X Ray Doors X-ray doors are a common feature in X-ray rooms, as they provide an effective barrier against harmful radiation. The lead lining in these doors is designed to absorb and block the radiation, protecting those outside the X-ray room from exposure. When it comes to choosing lead lined doors for an X-ray room, there are a few key factors to consider. These include: Level of radiation protection required: Depending on the type of X-ray equipment being used and the frequency of use, different levels of radiation protection may be required. Make sure to consult with a radiation safety expert to determine the appropriate level of lead lining for your doors. Door size and configuration: Lead lined doors can be customized to fit a wide range of sizes and configurations, from single doors to double doors and sliding doors. Consider the layout of your X-ray room and the traffic flow when selecting the right door configuration. Material and finish: Lead lined doors can be made from a variety of materials, including wood, steel, and aluminum. Choose a material and finish that meets your aesthetic and durability requirements.
The door to an X-ray room typically needs to have certain features to ensure that it provides adequate protection for those outside the room from radiation exposure. Here are some common features of X-ray room doors: Lead-lined: X-ray room doors are often lined with lead to provide a barrier against radiation. Lead is a dense material that effectively absorbs X-rays and gamma rays. Interlocking mechanism: To prevent the door from accidentally being opened while X-rays are being produced, X-ray room doors often have an interlocking mechanism that prevents the door from being opened unless the X-ray machine is turned off. Warning signs: The door should be clearly labeled with warning signs indicating that it is an X-ray room and that radiation is being used. Door frame shielding: The door frame should also be shielded to prevent radiation from leaking out around the edges of the door. Automatic door closer: To ensure that the door is always closed when not in use, X-ray room doors often have an automatic door closer that will close the door after someone has opened it. Applications for X Ray Room Door Radiation protection is critical for the safety of workers, patients, and clients in settings where X-rays and other imaging equipment are utilized. Lead Lined wood doors defend against radiation in: Medical X-Ray, PET, or CT Scan Rooms Imaging centers Veterinary offices Airports Defense applications Aerospace applications
Lead Lined Doors For X Ray Rooms Lead lined doors are a common feature in X-ray rooms, as they provide an effective barrier against harmful radiation. The lead lining in these doors is designed to absorb and block the radiation, protecting those outside the X-ray room from exposure. When it comes to choosing lead lined doors for an X-ray room, there are a few key factors to consider. These include: Level of radiation protection required: Depending on the type of X-ray equipment being used and the frequency of use, different levels of radiation protection may be required. Make sure to consult with a radiation safety expert to determine the appropriate level of lead lining for your doors. Door size and configuration: Lead lined doors can be customized to fit a wide range of sizes and configurations, from single doors to double doors and sliding doors. Consider the layout of your X-ray room and the traffic flow when selecting the right door configuration. Material and finish: Lead lined doors can be made from a variety of materials, including wood, steel, and aluminum. Choose a material and finish that meets your aesthetic and durability requirements. Advantage Lead lined doors are essential for X-ray rooms because they provide a significant advantage in terms of radiation protection. Here are some of the advantages of lead lined doors for X-ray rooms: Radiation Shielding: The primary purpose of lead lined doors is to shield against ionizing radiation, which is harmful to humans. Lead is a dense metal that effectively absorbs radiation and prevents it from escaping the room. This feature is particularly important in X-ray rooms where high levels of radiation are produced. Safety: Lead lined doors are designed to provide a safe working environment for staff and patients in X-ray rooms. The lead lining in the doors prevents radiation from escaping the room, which can be harmful to people working nearby. By using lead lined doors, you can ensure that the radiation stays within the X-ray room, reducing the risk of exposure to others. Regulatory Compliance: The use of lead lined doors is a regulatory requirement in many countries to ensure that X-ray rooms meet the required safety standards. By installing lead lined doors, you can ensure that your X-ray room complies with local regulations and standards. Durability: Lead lined doors are designed to last for many years with minimal maintenance. They are made with high-quality materials that are resistant to wear and tear, ensuring that they provide reliable radiation shielding for an extended period. Cost-Effective: While lead lined doors may be more expensive than regular doors, they are a cost-effective investment in the long run. By providing effective radiation shielding, lead lined doors can help you avoid costly fines, lawsuits, and damage to equipment and facilities.
DESCRIPTIOn: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT: 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY : Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND counter Balance Mobile
DESCRIPTION: Titanx RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Floor to Ceiling Column Stand
DESCRIPTION: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Counter Balance Mobile
DESCRIPTION- TITANX 100 RADIOGRAPHY RATING- 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT 8KW RECTIFICATION- Full Wave Rectified TIMER- 0.06 to 5 sec DIGITAL DISPLAY- Digital Display of mAs, kV & mA X-RAY TUBE- XD-3/Imported POWER SUPPLY- 230 Voltage AC, 15 Amps LINE REGULATION- 10% 0.6max PROTECTION- Electronic overload Protection TUBE STAND- Spring Balance
X ray machines, Mammography machines, digital Xray, OPG machines, C Arm, dental Xray, Portable X ray.Manufacturing and export
X ray baggage scanner, boom barrier, walk through metal detectors, rolling shutter motor, flap barrier, tripod turnstile, swing gate motor, sliding gate motor.Manufacture
1. When adding up voltage, total current is less than 2a and total power is 500w; 2. The current and voltage of x-ray tubes are fixed in three groups, they are: X exposure voltag (kvp) 60 65 70 X-ray current (ma) 0.5 0.85 1.10 3. When adding up voltage, total current is less than 2a and total power is 500w 4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1 5. The three groups of voltage (60kv, 65kv, 70kv) are adjustable. 6. Wireless remote control in any angles within 10 meters part form the control box 7. The parameter of x-ray generator (bulb tube head) the parameter of x-ray tubes A focus index: 0.3*0.3mm2 B. The voltage of the-highest-voltage generator: 90kv C. The highest inverse peak voltage: 90kv D. Filament characteristic: vf=5v+0.5v, f=3a E. Target surface obliquity: 12 F. The cooling manner of bulb tube head: oil immersion The parameter of x-ray generator (bulb tube head): A. Focus-skin distance: 200mm B.The thickness of filter-ray film: more than 1.5mmal C.The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h) D. The manner of limiting beam: using planigraphic device
Detecting such as stone ,sand,teflon,fe,sus ,non-fe,harder material and so on in the food stuff
PLX101 Series High Frequency Mobile X-ray Equipment PLX101/101A/101C Rocker safety lock design, make your operate much safer High quality x-ray monoblock assures more details, less dose Symmetrical adjustable collimator for accurate positioning and better exposure protection Aviation aluminum connectors, connection reliable, more safety Advanced dislocation braking system, flexible movement, flexible braking Multifunctional cassette storage box design Features Our high frequency technology assures the best image in every operating condition Along with reduced patient dose and extended x-ray tube life time The generator provide the right amount of penetration, reducing exposure times and retakes. The parameter can be adjusted by the kV and mAs. Multiple security protect function such as over-voltage, over-current. 50 preset exposure programs allow extensive possibilities to optimize the exposure and processing parameters according to your preferences. Fault automatic protection setting and fault alarming display Parameters are automatically storage when power cut off. Adopt rotating beam limiting device to adjust the X-ray field and angle freely. Adopt manual controller and remote controller to do exposure. Optional: PLXF152 mobile table for high frequency mobile X-ray equipment. PLX101D is equipped with built-in battery, can take 200 films when full charged. Rocker can move up and down, automatically balance High quality X-ray monoblock can rotate in ±90 Options PLXF152 Mobile Bed For Mobile X-ray Machine Size: 2000 X 700X 500mm Range of grid box movement 1210mm Size of grid box: 430X 430(17 X 17) Bucky Stand Height: 1770mm Vertical movement range: 470-1470mm Grid density: 103L/inch Grid radio: 10:1 Focus distance: 150cm Maximum grid box: 17 X 17 Technical Parameters