Timing Kit available for Hyundai and Kia
DESCRIPTION * Detection of Sars-Cov-2 with reverse transcption Real time PCR ( TAT 2.0 hr ) * Amplify N gene and RdRp(orf1ab) gene of Sars-Cov2 AVAILABLE SAMPLE TYPE * Sputum * Oropharyngeal ( OP ) and nasopharyngeal ( NP ) swabs
2X Real-Time PCR Master Mix including SYBR Green in Mixture 2X HRM Master mix
This product qualitatively confirms the presence or absence of a new coronavirus (2019-nCoV, COVID-19) using reverse-transcription Real Time Polymerase Chain Reaction in sputum, oropharyngeal and nasopharyngeal specimens. It is an in vitro diagnostic medical device.
STANDARD M nCoV Real-Time Detection kit is used for rapid identification and detection of novel coronavirus (2019-nCoV) nucleic acids in human nasopharyngeal swabs and throat swab samples. Coronavirus RNA was first transcribed into cDNA by reverse transcriptase, and then cDNA was used as a template for PCR amplification. The separation of the fluorophore and quencher makes the fluorescence signal detected by the instrument: FAM channel qualitative detection of the new coronavirus (COVID-19) ORF1ab gene, and JOE channel qualitative detection of coronavirus) E gene, and CY5 channel detection internal reference. The kit uses dUTP and UNG enzymes to prevent contamination of amplification products.
Unit Price: USD 15 Target Region: RdRP, E gene, N gene Accuracy: 100% Recommended PCR: CFX96 Real Time PCR System (Bio Rad) DTprime DT-96 QIAGEN Rotor-Gene Q Box Size: Size: W 80 x D 80 x H 65 (mm) Weight: 45g / box Certification: Korea GMP (ISO 13485 2003) European CE
Shelf life LOD Specification 200 copies/mL 48 tests/kit, 50 tests/kit ,96 tests/kit, 100 tests/kit Product name Monkeypox Virus DNA Real Time Diagnostic Kit Specimen Whole blood , skin lesion material Fluorescence channel FAM: Monkeypox conservative region, VIC: endogenous internal control Store at 2-30â??, protect from light. The validity period is 12 months ABI 7500 Real-Time Fluorescent Quantitative PCR ,LightCycler 480 Gentier 96 Real-Time PCR System,QPT1000 Real-time PCR system
Test Covid19 with CE
Biocore 2019-nCoV Real Time PCR Kit - Brand: BIOCORE - Detailed information: 1.Type: RT-PCR 2. Reading Test Result: 1 hours 3. Accuracy: 95% 4. Storage: 2-30 â?? 5. Device reading: ***CFX96 ***SLAN-96P ***Applied Biosystems 7500 RT-PCR 6. MOQ: 10.000T (200Kit) 7. Packing: 100T / Kit 8. License: CE / GMP - Price: $13.00 / 1T - Payment: L/C or T/T
SFTS Virus Real-time PCR Kit is an in vitro diagnostic test intended for the qualitative detection of the Dabie bandavirus that causes Severe Fever with thrombocytopenia Syndrome using nucleic acid RNA extracted from human blood or serum. Clinical evaluation performed with human blood specimens confirmed clinical accuracy. High reproducibility with similar results were confirmed various tests.
Ezplex Respiratory Pathogens Real-time PCR Kit is an in vitro diagnostic test for the qualitative detection of 19 respiratory viruses and 6 types of pneumonia-causing bacteria through nucleic acids isolated and extracted from human throat swabs using real-time polymerase chain reaction Comprehensive Panel- One test can identify 19 respiratory viruses and 6 bacterial species simultaneously. Sensitivity Detection of all targeted viruses and bacteria with high sensitivity. Convenience Genetree Viewer analysis software available for users to conveniently produce test results. Clinical Performance: Clinical testing confirmed the high sensitivity and specificity. Stability: Shelf life of up to 12 months. Analytical Specificity: Testing of 31 species of microorganisms showed no cross reactivity.
Monkeypox Virus Real-time PCR Kit. PM for details.
Standard Timing Belt Kit For " Audi & Volkswagen " Part Number : 06F198119A
25 tests per box
Lowest detection line:200 copy/ml CE marks
African swine fever virus (ASFV) real-time PCR test kit enables the safe detection of African swine fever virus DNA in serum, blood, tissue, lymph nodes, spleen, muscle from pigs and breeding environment samples within 40 minutes. The kit consists of fluorescence PCR mix , positive control , negative control and lysis solution for real-time PCR amplification of ASFV. Fluorescence PCR mix contains primers, probes, enzyme and buffer for detection of the ASFV P72 gene. In addition, the role of lysis solution is to simply process samples and release DNA.
COVID-19 Real Time RT-PCR Kit detects the novel corona virus, COVID-19 using one-step real-time RT-PCR in a single tube. The target genes for the detection of the virus are Orf1 ab and N gene. The kit includes primers and probe set targeting the human Rnase P gene that serves as an internal positive control for the real-time RT-PCR. Ordering Info : 96 Tests/Kit (MOQ : 10 Kits)
Product Details: Brand : TRIVITRON Signal Signifies : Orthopox group, Monkeypox & Smallpox Virus Test time : 1 hour Compatible : Please visit Brochure Storage : : - 20 between 2 C Cat No : DVZ-30052 & DVZ-30053 Trivitron's Monkeypox Real-Time PCR kit is a multiplex RT-PCR Kit for the rapid qualitative in vitro detection of Monkeypox and Smallpox virus. The assay Kit can distinguish between smallpox and Monkeypox virus. FEATURES The kit is based upon Single Step RT-PCR, where both Reverse Transcription by Reverse Transcriptase and PCR by Taq Polymerase takes place in single tube. Monkey Pox virus kit is developed using four colour fluorescence technology. A signal from different channel signifies, presence of Orthopox group, Monkeypox & Smallpox virus respectively in the sample. Assay validation through the additional human internal control gene. Compatible with both dry swabs as well as sample swabs placed in VTM. A total turnaround time of 1 hour TECHNICAL SPECIFICATIONS The kit has been validated on QuantStudio-5/3 and Bio-Rad CFX96, 384 and can also be used on applied Biosystems 7300/7500, Roche Diagnostics LightCycler 96/480, Qiagen Rotor-Gene Q, etc. (Instrument should be calibrated, maintained and used as per manufacturer recommendation). Sample type: Swab samples collected from surface and/or exudate, roofs from more than one lesion, or lesion crusts. Storage: -20 + 2 C
Helicobacter pylori is a parasitic bacterium in the stomach that lives between the gastric mucosa and mucus. According to the WHO, more than half of the world's population has H. pylori and is the third leading cause of cancer-related deaths. In 1994, the WHO's IARC classified H. Pylori as a Class 1 carcinogen. The incidence of H. pylori in developing countries is the highest worldwide, highlighting the need for highly accurate and manageable testing. By 2025, the H. pylori testing market is expected to be worth 6 billion. Accordingly, SML Genetree has developed a reagent that can diagnose Helico-bacter pylori and Clarithromycin-resistant mutants (A2142G, A2143G) through DNA extracted from human hygienic tissue using Real-time Polymerase Chain Reaction. Since it contains multiple gene regions, Helico-bacter pylori and Clarithromycin-resistant mutations can be detected sensitively, and high reproducibility has been demonstrated through repeated tests by serially diluting various positive samples and standards. In addition, as a result of clinical evaluation on human sanitary inspection tissue by commissioning a large domestic consignment inspection institution, high sensitivity and specificity were confirmed, proving its excellent clinical performance.
Ezplex MTBC/NTM Real-time PCR Kit is an in vitro diagnostic test that simultaneously detects Mycobacterium tuberculosis complex (MTBC) and 20 types of nontuberculous mycobacteria (NTM). Sensitivity : Multiple gene targets for MTBC and NTM. Clinical Performance: Validated clinical performance. Fast Results: Testing can be completed within 2 hours post extraction.