Performance parameters of S13 type 10kV double winding series: Type rated capacity (KVA) connection group label voltage combination (KV) no-load loss (W) load loss no-load current (%) short circuit resistance (%) High pressure range low Dy Yy. 10 10 Yyn0 / S13 - M - or Dyn11 10 6.3 6 + / - 5% Plus or minus 2 x 2.5% or + 3 x 2.5% -1 x 2.5% 0.4 40 360 340 2.8 4.0. S13-M-20, 70, 525, 500, 2.5. S13-M-30, 30, 80, 630, 600, 2.3. S13-m-5050 100 910 870 2.0. S13-m-63, 110, 1040, 1040, 1.9. S13-m-80 130 1310 1250 1.9. S13-m-100, 100, 150, 1580, 1580, 1580. S13-M-125, 125, 170, 1890, 1800, 1.7. S13-m-160, 200, 2310, 2200 1.6. S13-M-200, 240, 2730 2600 1.5. S13-m-250, 250, 290, 3,050, 1.4. S13-m-315 315340 3830 3650 1.4. S13-m-400, 4410, 452043001.3. S13-m-500, 480, 5410, 5150, 5150. S13-M-630 630 570 6200 6200 1.1. S13-m-800, 700, 7500, 7500, 1.0. S13-m-1000, 830, 10300 10300 1.0. S13-m-1250, 1250, 970, 12000, 0.9. S13-m-1600 1,170 14500 14500 0.8. S13-m-2000, 1510, 17800, 17800.0.8, 5.0. S13-M-2500, 1780 20700 20700 0.7. S13-m-3150 3150 2100 24300 24300 0.7.
Execution standard GB 1094.1-2 power transformer general rules, power transformer temperature rise GB 1094.3 power transformer insulation level and insulation test GB 1094.5 "power transformer capacity to withstand short circuit" GB/T 6451 technical parameters and requirements of three-phase oil-immersed power transformer GB/T 15164 load guide for oil-immersed power transformer IEC76 power transformer GB 2536 "transformer oil" 800KVA~31500KVA three-phase double-winding non-excitation voltage regulating power transformer:
Dry type transformers shall be installed in accordance with the manufacturer's requirements, and shall be equipped with temperature measuring devices, generally 630kVA and above transformers. A,1000kVA and above oil-immersed transformer shall be equipped with an outdoor signal thermometer and can take distant signals. Product features: A, tank using corrugated sheet, it has the respiratory function to compensate for temperature change caused by the oil volume change, so the product without oil storage tank, obviously reduce the height of the transformer. B, because the corrugated film replaces the storage tank, the transformer oil is isolated from the outside, thus effectively preventing the entry of oxygen and water and the decrease of insulation performance. C, according to the above five performance, to ensure the oil-immersed transformer within the normal operation of the don't need an oil change, greatly reduces the maintenance cost of transformer, and prolong the service life of the transformer. D. In addition to the small capacity of copper wire, copper foil is usually used in the cylinder structure. The high voltage winding adopts multi-layer cylindrical structure to balance the ampere-turns distribution of the winding, the leakage is small, the mechanical strength is high, and the anti-short circuit capability is strong. E, iron core and winding each adopt the fastening measure, the height of the device, the low voltage lead wire and other fastening parts are equipped with self-locking anti-loose nuts, adopt the non-lifting structure, can withstand the shock of transportation. F, coil and iron core adopt vacuum drying, the transformer oil adopts vacuum filter oil and oil filling process, which minimizes the moisture in the transformer.
Product features 1. The transformer core is made of imported high quality cold rolled silicon steel, which greatly reduces the no-load loss and no-load current, and the core is bound to ensure the tightness of the core and reduce the noise. 2. The high and low voltage winding is made of anaerobic copper, and the low-voltage winding 500kVA and the following are double-layered cylindrical structures. A double helix or four-helix structure is used in 630kVA and above. Multi-layer cylindrical structures are used for high voltage windings. 3. The transformer connection group adopts Dyn11 to reduce the influence of harmonics on the power grid and improve the quality of power supply. 4. The transformer is full seal structure, extending service life, free of hanging core and maintenance. 5. The measured noise is below the standard. After normal transportation, the series of transformers can be installed with relevant parts, and the test of acceptance test can be put into operation.
Dry type transformers shall be installed in accordance with the manufacturer's requirements, and shall be equipped with temperature measuring devices, generally 630kVA and above transformers. A,1000kVA and above oil-immersed transformer shall be equipped with an outdoor signal thermometer and can take distant signals. Product features: A, tank using corrugated sheet, it has the respiratory function to compensate for temperature change caused by the oil volume change, so the product without oil storage tank, obviously reduce the height of the transformer. B, because the corrugated film replaces the storage tank, the transformer oil is isolated from the outside, thus effectively preventing the entry of oxygen and water and the decrease of insulation performance. C, according to the above five performance, to ensure the oil-immersed transformer within the normal operation of the don't need an oil change, greatly reduces the maintenance cost of transformer, and prolong the service life of the transformer. D. In addition to the small capacity of copper wire, copper foil is usually used in the cylinder structure. The high voltage winding adopts multi-layer cylindrical structure to balance the ampere-turns distribution of the winding, the leakage is small, the mechanical strength is high, and the anti-short circuit capability is strong. E, iron core and winding each adopt the fastening measure, the height of the device, the low voltage lead wire and other fastening parts are equipped with self-locking anti-loose nuts, adopt the non-lifting structure, can withstand the shock of transportation. F, coil and iron core adopt vacuum drying, the transformer oil adopts vacuum filter oil and oil filling process, which minimizes the moisture in the transformer.
Our oil-immersed power transformers have stable operation, high safety and efficiency, low price and wide application. Oil-immersed power transformers are integrated with production, sales and installation, with strong strength and good reputation. Our oil-immersed power transformers have stable operation, high safety and efficiency, low price and wide application. Oil-immersed power transformers are integrated with production, sales and installation, with strong strength and good
4cst, 6cst, 8cst, etro4, etro6, naphthenic base oil, equinas 4 group 3 base oil, equinas 6 group 3 base oil, equinas 8 group 3 base oil, equinas tfo 60i high quality inhibited transformer oil, equinas tfo 60u high quality un inhibited transformer oil, drilling fluid, melamine powder, clinker, urea, chemicals, base oils and other petroleum products, industrial salt.Marine transportation and logistics marine ship and cargo survey and inspections
main parameter of 69kv CT Rated current ratio: 2000/1600/1500/1200/1100/800/500/400/300 : 5 A Rated output capacity of each corresponding ratio: 200/160/150/120/110/80/45/35/25 VA Winding accuracy class: 0.2/5P20/5P20/5P20 CNMEs business activities cover national and international engineering, Generation Stations, Electrical Engineering Equipment, all kinds of electrical equipment, Test And Design and so on. The activities consist of the industries of high voltage power transmission and distribution, diesel power generation, thermal power generation, Transformer Test Laboratory Design, Electrical Lab Design And Solution, Power Plant Design and so on.
Product description The test transformer calls the booster, it is the basic test equipment used by the power station, supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products, electrical equipments and insulated materials, testing the insulated level of products, discovering the insulated objection of quizzee, scaling the capacity burdened voltage Oil Immersed Testing Transformer 1 Technical index Model Capacity High Frequency Voltage Output Voltage High Frequency Voltage Output Current ) Low Frequency Voltage input Change Tempera- ture raised 30 minute V A 1.5 50 30 200 7.5 500 10 3 50 60 200 15 500 10 5 50 100 200 25 500 10 10 50 200 220/380 50/26 500 10
Product specifications Rated power: 2500kVA Voltage: 22/0,4kV Winding connection: Dyn11 No-load loss (Po): 1850 W Short-circuit loss(Pk): 21000 W Max. no-load current(I0): 1.5% Short circuit voltage(Uk ): 6% Standard: : TCVN 6306 (IEC 60076); Decision 62 / Q EVN (Vietnam), ISO 9001:2015; ISO 14001:2015 (International).
Product description The test transformer calls the booster, it is the basic test equipment used by the power station, supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products, electrical equipments and insulated materials, testing the insulated level of products, discovering the insulated objection of quizzee, scaling the capacity burdened voltage Oil Immersed Testing Transformer 1 Technical index Model Capacity High Frequency Voltage Output Voltage High Frequency Voltage Output Currentm) Low Frequency Voltage input Change Tempera- ture raised 30 minute V A YD G1.5 1.5 50 30 200 7.5 500 10 YD G 3 3 50 60 200 15 500 10 YD G 5 5 50 100 200 25 500 10 YD G10 10 50 200 220/380 50/26 500 10 YD G 20 20 50 400 380 53 500 10 YD G 30 30 50 600 380 79 500 10 YD G 40 40 50 800 380 105 500 10 YD G 50 50 50 1000 380 132 500 10
Base oil sn60, 70, 100, 150, 350, 400, 500, 550, 600, 650; jet fuel a1, jp54, crude oil, bitumen 50,60/70, 90/100 & all grades of bitumen, used cooking oil, transformer oil, industrial oil, all types of grease, lng/lpg, used motor or engine oil, all types of motor oil, lubricants, additives and types of petroleum products.
Product Details: Name:Auto transformer Usage:Power Phase:Three Coil Structure:Thyroidal Rated capacity:30-3000kvaT Type:Oil immersed Input Voltage:5-35kV Output Voltage:0.4/0.23kV Material:Copper Cooling Method:Oil Natural Frequency:50/60Hz Rated voltage:20KV
1. The low-voltage winding is of cylindrical or spiral structure, with high mechanical strength and good short-circuit resistance. 2. The corrugated oil tank is adopted to replace� the oil conservator. The oil tank cover and the oil tank are all-welded along the edge or fastened with bolts, thus prolonging the service life of the transformer oil. 3. After oil removal, embroidery removal, and phosphating treatment, the product is sprayed with three times of primer and one time of finish paint inside and outside. The product is salt fog proof, damp heatproof, and fungus� proof, which can meet the special requirements of metallurgy, petrochemical system, and wet and polluted areas. It is beautiful� and reliable. 4. The transformer oil tank is� fully sealed, and� equipped with� pressure reducing valve, signal thermometer, gas relay, etc according to the standard requirements to ensure the safe operation of the transformer. 5. This series of products are beautiful in appearance, small in size, and can reduce the installation area. It is an ideal maintenance-free distribution product.
Soda ash light / dense 99.2% sodium bicarbonate caustic soda flakes 99% sodium sulphate anhydrous (ssa) 99% sodium sulphite flakes (ssf) 60% sodium metabisulphate hydrogen peroxide (h2o2) 50% formic acid 85% glacial acetic acid paraffin wax liquid paraffin (white oil) lp 100 menthol crystal fumed silica deg (di ethylene glycol) mono ethylene glycol (meg) poly ethylene glycol (peg), base oil 150n, bs 150, 600n bitumen 60/70 rpo (rubber process oil) lioh (lithium hydroxide) hco (hydrogenated castor oil) 12 hsa (hydroxy stearic acid) ferrous sulphate heptahydrate additive for lubricating oil aromatic chemicals.Exporting of chemicals & other products
Product description The test transformer calls the booster, it is the basic test equipment used by the power station, supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products, electrical equipments and insulated materials, testing the insulated level of products, discovering the insulated objection of quizzee, scaling the capacity burdened voltage Oil Immersed Testing Transformer 1 Technical index Model Capacity KVA High Frequency Voltage Output Voltage KV High Frequency Voltage Output Current mA) Low Frequency Voltage input Change Tempera- ture() raised/ 30 minute V A YD G -1.5 1.5 50 30 200 7.5 500 10 YD G 3 3 50 60 200 15 500 10 YD G-5 5 50 100 200 25 500 10 YD G10 10 50 200 220/380 50/26 500 10 YD G20 20 50 400 380 53 500 10 30 50 600 380 79 500 10 40 50 800 380 105 500 10 50 50 1000 380 132 500 10 100 100 100 500 263 1000 10 150 100 1500 500 300 1000 10 200 100 2000 500 400 1000 10
Commodity: Ammonium nitrate porous prills Molecular formula: NH4NO3 Molecule Weight: 80 CAS: 6484-52-2 UN:1942 Hazardous class:5.1 Commodity: Ammonium nitrate porous prills 1.Production of granular porous ammonium nitrate for industrial use and agricultural granular ammonium nitrate. Products with low moisture content, not easy to cake; high compressive strength, not easy to break; high oil absorption rate. Ammonium nitrate content is more than 99%, the appearance is white granular crystals, no impurities visible to the naked eye. 2. Purpose: Explosive material: granular ammonium oil explosive is made by mixing porous ammonium nitrate with raw oil. Its speed can reach more than 3 200 m/s. This explosive has strong explosive power, safe and reliable use, low price, cost saving, and can usually reduce the cost by 20%-40%. At present, this kind of explosive has been widely used in mining, construction, railway and highway construction, agricultural and water conservancy construction and national defense and other fields. 3. Product specifications: Specifications: Appearance white granule Particle size 0.5-2.5mm NH4NO3 >99.5% N >34% Oil absorption > 8% Moisture < 0.2% PH >4
Tarpaulin, tarp, pe tarp, frp, grp, grating, pultruded, composite, frp rebar, panel tanks, pond liner, geomembrane, junction box, truck cover, boat cover, tent, camping, current transformers, indoor current transformers, outdoor transformers, switch gears, oil filled tank type transformers, wound primary type transformers, bar type transformers, window type transformers.
Transformer can transformer the voltage of a network into the voltage matching the system or load and fulfill power transferring and distributing.Taking the place of transformers with silicon steel core, AMDT can be widely applied in outdoor power distribution networks systems, which is magnificently energy saving and can lessen air pollution. It is especially applicable for areas with insufficient power supply and fluctuating load and where daily maintenance is hard. Since the transformer adopts a fully sealed structure, the insulating oil and the insulating medium are not polluted by the atmosphere, so it can be carried out in a humid environment, making the ideal power distribution equipment in the urban and rural distribution networks.
S13 series of Three-phase oil Immersed Transformers,three phase transformer,three phase variable transformer,3 phase transformer,three phase power transformer,3 phase step down transformer Oil Immersed Transformer Model and Meaning Model No. Rated CapacityKVA Rated Voltage KV Connection Group Symbol Loss W No-load Current (%) Impedance Voltage% High Voltage KV Tapping Range of High Voltage Low VoltageKV No-load On Load S13-M*R-30/10 30 10 ±5%±2x2.5% 0.4 Dyn11Yyn0 80 630/600 0.30 4.0 S13-M*R-50/10 50 100 910/870 0.24 S13-M*R-80/10 80 130 1310/1250 0.22 S13-M*R-100/10 100 150 1580/1500 0.21 S13-M*R-160/10 160 200 2310/2200 0.19 S13-M*R-200/10 200 240 2730/2600 0.18 S13-M*R-250/10 250 290 3200/3050 0.17 S13-M*R-315/10 315 340 3830/3650 0.16 S13-M*R-400/10 400 410 4520/4300 0.16 S13-M*R-500/10 500 480 5410/5100 0.16 S13-M*R-630/10 630 570 6200 0.15 4.5 S13-M*R-800/10 800 700 7500 0.15 S13-M*R-1000/10 1000 830 10300 0.14 S13-M*R-1250/10 1250 970 12000 0.13 S13-M*R-1600/10 1600 1170 14500 0.13 Notes: The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents. We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you.If you want to know more about the product, please click here.