Relay , Diodes , MCB Miniature circuit breakers, copper wire and cable , flood ( street light ) , motor starter , submersible cable .
More Information Brands : Schneider, Siemens, Chint, Havells, Abb, Hager, C&S, L&T, HPL etc HSN : 85362030 Number of Poles : 1, 2, 3, 4 Poles Current Rating (Amp) : 0.5 A to 125A Curve : B Curve, C Curve, D Curve Frequency Rating : 50/60 Hz
egrand mcb series Miniature Circuit Breaker Application Legrand miniature circuit breaker is mainly suitable for overload and short circuit protection. It is especially used for illumination and distribution in industry and commerce, etc. it is of pleasing outlook & high breaking capacity, reliable performance, high inflammable resistance and shock resistance for long service life. It is within the circuit of AC 50/60HZ, rated voltage of single pole up to 230V, two, three or four poles up to 400V. It can also be for an unfrequent switchover of the circuit and illumination under normal conditions
BKN Miniature Circuit Breaker Application BKN series circuit breaker is used in lighting distribution system or motor distribution system for protection overload and short-circuits in the system. The product is neoteric in structure, reliable and excellent in performance. It has high breaking capacity, can trip quickly, and its case and items are adopted by high fire-resistant and shockproof plastic. The product, with long life, is mainly used in AC 50HZ/60HZ single-pole 230V or two, three, four poles 400V circuit for overload and short-circuit protection as well as for infrequent on-and-off switching electric equipment and lighting circuit in normal case. The products comply with IEC 60898.
* 1P, 2P, 3P, 4P * Rated Current In(A):1~125 * Rated Voltage Ue(V): 230/ 400 * Rated Frenquency(HZ): 50/60 * Rated Short Circuit Capacity Icn (A): 10000
L7 Miniature Circuit Breaker Application L7 series circuit breaker is used in lighting distribution system or motor distribution system for protection overload and short-circuits in the system. The product is neoteric in structure, reliable and excellent in performance. It has high breaking capacity, can trip quickly, and its case and items are adopted by high fire-resistant and shockproof plastic. The product, with long life, is mainly used in AC 50HZ/60HZ single-pole 230V or two, three, four poles 400V circuit for overload and short-circuit protection as well as for infrequent on-and-off switching electric equipment and lighting circuit in normal case. The products comply with IEC 60898.
Our featured products automatic transfer switch, circuit breaker, contactor, pilot light,relay, SPD, etc. with solid quality and considerable price and could equip them with enclosure. Circuit Breaker DZ47 is an automatically operated electrical switch designed to protect an electrical circuit from damage caused by overload or short circuit. Its basic function is to detect a fault condition and, by interrupting continuity, to immediately discontinue electrical flow. When a current is interrupted, the arc must be contained, cooled, and extinguished in a controlled way. So that the gap between the contacts can again withstand the voltage in the circuit. Electric ratings:Â a. AC: up to 63A, AC230/400V, AC50/60Hz; b. DC: up to 63A, DC110V/1P, DC125V/2P; Application: for protection of circuits from over-load and short-circuit; and for infrequent making and breaking of circuits under normal operation conditions, as well; Standard: IEC/EN 60898.
Product Description : Modular Circuit Breakers - xC60. Breaking Capacity as per IEC 60947-2, Icn = 15kA, upto 40A, Higher Installation Life : Energy limitation class: 3, Tropicalization: T2 - relative humidity 95% at 55C. Higher performance by Low cost : Cascading. Increase system continuty : Discrimination. Reference Temperature of 50C as per IEC60947-2. Product Specification: Brand - Schneider Model Name - A9N2P01C Current Rating - 1A Pole - Two Pole Rated operational voltage - 100V - 125V DC, 240V AC 50/60 Hz, 380V - 415V AC 50/60 Hz Rated service breaking capacity - 6kA conforming to EN/IEC 60947-2, 100V - 125V DC, 7.5kA conforming to EN/IEC 60947-2. 380V - 415V AC 50/60Hz Curve code - C Nominal Frequency - 50Hz / 60Hz Mounting Type - Clip-on Weight (in kg) - 0.250 Warranty - 2yr (on manufacturing defect)
Specification: 1.Rate current:1-63a 2.Rtated voltage:ac230/400v 3.Pole no:1p/1p+n/2p/3p/3p+n/4p 4.Curve:b/c/d 5.Breaking capacity:4.5/6/10ka About the detailed product informations, please feel free to visit our website:www.Ru-lena.Com Standard export packing
NL7-63 Series DC Miniature Circuit Breaker: PV Series Circuit Breaker:NL7-63; Number of Poles:1P, 2P, 3P, 4P; Framedegree rated current (A):63; Ue Rated operating voltage (V DC):DC12V,DC24V,DC48V,DC80V,DC125V, DC250V,DC500V,600V,DC750V,DC800V,DC1000V,DC1200V; Rated Current In (A):6-10-16-20-25-32-40-50-63; Rated Impact voltage Uimp (kV):4; Ultimate breaking capacity Icu (kA):6; Run breaking capacity Ics (%Icu):75%; Mechanical durability:20000 cycles; Electrical durability:3000 cycles; Curve type:B,C,D.
Industrial electrical wires and cables, ups systems and ancillary, junction boxes, mccb, relays and various other electrical products and equipment..We believe in quality, cost effectiveness and timely service. we try to understand and do the best as per the client requirements.
Functional design * Modern design * User-friendly ergonomics * Easy-to-understand product designation * Clearly legible On/Off marking. Compact construction * Minimum dimensions - with an installation height of 82.5 mm, one of the smallest miniature circuit breakers on the market * Maximum saving of space for comfortable wiring. Easier busbar removal * Innovative fixing slides for easy removal from a busbar combination * No laborious moving of the mounted miniature circuit breakers * "Singlefix" for removal from a bottomfixed busbar * "Twinfix" for removal from a busbar on both sides. Perfect compatibility * Multi-system compatibility of the S, SL and T product ranges, the RCCBs and DIN-rail panel products * Suitable for bottom busbar installation with previous products * Use of standard busbars * Attachments compatible with all product ranges.
GSB2 series Micro Circuit Breakers comply with IEC60898-1: Rated Isolation Voltage: up to AC500V Rated Voltage: 240V AC for 1P 415V AC for 2P, 3P and 4P Rated Current of Frame (A): 63A Rated Current (A): 1A, 3A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A Rated Ultimate Short-circuit Breaking Capacity (KA): 6 Rated Impulse Withstand Voltage or Uimp (KV): 4 Instantaneous Release: C or D Mechanical Life: 20000 times Grade of Protection: IP20 Connection Capacity: 1-25MM2 Frequency: 50Hz or 60Hz Poles: 1, 2, 3 or 4. Width of single pole: 18mm.
Pole number: 1,2,3P Rated voltage: 120/240V Rated current: 10,15,20,25,30,40,50,60A Interrupting Capability: 10KA Standard: US standard
Bis approval for isi marking as per latest is/iec 60898:2002 for assured quality and protection Green product – recyclable, low watt loss, free from hazardous material like cfc and silicon (rohs) Mcb with patented unique slr (slide latch-release) feature for tool free removal from din rail. It also allows individual mcbs to be removed from bus mounted assembly Ergonomically designed, with a user friendly lever for effortless switching To highlight exact switching position, easily recognizable color coded on-off is embedded on the attractive grey lever
DZ47 AC MCB circuit breaker series is used in lighting distribution system or motor distribution system for protecting overload and short-circuit condition. The product is light in weightreliable and excellent in performance. It has high breaking capacity up to 6kA. Its case and items are adopted with high fire-resistant and shock proof plastics. Mainly used in AC 50/60Hz single-pole 230V or two three four-pole 400V circuit for overload and short circuit protection as well as for on-off switching electric equipment and lighting circuit. The product complies with EN/IEC60898. Rated current(In) 1A, 2A, 3A, 4A, 6A, 10A, 13A, 16A, 20A, 25A ,32A ,40A, 50A, 63A, 100A Optional Rate voltage(Un) 230VAC / 415VAC / 400VAC / 415VAC Optional Breaking capacity 6kA Rated frequency 50/60Hz Tripping charateristics BCD Number of poles 1P, 2P, 3P, 4P, 1P+N, 3P+N Optional Rated impulse withstand voltage(Uimp) 4kV Electrical endurance 10000cycles Mechanical endurance 10000cycles Terminal Pillar type
Product Feature Model: EBS1B-125 MCB Standard: IEC 60947-2 Rated current In (A): 32, 40, 50, 63, 80, 100, 125 Rated voltage Ue (V):230/400 Poles:1P, 2P, 3P, 4P Rated insulation voltage Ui (V): 500 Rated impulse withstand voltage (V): 6000 Rated breaking capacity: 10kA Rated frequency: 50/60 Hz Trip characteristic:B: (3~5) C: (5~10) D: (10~20) Thermal operating limit: (1.13~1.45) Mechanical life: 20 000 Electrical life: 4000 Mount: on 35mm DIN rail Packaging Standard export carton
DZ47 mini circuit breaker 1. IEC60898-1 2. Rated current: 1~63A 3. Rated capacity: 3KA, 4.5KA For protecting cables and equipments against overload and short citcuit. 240pcs/carton (0.42X0.24X0.34 CBM) 23.5KG.
miniature circuit breaker lockout with aluminum: 1.suitable for MCB; 2.0.5g/PC; 3.100PCS/box; info@new-pv.com www.new-pv.com
Standard: IEC/EN60898-1 GB/T10963.1 Instantaneous trip type: B/C/D The number of poles: 1P/1P+N/2P/3P/3P+N/4P Rated short circuit breaking capacity (Icn): 10kA Rated working current (In): 1-63A Rated working voltage( Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated impulse withstand voltage (Uimp): 4kV Mechanical/electrical life: 10000/4000 Time