms : CIF
Destination Port : Singapore
Payment Terms : To be discussed with suppliers
Looking for suppliers from : Worldwide
Contact : Robert Kee
The buyer would like to receive quotations for -
Product Name: X-Ray Film Printers
Quantity Required : 1 Unit/Units(sample)
Shipping Terms : CIF
Destination Port : Abu Dhabi, United Arab Emirates
Payment Terms : To be discussed with suppliers
Looking for suppliers from : United Arab Emirates
Contact : Abdul
The buyer would like to receive quotations for -
Product Name: Medical Imaging Digital Radiography Xray Machine
Specifications:
Mobile X-ray Machine
Quantity Required : 1 Unit/Units
Shipping Terms : CIF
Destination Port : Philippines, Philippines
Payment Terms : TT
Looking for suppliers from : Worldwide
Contact : Romeo Briton