Features  � High stability optical chamber � Circular LED indicator for 360° visibility � Network by current, NONC optional � Adapts CMOS with low power consumption � High adaptability to the ambient with dustproof, mothproof,  moistureproof, anti-white light and high EMI immunity � Input voltage: 10-35V DC � Orientation differences:
SD13 Smoke Alarm Key Features: * Worry-free! 10-year sealed-in lithium battery * Advanced photoelectric sensing technology offers high sensitivity * Auto-check malfunction * Low battery warning * Manual Test & Auto-Reset * Dustproof, mothproof & Anti-visible light * Anti-RFI (20V/M-1GHz) SD13 Smoke Alarm Specifications: * Sensor Type: Photoelectric * Alarm Sound: >85dB (3meter) * Power Supply: DC 3V lithium battery (included) * Power Supply Life: 10 years * Alarm Current:
Sd13 smoke alarm key features: * worry-free! 10-year sealed-in lithium battery * advanced photoelectric sensing technology offers high sensitivity * auto-check malfunction * low battery warning * manual test & auto-reset * dustproof, mothproof & anti-visible light * anti-rfi (20v/m-1ghz) Sd13 smoke alarm specifications: * sensor type: photoelectric * alarm sound: >85db (3m) * power supply: dc 3v lithium battery (included) * power supply life: 10 years * alarm current:
Smoke & co detectorHeat detector ntc thermal sensor tamper resistant pins for battery4 digits temperature led display shockproof design, suitable for vehicle usecan set maximum or minimum alarm temperature simultaneously test and hush button, auto resetreal ambient temperature correctable on-top battery compartment, easy for battery replacementauto reset /power off reset optional Execute criterion: en54-4, ul539, en14604, ul217 dustproof, mothproof and anti-white light ElectrovalveManipulator gas species: natural gas, lpg, man-made coal gas and other noncorrosive gaspower supply: 8vdc-16vdc 12vdc-26vdc valve body material: brass alloyoperation press: 1.6mpa material for sealing: nbr rubbervalve specification: 4 fen (1fen=1/3centimeter), 6fen, 1 inch, 1.25 inch, 1.5 inch test operating pressure: 25kpa torque: 10kg.Cm~30kg.Cm~40kg.Cm~50kg.Cm11069.540mm Anti-electromagnetic interference, no-spark design Alarm bellBreak glass manual call point size: 2", 3", 4", 6", 8", 9", 10", 12"rated voltage :12vdc or 24vdc / 220vac optional volume: over 105db/mconsumption: 10w working voltage : 12vdc/24vdc With waterproof cover manual call pointSiren with strobe
Enerna IoTech WiFi Smart IoT Wireless Smoke Fire Alarm Detector Smoke Detector. Wireless smart photoelectric smoke sensor, with Ultra-low-power MCU design. It is capable of real-time detecting the Presence of smoke. Once detect danger of fire smoke, red LED will be ON, and alarming to alert you and your family timely. Enerna IoTech WiFi Smart IoT Wireless Smoke Fire Alarm Detector. the whole solution is just smoke detector alarm to app Platform directly, can be real-time monitoring remotely. this solution Can save much cost from main alarm panels, and it also can be linkage to Other smart device to work together. It will be easy to match different Project applications, such as building office, warehouse, supermarket, Factory, restaurant, hotel Enerna IoTech WiFi Smart IoT Wireless Smoke Fire Alarm Detector is a smart Photoelectric smoke sensor, with ultra-low-power MCU design. It is Capable of real-time detecting the presence of smoke. Once detect danger of fire smoke, red LED will be ON, and alarming to alert you and your family timely. It can be widely used in household, lounge, Coffee house, dancing hall, and any other places need fire alarm Monitoring. this Enerna IoTech WiFi Smart IoT Wireless Smoke Fire Alarm Detector can work Standalone. When detects smoke, alarm will sound and send push message for alert. Meanwhile, it can link with other smart products on Tuya Platform. Keep your house safe. Enerna IoTech WiFi Smart IoT Wireless Smoke Fire Alarm Detector Function: 1. APP remote control 2. Link with TUYA smart home products together 3. Maze technology and small size 4. 80dB sound alarm alert 5. Ultra low power Skype: iotech(at)foxmail.com Whatsapp: 0086-137-2827-9456 Wechat: 13728279456 Web: Enerna-IoTech.com Package: 1x Enerna IoTech WiFi Smart IoT Wireless Smoke Fire Alarm Detector 1x User Manual
SNC-300 non-addressable photoelectric smoke detectors are state-of-the-art detectors suitable for connection to 2-wire or 4-wire non-addressable fire detection control and indicating equipment, or to addressable fire detection Control and indicating equipment that can accept non-addressable type detectors. Advanced electronics in conjunction with a photoelectric smoke sensing chamber provide early detection of fire And high immunity against unwanted alarms. Photoelectric smoke sensor Analogue detection discrimination Dual leds for 360° visibility 2-wire and 4-wire models for dc 12 v and dc 24 v operation 4-wire model for dc 48 v operation 4-wire models available with a n/o alarm relay output 4-wire models available with auto-reset 2-wire models available with remote led output Connects to zone monitor for use with addressable control and indicating equipment
Snc-300 non-addressable photoelectric smoke/heat detectors are state-of-the-art detectors suitable for connection To 2-wire or 4-wire non-addressable fire detection control and indicating equipment, or to addressable fire detection Control and indicating equipment that can accept non-addressable type detectors. Advanced electronics in conjunction with a photoelectric smoke sensing chamber and an electronic thermistor Provide early detection of fire and high immunity against unwanted alarms. The heat sensor provides sensitive Rate-of-rise operation or fixed-temperature operation when the response threshold value is exceeded. Photoelectric smoke and heat sensors Analogue detection discrimination Dual leds for 360° visibility 2-wire and 4-wire models for dc 12 v and dc 24 v operation 4-wire model for dc 48 v operation 4-wire models available with a n/o alarm relay output 4-wire models available with auto-reset 2-wire models available with remote led output Connects to zone monitor for use with addressable control and indicating equipment
Model NO SR-825PHS Operating voltage 3V lithium battery Static current 8uA Alarm current 35mA Alarm output Sound & Flash alarm Sound level 85dB/3m Installation Ceiling mounted Sensitivity 1.8%ft ±0.8%ft Working environment -10~+50,(95%RH No congelation) Dimension 95*41mm
Conventional fire alarm smoke detector smoke probe sensor This device is photoeletronic detector uses a state-of-the-art optical sensing chamber. This smoke detector is compatible with all conventional fire alarm control panel Dual leds, two leds blink standby, provide 360dgree visibility With unique optical sensing chamber, engineered to sense smoke by a wide range of combustion sources. Unpolarized wire input to prevent the likelihood of wiring errors Specifications Operating voltage range: 9 to 28vdc volts non-polarized Standby current: 60µa @ 24 vdc Maximum alarm current (led on: ) 30ma @ 24 vdc Operating humidity range: 10% to 93% relative humidity, non-condensing Operating temperature range: 14°f to 122°f (-10°c to50°c) Adjustable sensitivity: 0.15ï½?0.3db/m Height: 2.2ë� (55 mm) installed in base Diameter: 4.0ë� (103 mm) Weight: 5.5 oz. (155 g)
SNA-360 analogue addressable photoelectric smoke/heat detectors are microprocessor controlled state-of-the-art Detectors compatible with popular control and indicating equipment loop protocols. Advanced electronics in conjunction with a photoelectric smoke sensing chamber and an electronic thermistor provide Early detection of fire and high immunity against unwanted alarms. The heat sensor provides sensitive rate-of-rise Operation or fixed-temperature operation when the response threshold value is exceeded. Photoelectric smoke and heat sensors Analogue detection discrimination Dual leds for 360° visibility Dc 24 v operation 2-wire connection to many popular loop protocols Dip switch address setting 125 usable detector address settings per loop Optional remote led output
Snd-500 dc smoke alarms provide battery powered smoke detection and alarm functions within a single unit. Advanced electronics in conjunction with a photoelectric smoke sensing chamber provide early detection of fire And high immunity against unwanted alarms. Snd-500 dc smoke alarms are battery powered, do not require a mains supply, and are suitable for general Residential applications. Photoelectric smoke sensor Integrated indicator provides visual indication of an alarm condition Test button verifies battery and alarm operation Loud 85 db sounder to alert occupants Single dc 9 v user-replaceable battery provides up to 18 months operation under normal conditions 30 day low battery warning signal Interconnection function available to connect up to 38 units together Battery missing indicator
The 6001 analogue addressable control and indicating equipment forms the central part of a fire detection and alarm System. The fully networkable 2-wire 6001 is compatible with numens addressable devices and can also be Connected to non-addressable devices when used with addressable input modules. Default configuration programming facilitates out-of-box installation and rapid commissioning. A powerful and versatile Cause-and-effect pc-based programming tool enables rapid customization with software for sites that require Special operating features. The 6001 comes standard with features that allows flexibility and expandability. Single loop or 2-loop options available Single loop, expandable to 2-loops available Networkable, up to 4 control panels Up to 125 addressable devices per loop Automatic device detection on start-up Automatic device type-code verification 2 independently programmable non-addressable a/v alarm output circuits 2 programmable fire alarm relay outputs Fault relay output Backlit lcd display providing 4 rows of 40 characters 16 zone fire alarm led indicators 3000 event history log
The 442 audio/visual alarm devices are suitable for connection to 2-wire and 4-wire fire detection and alarm Systems. 441 will operate with both addressable and non-addressable fire detection control and indicating equipment. Activation is initiated upon connection of the operating voltage, allowing connection to either a switched supply or Via an addressable module. Visual, audible and audio/visual models available Red or white body available for audible alarm device Operates when the supply voltage is connected to the device Compatible with relay outputs from control and indicating equipment, or from an output module connected to addressable alarm circuit wiring Dc 24 v operation Loud sounder output of 85 db at 1 m Long-life leds Zero current load in quiescent condition
The 660 manual call points includes a pressure-activated displacement element to provide a safe and convenient Way for building occupants to manually initiate a fire alarm condition. Resetting the manual call point is achieved by inserting a key through the underside of the unit to replace the Operating face to the quiescent position. Pressure activated displacement element provides a safe user experience Integral indicator to show polling and alarm activation Resettable with simple key operation Suitable for indoor use Monitors for quiescent, alarm and fault conditions Dip switch address setting 125 usable detector address settings per loop
The 6001 analogue addressable control and indicating equipment forms the central part of a fire detection and alarm System. The fully networkable 2-wire 6001 is compatible with numens addressable devices and can also be connected To non-addressable devices when used with addressable input modules. Default configuration programming facilitates out-of-box installation and rapid commissioning. A powerful and versatile Cause-and-effect pc-based programming tool enables rapid customization with software for sites that Require special operating features. The 6001 comes standard with features that allows flexibility and expandability. Single loop or 2-loop options available Single loop, expandable to 2-loops available Networkable, up to 4 control panels Up to 125 addressable devices per loop Automatic device detection on start-up Automatic device type-code verification 2 independently programmable non-addressable a/v alarm output circuits 2 programmable fire alarm relay outputs Fault relay output Backlit lcd display providing 4 rows of 40 characters 16 zone fire alarm led indicators 3000 event history log
The 640 addressable audio/visual alarm devices are suitable for connection to 2-wire addressable fire detection And alarm systems. 640 is loop-powered and activation is initiated by a dedicated initiation message from the control and indicating Equipment. Up to 125 devices can be connected to each alarm zone loop. Visual, audible and audio/visual models available Red or white body available for audible alarm device Loop-powered from control and indicating equipment Operates when a dedicated activation message is received from the control and indicating equipment Loud sounder output of 85 db at 1 m Long-life leds Low quiescent current Dip switch address setting
The 460 manual call points includes a pressure-activated displacement element to provide a safe and convenient Way for building occupants to manually initiate a fire alarm condition. Resetting the manual call point is achieved by inserting a key through the underside of the unit to replace the Operating face to the quiescent position. Pressure activated displacement element provides a safe user experience Integral indicator to show polling and alarm activation Resettable with simple key operation Suitable for indoor use Monitors for quiescent, alarm and fault conditions
The 4001 non-addressable control and indicating equipment forms the central part of a fire detection and alarm System. The 2-wire 4001 is compatible with numens non-addressable devices The 4001 comes standard with features that allows flexibility and expandability. Default configuration programming Facilitates out-of-box installation and rapid commissioning. 2, 4, 8, or 16 detection zones Up to 32 non-addressable devices per alarm zone circuit Configurable non-latching alarm zones, alarm dependency (zone coincidence detection), and output delay timer 3 access levels Single-person test mode Day/night mode Manual activation of audio/visual alarm devices Supervised auxiliary dc 24 v output 2 independently programmable non-addressable a/v alarm output circuits 2 programmable fire alarm relay outputs Fault relay output 3 voltage-free inputs for remote reset, evacuation start/stop, and day/night mode Supports up to 7 repeater panels
HNC-310 non-addressable heat detectors are suitable for connection to 2-wire non-addressable fire detection control And indicating equipment, or to addressable fire detection control and indicating equipment that can accept Non-addressable type detectors. An electronic thermistor provides sensitive rate-of-rise operation or fixed-temperature operation when the response Threshold value is exceeded. Durable heat sensor Analogue detection discrimination Dual leds for 360° visibility 2-wire and 4-wire models for dc 12 v and dc 24 v operation Dual leds for 360° visibility 4-wire models available with a n/o alarm relay output 4-wire models available with auto-reset 2-wire models available with remote led output Connects to zone monitor for use with addressable control and indicating equipment
The 640 addressable audio/visual alarm devices are suitable for connection to 2-wire addressable fire detection And alarm systems. 640 is loop-powered and activation is initiated by a dedicated initiation message from the control and indicating Equipment. Up to 125 devices can be connected to each alarm zone loop. Visual, audible and audio/visual models available Red or white body available for audible alarm device Loop-powered from control and indicating equipment Operates when a dedicated activation message is received from the control and indicating equipment Loud sounder output of 85 db at 1 m Long-life leds Low quiescent current Dip switch address setting