Place of Origin: Beijing, China (Mainland) Brand Name: HYLITON POWER Model Number: LXZ250250180060 Usage: Current Phase: Single Coil Structure: Toroidal Coil Number: Autotransformer Rated frequency: 50Hz or 60Hz Rated secondary current: 5A or 1A Rated short-time thermal current: 40kA,1s Rated continuous thermal current: 120%In Continuous power-frequency voltage: 3kV , 1min Instrument security factor: FSâ?¤10 Application condition Ambient temperature -25-+40 Average temperature of day â?¤40 Altitude â?¤3000m Pollution class III Technical data Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA,1s Rated continuous thermal current 120%In Continuous power-frequency voltage 3kV , 1min Instrument security factor FSâ?¤10
Technical parameters Standards IEC60044-1; IEC 61869-2; NTC 2205; ANSI C57.13; GB1208-2006 Rated primary current 20-600A Rated load 10VA Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 120%I1n Secondary winding power-frequency voltage 3kV, 1min Instrument security factor FS10 Mechanical parameters Dimensions (WDH) (mm) 18 130 55 Weight (kg) 2.3 Operating conditions Operating temperature -35C to +55C Daily average temp
Technical parameters Standards IEC60044-1; IEC 61869-2; NTC 2205; ANSI C57.13; GB1208-2006 Rated primary current 500-1500A Rated load 20VA Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 120%I1n Secondary winding power-frequency voltage 3kV, 1min Instrument security factor FS10 Mechanical parameters Dimensions (WDH) (mm) 120x185x100 Weight (kg) 7 Operating conditions Operating temperature -35C to +55C Daily average temp
D363 & D364 range of current transformers are combination designed 3 CT in 1, save more space comparing general unit CT, suitable for primarycurrent 75A to 600A, supporting the use of molded case circuit breaker according to the rated current size.
Three phase current transformers Model: DASN240, DASN242, DASN248, DASN249, DASN250 Input current: 60-1600A Output: 5A /1 A Accuracy: 0.2/0.5/1.0
Epoxy Potting,Double-screw fastening,safe,easy to install,portable. Wide inner window,allowing clamping of big cables or bus-bars. Wide range of sizes to accommodate all the existing installations. Conforms to IEC185,BS7626,BSEN60044-1 and IEC60044-1.
DASN series three phase current transformer development of DAS series,use it in primary current 60A-1600A electric circuit , Supporting the use of plastic shell breaker.
Epoxy Potting,Double-screw fastening,safe,easy to install,portable. Wide inner window,allowing clamping of big cables or bus-bars. Wide range of sizes to accommodate all the existing installations. Conforms to IEC185,BS7626,BSEN60044-1 and IEC60044-1.
Current transformer.
We are one of the leading manufacturer of all types cts of any ratio. We manufacture both outdoor and indoor types. We manufacture both resin cast & oil cooled cts As per mutual discussion
We have emerged as the foremost trader and supplier of a comprehensive assortment of potential transformers. These transformers are extensively used for billing industrial clients or utility companies. Our high grade transformers are procured from the trusted vendors of the industry as per the set global norms. Manufactured using optimum quality raw material and latest technology at vendors’ end, the offered range is highly durable in nature. Optimum performance, durability and corrosion resistance are some of the salient features of our offered transformers that are highly valued by clients. Specifications: Potential transformers up to 400kv class As per mutual discussion
• Rated current: 5 or 50A • High accuracy • Customized specifications are accepted. Carton.
These accessories are used by switchgear industry for manufacture of switchgear panel for industries and residential.
GANZ current transformers meet the highest international quality standards with more than 50 years of experience in industry.
Using excellent material,good precious current and high efficiency. Application: Used for electricity equipment for inspection control
Product description Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard technical parameter Temperature -5 40 Relative humidity 80% Rated Primary Current 5-5000A 5A,1A Rated secondary current 5A 1A Accuracy Class 0.05S Allow long-term work under the rated current; More than120A across the core. Precautions The current of standard CT and tested CT must be the same in CT calibration. Follow the given wiring diagram strictly. Test whether the load box is accurate or not before calibrating the transformer. Forbid secondary winding opening during the calibration. Select demagnetization before calibration.The wiring diagram is shown in figure 5. Short out the secondary winding before cutting off the power when the demagnetization is finished. Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Product description Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard technical parameter 1. Temperature: 2. Relative humidity 3. Rated Primary Current:5-5000A 5A,1A 4.Rated secondary current:5 1A 5 Accuracy Class 0.05S 6. Allow long-term work under the rated current; More than120A across the core. Precautions: 1. The current of standard CT and tested CT must be the same in CT calibration. 2. Follow the given wiring diagram strictly. 3. Test whether the load box is accurate or not before calibrating the transformer. 4. Forbid secondary winding opening during the calibration. 5. Select demagnetization before calibration.The wiring diagram is shown in figure 5. Short out the secondary winding before cutting off the power when the demagnetization is finished. 6.Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Specifications Condition New Frequency 0-50Hz, 100-200Hz, 200-400Hz Tensile Strength 125-150Mpa, 175-200Mpa, 75-100Mpa Features Easy To Install, Four Times Stronger, Superior Finish Warrenty 5yrs Automation Grade Automatic Production Power 100-250kw, 250-500kw, 50-100kw, 500-750kw
Characteristic 1.oil immersed test transformer has excellent material selection, reliable quality and good stability 2.the voltage margin, corona sound small, small board 3.the use of new insulation materials, small size, light weight test Packaging Details: 1.Wrapped with plastic film. 2.Fixed in a wooden case. 3.Wooden case on a pallet.
Rated Input Current:5A Rated Output Current:2.5mA Turns ratio:2000:1 Phase Angle Error:less than 20'(1A,100) Linear Range:0~20A(100) Mounting(mm):D5.0 * Small size * High accuracy * Good consistency * Used for current and power measurement