MF5700 Series Protable Gas Flow Meters General description MF5700 series mass flow meters feature cost effective ultra low power operating on 4 AAbatteries. The portable design has excellent exchangeable mechanical adaptors, easy dataaccessible and user programmable capabilities. The internal data storage can also help forpurpose flow applications. MF5700 Series Protable Gas Flow Meters Features and Applications - Ultra low power by batteries or optional external AC adaptor - Potable design with rotatable meter head and easy exchangeable mechanical adaptors - Customizable flow range with over 30:1 turn-down - Rs485 Modbus protocol ready for networking - User programmable range alarm for safety and other monitoring/control functionality - Internal data storage for additional data safety - Hygienic and oxygen safe copper body for various fluids MF5700 Series Protable Gas Flow Meters Applications Mechanics Food Tobacco Chemistry Beverage Glass Agriculture Research Pharmaceutics Instrumentation MF5700 Series Protable Gas Flow Meters Specifications * Flow Range: - MF5706: 0~ 10, 25 SLPM - MF5712: 0 ~ 200 SLPM * Turn-down Ratio: 30:1 * Accuracy: �±(2.0+0.5 FS)% * Repeatability: 0.5% * Respâ??onse Time: â?¤2 sec * Output: RS485 (Optional)
Guar Gum Types Food, Feed & Pharma Grades - Various particle sizes (very coarse to very fine). - • Various hydration rates (very slow to very fast). - • Various viscosities (1% solution in water = 50 cps to 7000 cps). - • Special deodourised grades. - • Special low microbiological count grades. Technical Grades Straight Guars: - Various particle sizes (very coarse to very fine). - Various hydration rates (very slow to very fast). - Various viscosities (1% solution in water = 50 cps to 8000 cps). - Special good Dry-Flow (Free-Flow) Guars. - Special Anti-Dusted Guars. Modified Guars and Guar Derivatives: - Fast hydrating / High Viscosity / Diesel Slurriable (particularly suitable for oil, gas and other deep well drilling and EOR operations like polymer flooding / fracturing), - Borated. - Reticulated. - Oxidised. - Depolymerised. - High water absorbance capacity. - Carboxymethyl (Anionic). - Hydroxypropyl (Nonionic). - Hydroxypropyltrimethyl chloride (Cationic). - Hydroxypropyltrimethyl chloride Hydroxypropyl (Cationic, double derivative). - Special good Dry-Flow (Free-Flow) Modified Guars / Guar Derivatives. - Special Anti-Dusted Modified Guars / Guar Derivatives. Guar gum is a fiber from the seed of the guar plant. Guar gum is used as a laxative. It is also used for treating diarrhea, irritable bowel syndrome (IBS), obesity, and diabetes; for reducing cholesterol; and for preventing “hardening of the arteries” (atherosclerosis). In foods and beverages, guar gum is used as a thickening, stabilizing, suspending, and binding agent. In manufacturing, guar gum is used as a binding agent in tablets, and as a thickening agent in lotions and creams. How does it work? Guar gum is a fiber that normalizes the moisture content of the stool, absorbing excess liquid in diarrhea, and softening the stool in constipation. It also might help decrease the amount of cholesterol and glucose that is absorbed in the stomach and intestines. There is some interest in using guar gum for weight loss because it expands in the intestine, causing a sense of fullness. This may decrease appetite. USES: Diarrhea. Adding guar gum to the tube feeding formula given to critical care patients may shorten episodes of diarrhea from about 30 days to about 8 days. High cholesterol. Taking guar gum seems to lower cholesterol levels in people with high cholesterol. Guar gum and pectin, taken with small amounts of insoluble fiber, also lower total and “bad” low-density lipoprotein (LDL) cholesterol, but don't affect “good” high-density lipoprotein (HDL) cholesterol or other blood fats called triglycerides. Diabetes. Taking guar gum with meals seems to lower blood sugar after meals in people with diabetes. By slowing stomach emptying, guar gum may also lessen after-meal drops in blood pressure that occur frequently in people with diabetes. Constipation. Irritable bowel syndrome (IBS).
1.Better than 1% accuracy 2. 0.2% of repeatability 3. 4¡á16 english letters lcd display 4. Operate with clamp on transducers 5 rs 232 interface or 1-channel isolated oct output 6. Pipe diameters from 15mm to 6000mm 7. Ni-mh battery operation of over 12 h 8.90~230vac power supply 9. Internal data logger 10. Bilingual interface in chinese and englis. 1setone carton
Drying Type Garlic Peeling Machine Garlic dividing- peeling machine is an advanced and large-scale garlic dividing -peeling equipment, which has obtained the national invention patent. No-water garlic peeling machine The machine adopts the integrated flow mode of dividing, flaking and air stripping. The raw materials and peeled products of garlic gradually come out, with small gas consumption, high output and no noise. Besides, it is equipped with garlic waste skin extrusion molding device, which is environmentally friendly and pollution-free. The successful development of this new technology has become an important mechanical equipment in the garlic processing industry . The remarkable features of the machine are as follows 1. Garlic does not need to be cut into roots, and the equipment will automatically peel garlic petals from the root. 2. Automatically split the garlic and peel it. 3. The feeding and conveying, flaking, continuous peeling and finished product output are all automatic. 4. The machine can automatically collect the waste garlic skin and extrude it into pieces, which is convenient for waste skin treatment. 5. The machine is clean and undamaged. 6. The machine also has the characteristics of low power consumption and no noise. Have full-automatic / semi-automatic garlic peeling machine ,big capacity garlic peeling production line and customized design!
We are importers and exporters of 1) recycle paper and tyre, paper product duplex, occ and ncc, ceramic tiles & sanitary wares, plastic recycle product ldpe. 2) industrial items : all kind of tarpaulin, pp corrugated sheets, ptfe lined pipes , fitting flanges , bar cutting and bending machineries, wood processing machineries, 3) oil & gas industries: all mech items pipes/ fittings // flangs and mech packages 4) soda ash, bicarb, free flowing edible and industrial salts etc 5) fmcg, atop, namkeens, foodstuff, pulses, grains, spices & besan, sarabati fresh chakki atta & maida. etc.Import export trading
FUJI developed the first infrared gas analyzer in Japan to use mass-flow sensors. Since then, we have supplied customers with various types of gas analyzers to support environmental preservation and control efforts. These efforts include measurements of atmospheric pollution and detection of low density of SOx and NOx, generated by incinerating facilities and boilers. FUJI's gas analyzers are widely used to monitor the atmosphere to help maintain a cleaner natural environment.
Inert Gas Flow Meter
Residential Diaphragm Gas Meter ITRON (MID approved) Steel Version Basic Features 3 Compact size: 1.2 dm cyclic volume Range: G1.6, G2.5, G4 EN 1359 & O.I.M.L compliance Design Long -term accuracy & safety Ready for remote reading & data management Quality World-class, ISO9001 certified, European Engineering and Manufacturing APPLICATION The ITRON, with an installed base of over 30 million units, is a versatile meter that makes it the preferred choice of many large utilities world-wide. METROLOGY The ITRON meets O.I.M.L, EN 1359 and MID (certificate delivered by the LNE), and more than 25 national metrological standards (DVGW,NMI Class 1....). Its design and the careful choice of materials enable the ITRON to meet the highest demand in international markets in terms of accuracy and long-term stability. During the preliminary test controls on the sonic nozzle test benches, all meters are tested at Qmin, 0.2 Qmax and Qmax. OPERATING PRINCIPLE The ITRON is a positive displacement diaphragm gas meter with a stand-alone twin chamber measuring unit. The twin chambers are each fitted with a flexible and gas-tight diaphragm which is moved by the differential between the inlet and outlet pressure. The Gas enters one side of the diaphragm pan while on the other side it comes out through a separate port on the valve. When one side is full, the rotating mono-valve moves on to the next position, allowing the gas to fill the empty side. A transmission gear and a mechanical coupling or stuffing box transfer the reciprocating motion to the mechanical retrofitable index. The measuring unit is housed in a robust gas-tight casing. CONSTRUCTION With its casing in steel, high protection against corrosion is ensured by 500 hours salt fog spray test resistant cataphoresis treatment. The aluminum version can withstand up to 1000 hours salt fog spray test. The extreme strength of the case joint is achieved by rolling the belt & compressing the flanges into contact with a sealant applied between the faces. This forms a joint which is both gas-tight and fire- resistant. MEASURING UNIT The achievement of the fixed stroke mechanism is the result of precision and high quality automation, and eliminates the need for an adjustable tangent. This confines all registration adjustments to the accessible change wheels behind the index. The long life synthetic diaphragms, coupled to the well-proven movement design, combine to give excellent stability and accuracy during the whole life of the metre. All materials have been selected for their superior resistance to chemicals and gas. The valve and the grid, thanks to a special Bakelite formulation, enjoy high gliding properties and are protected against premature wear. Finally, a back-run stop prevents the metre from running backwards in case of tampering. INDEX The metres are available with metric or cubic inch indexes. They come with a permanent magnet for pulse generation and can be retrofitted with a pulse transmitter. Ip54 and Ip67 versions are available for specific environments. QUALITY ASSURANCE Quality assurance procedures- such as ISO 9001- and strict controls throughout the manufacturing process ensure a very high quality level. APPLICATION The ITRON, with an installed base of over 30 million units, is a versatile meter that makes it the preferred choice of many large utilities world-wide. METROLOGY The ITRON meets O.I.M.L, EN 1359 and MID (certificate delivered by the LNE), and more than 25 national metrological standards (DVGW,NMI Class 1....). Its design and the careful choice of materials enable the ITRON to meet the highest demand in international markets in terms of accuracy and long-term stability. During the preliminary test controls on the sonic nozzle test benches, all meters are tested at Qmin, 0.2 Qmax and Qmax. OPERATING PRINCIPLE The ITRON is a positive displacement diaphragm gas meter with a stand-alone twin chamber measuring unit. The twin chambers are each fitted with a flexible and gas-tight diaphragm which is moved by the differential between the inlet and outlet pressure. The Gas enters one side of the diaphragm pan while on the other side it comes out through a separate port on the valve. When one side is full, the rotating mono-valve moves on to the next position, allowing the gas to fill the empty side. A transmission gear and a mechanical coupling or stuffing box transfer the reciprocating motion to the mechanical retrofitable index. The measuring unit is housed in a robust gas-tight casing. CONSTRUCTION With its casing in steel, high protection against corrosion is ensured by 500 hours salt fog spray test resistant cataphoresis treatment. The aluminum version can withstand up to 1000 hours salt fog spray test. The extreme strength of the case joint is achieved by rolling the belt & compressing the flanges into contact with a sealant applied between the faces. This forms a joint which is both gas-tight and fire- resistant. MEASURING UNIT The achievement of the fixed stroke mechanism is the result of precision and high quality automation, and eliminates the need for an adjustable tangent. This confines all registration adjustments to the accessible change wheels behind the index. The long life synthetic diaphragms, coupled to the well-proven movement design, combine to give excellent stability and accuracy during the whole life of the metre. All materials have been selected for their superior resistance to chemicals and gas. The valve and the grid, thanks to a special Bakelite formulation, enjoy high gliding properties and are protected against premature wear. Finally, a back-run stop prevents the metre from running backwards in case of tampering. INDEX The metres are available with metric or cubic inch indexes. They come with a permanent magnet for pulse generation and can be retrofitted with a pulse transmitter. Ip54 and Ip67 versions are available for specific environments. QUALITY ASSURANCE Quality assurance procedures- such as ISO 9001- and strict controls throughout the manufacturing process ensure a very high quality level. Prepaid Gas Meter Sensus Meters satndars
Consists of paper as typically generated by offices, containing primarily white and coloured groundwood free paper, free of unbleached fibre. May include a small percentage of carbonless paper. Prohibitive materials may not exceed...........................1% Total Outthrows may not exceed.................................5%
Item Hot Dipped Galvanized Round Steel Pipe/GI Pipe/Galvanised Tube OD 20~405mm in theory Thickness 1.2~15.7mm Length Any Length Below 16 Meter Standard GB,ASTM,BS,EN,JIS Material Chinese Grade, Q195, Q215 Q235, Q345 ASTM, Grade B,Grade C,Grade D,Grade 50 EN, S185,S235JR,S235JO,E335,S355JR,S355J2 JIS, SS330,SS400,SPFC590 Application Used For Water, Gas, Stream, Combustible Fluids And Other Liquid Delivery Ends Plain, Beveled, Thread With Couplings Or Sockets; Plastic Caps And Steel Rings Can Be Provided If Possible Surface Bared, Galvanized, Oiled, Color Paint, 3PE; Or Other Anti-corrosive Treatment Technique Hot Rolled Or Cold Rolled ERW Package Covered With Tarpaulin, Containers Or In Bulk