Model No.: JTD 12kv 1250A 20KA vacuum interrupter for Solid embedded poles Rated voltage: 12 KV Rated current: 1250A Rated power frequency withstand voltage (1 min): 42 KV Rated lightning impulse withstand voltage: 75 KV Rated short circuit breaking current: 20KA Rated short circuit making current(peak value): 50KA Breaking operations under rated short circuit breaking current: 30 times Rated short time withstand current: 20KA Rated withstand current(peak value): 50KA Rated duration of short circuit: 4 s Mechanical life: 20,000 times Closing force due to bellows and atmosphere: 70±40 N Force required to hold contacts opening at full stroke: 120±50 N Circuit resistance at lowest rated contacts force: =35µO Storage life: 20 years Limiting abrasion of contacts: 3 mm Weight of moveable parts: =0.7kg Mechanical requiements of vacuum circuit breaker Clearance between opening contacts: 7±1 mm Average opening speed: 1.0±0.25 m/s Average closing speed: 0.65±0.15 m/s Rated contacts pressure: 1600±100 N Contacts bouncing duration at closing operation: =2 ms Contacts re-bouncing clearance at opening operation: =2 mm Synchronism of three phases: =1 ms
Model No.: TD 12kv 1250A 25KA (JUC613) vacuum interrupter for VCB Main technical parameters Rated voltage: 12 KV Rated current: 1250A Rated power frequency withstand voltage: 42 KV Rated lightning impulse withstand voltage: 75 KV Rated short circuit breaking current: 25KA Rated short circuit making current(peak value): 63KA Breaking operations under rated short circuit breaking current: 30 times Rated short time withstand current: 25KA Rated withstand current(peak value): 63KA Rated duration of short circuit: 4S Mechanical life: 20,000 times Closing force due to bellows and atmosphere: 120±50N Force required to hold contacts opening at full stroke: 190±50N Circuit resistance at lowest rated contacts force Storage life: 20 years Limiting abrasion of contacts: 3 mm Mechanical requiements of vacuum circuit breaker Clearance between opening contacts: 11±1mm Average opening speed(Contacts closing position~75% contacts opening distance): 1.1±0.2 m/s Average closing speed(30% contacts opening distance~contacts closing position): 0.6±0.2 m/s Rated contacts pressure: 2000±200N Contacts bouncing duration at closing operation: �2ms Contacts re-bouncing clearance at opening operation: �2mm Synchronism of three phases: �1ms
Model No.: TD 12kv 1250A 31.5KA (JUC618) vacuum interrupter for VCB Main technical parameters Rated voltage: 12 KV Rated current: 1250A Rated power frequency withstand voltage: 42 KV Rated lightning impulse withstand voltage: 75 KV Rated short circuit breaking current: 31.5KA Rated short circuit making current(peak value): 80KA Breaking operations under rated short circuit breaking current: 30 times Rated short time withstand current: 31.5KA Rated withstand current(peak value): 80KA Rated duration of short circuit: 4S Mechanical life: 20,000 times Closing force due to bellows and atmosphere: 120±50N Force required to hold contacts opening at full stroke: 190±50N Circuit resistance at lowest rated contacts force: =20µO Storage life: 20 years Limiting abrasion of contacts: 3 mm Mechanical requiements of vacuum circuit breaker Clearance between opening contacts: 11±1 mm Average opening speed(Contacts closing position~75% contacts opening distance): 1.1±0.2 m/s Average closing speed(30% contacts opening distance~contacts closing position): 0.6±0.2 m/s Rated contacts pressure: 3150±200 N Contacts bouncing duration at closing operation: =2 ms Contacts re-bouncing clearance at opening operation: =2 mm Synchronism of three phases: =1 ms
Model No.: TD 12kv 1250A 31.5KA (JUC619A) vacuum interrupter for VCB Main technical parameters Rated voltage: 12 KV Rated current: 1250A Rated power frequency withstand voltage: 48 KV Rated lightning impulse withstand voltage: 85 KV Rated short circuit breaking current: 31.5KA Rated short circuit making current(peak value): 80KA Breaking operations under rated short circuit breaking current: 30 times Rated short time withstand current: 31.5KA Rated withstand current(peak value): 80KA Rated duration of short circuit: 4 s Mechanical life: 10,000 times Closing force due to bellows and atmosphere: 120±50 N Force required to hold contacts opening at full stroke: 190±50 N Circuit resistance at lowest rated contacts force: =20µO Storage life: 20 years Limiting abrasion of contacts: 3 mm Mechanical requiements of vacuum circuit breaker Clearance between opening contacts: 11±1 mm Average opening speed(Contacts closing position~75% contacts opening distance): 1.1±0.2 m/s Average closing speed(30% contacts opening distance~contacts closing position): 0.6±0.2 m/s Rated contacts pressure: 3150±200 N Contacts bouncing duration at closing operation: =2 ms Contacts re-bouncing clearance at opening operation: =2 mm Synchronism of three phases: =1 ms * It Needs additional insultating protection.
Model No.: TD 12kv 1250A 25KA (JUC613) vacuum interrupter for VCB Main technical parameters Rated voltage: 12 KV Rated current: 1250A Rated power frequency withstand voltage: 42 KV Rated lightning impulse withstand voltage: 75 KV Rated short circuit breaking current: 25KA Rated short circuit making current(peak value): 63KA Breaking operations under rated short circuit breaking current: 30 times Rated short time withstand current: 25KA Rated withstand current(peak value): 63KA Rated duration of short circuit: 4S Mechanical life: 20,000 times Closing force due to bellows and atmosphere: 120±50N Force required to hold contacts opening at full stroke: 190±50N Circuit resistance at lowest rated contacts force: =20µO Storage life: 20 years Limiting abrasion of contacts: 3 mm Mechanical requiements of vacuum circuit breaker Clearance between opening contacts: 11±1mm Average opening speed(Contacts closing position~75% contacts opening distance): 1.1±0.2 m/s Average closing speed(30% contacts opening distance~contacts closing position): 0.6±0.2 m/s Rated contacts pressure: 2000±200N Contacts bouncing duration at closing operation: =2ms Contacts re-bouncing clearance at opening operation: =2mm Synchronism of three phases: =1ms
HCJ3 12KV 630A vacuum interrupter for vacuum contactor 1. Brief introduction The interrupter adoption porcelain and ceramics makes to insulate the outer shell. Contact is WCCu metal alloy material advanced technique of adoption Including bulk small. Breaking the abiliting strong the life span is long, maintenanle is simple ,no explosion dangerous, no contaminate and the noise is low . The pack vacuum contactor can operate the ebery kind of electric appliances equipments, and fuse match f-c cabinet 2. Vacuum Tube main technique parameter Rated voltage: 12 kv Rated cureent: 630A Rated making current: 6.3KA Rated breaking current: 5.04KA Limiting breaking current: 6.3KA Rated short-time withstand current: 6.3KA Rated short-time withstand voltage: 42 kv Rated lighting impulse voltage: 75 kv Circuit resistance at lowest rated contacts force: �80μΩ Electrical life: 250,000 times Mechanical life: 5000,000 times Closing force due to bellows and atmosphere: 70±20 N Force required to hold contacts open at full stroke: 100±30 N Limiting abrasion of contacts: 3 mm Internal gas pressure: �1.33�10-3 Pa Storage life: 20 years
Vacuum Circuit Breaker HVD1-12KV 1250A 25KA VCB with copper parts 210mm phase distance HVD1-12(VS1-12) type indoor AC HV vacuum circuit breaker (hereinafter referred to as circuit breaker) are suitable for 12kV air-insulated indoor switchgears, used as protection and control unit of power equipment of industrial& mining enterprise. Due to the super excellence, it is especially for location where requires the frequent operation of rated working current or multi breaking short circuit current. The circuit breaker adopts the integrated design of operating mechanism and circuit breaker body, servers as not only fixed installation, but also the handcart unit through equipping with a special propelling mechanism. 2. Service conditions 3.1 Environment temperature:-15®C~+40®C; 3.2 Environment humidity: Daily average relative humidity:95%, monthly average relative humidity:90%; Daily average saturated vapor pressure:2.210-3Mpa,monthly average saturated vapor pressure:1.810-3Mpa; 3.3 Altitude: Not exceed 1000m; 3.4 Earthquake intensity: Not exceed°ree; 3.5 Service location: No water, flammable or explosive matter, chemical corrosive gas or drastic vibration. 1.Main specifications and technical parameters Rated voltage: 12 kv Rated lightning impulse withstand voltage(1min): 75 kv Rated short-time power frequency withstand voltage (1min): 42 kv Rated short-circuit breaking current: 25KA Rated current: 1250A Rated peak withstand current: 63KA Rated shorted-time withstand current: 25KA Rated shorted-time making current(peak): 63KA Power frequency withstand voltage of secondary circuit(1min): 2000 v Opening time(rated voltage): 20~50 ms Closing time(rated voltage): 30~70 ms Rated short-circuit current breaking times: 50(40kA 30) times Mechanical life: 30,000 times
HCJ3 12KV 630A vacuum interrupter for vacuum contactor 1. Brief introduction The interrupter adoption porcelain and ceramics makes to insulate the outer shell. Contact is WCCu metal alloy material advanced technique of adoption Including bulk small. Breaking the abiliting strong the life span is long, maintenanle is simple ,no explosion dangerous, no contaminate and the noise is low . The pack vacuum contactor can operate the ebery kind of electric appliances equipments, and fuse match f-c cabinet 2. Vacuum Tube main technique parameter Rated voltage: 12 kv Rated cureent: 630A Rated making current: 6.3KA Rated breaking current: 5.04KA Limiting breaking current: 6.3KA Rated short-time withstand current: 6.3KA Rated short-time withstand voltage: 42 kv Rated lighting impulse voltage: 75 kv Circuit resistance at lowest rated contacts force: =80µO Electrical life: 250,000 times Mechanical life: 5000,000 times Closing force due to bellows and atmosphere: 70±20 N Force required to hold contacts open at full stroke: 100±30 N Limiting abrasion of contacts: 3 mm Internal gas pressure: =1.33×10-3 Pa Storage life: 20 years
Model No.: TD 12kv 1600A 31.5KA (JUC618A) vacuum interrupter for VCB Main technical parameters Rated voltage: 12 KV Rated current: 1600A Rated power frequency withstand voltage: 42 KV Rated lightning impulse withstand voltage: 75 KV Rated short circuit breaking current: 31.5KA Rated short circuit making current(peak value): 80KA Breaking operations under rated short circuit breaking current: 30 times Rated short time withstand current: 31.5KA Rated withstand current(peak value): 80KA Rated duration of short circuit: 4 s Mechanical life: 20,000 times Closing force due to bellows and atmosphere: 120±50 N Force required to hold contacts opening at full stroke: 190±50 N Circuit resistance at lowest rated contacts force: =20µO Storage life: 20 years Limiting abrasion of contacts: 3 mm Mechanical requiements of vacuum circuit breaker Clearance between opening contacts: 11±1 mm Average opening speed(Contacts closing position~75% contacts opening distance): 1.1±0.2 m/s Average closing speed(30% contacts opening distance~contacts closing position): 0.6±0.2 m/s Rated contacts pressure: 3150±200 N Contacts bouncing duration at closing operation: =2 ms Contacts re-bouncing clearance at opening operation: =2 mm Synchronism of three phases: =1 ms
Model No.: TD 12kv 1600A 31.5A (JUC619) vacuum interrupter for VCB Main technical parameters Rated voltage: 12 KV Rated current: 1600A Rated power frequency withstand voltage: 48 KV Rated lightning impulse withstand voltage: 85 KV Rated short circuit breaking current: 31.5KA Rated short circuit making current(peak value): 80KA Breaking operations under rated short circuit breaking current: 30 times Rated short time withstand current: 31.5KA Rated withstand current(peak value): 80KA Rated duration of short circuit: 4 s Mechanical life: 10,000 times Closing force due to bellows and atmosphere: 120±50 N Force required to hold contacts opening at full stroke: 190±50 N Circuit resistance at lowest rated contacts force: =20µO Storage life: 20 years Limiting abrasion of contacts: 3 mm Mechanical requiements of vacuum circuit breaker Clearance between opening contacts: 11±1 mm Average opening speed(Contacts closing position~75% contacts opening distance): 1.1±0.2 m/s Average closing speed(30% contacts opening distance~contacts closing position): 0.6±0.2 m/s Rated contacts pressure: 3150±200 N Contacts bouncing duration at closing operation: =2 ms Contacts re-bouncing clearance at opening operation: =2 mm Synchronism of three phases: =1 ms * It Needs additional insultating protection.
Vacuum interrupters Hanguang electron device factory(4404), has been manufacturing wide range of high quality vaccum interrupters for medium and high voltage switch circle in china since 1969's. Outstanding vacuum interrupter manufactleader techniques used by hanguang result in the highest quality and the largest voltage range of vacuum interrupters available today.
VACCUM CIRCUIT BREAKER ALL TYPE OF ABB VACCUM CIRCUIT BREAKER VD4 12.12.25 , VD4 12.12.40, VD4 07.12.25.... MANY MORE 11 KV , 33KV . VD4Medium voltage vacuum circuit-breaker12 kV - 1250...4000 A - 63 kA36/40.5 kV - 630...3150 A - 16...40 kAMedium Voltage Products The VD4 are a synthesis of the renownedtechnology in designing and constructing vacuuminterrupters embedded in resin poles, and ofexcellency in design, engineering and productionof medium voltage circuit-breakers.Embedding the interrupter in resin makes thecircuit-breaker poles particularly sturdy andprotects the interrupter against shocks, accumula-tion of dust and humidity.The vacuum interrupter houses the contacts andmakes up the interrupting chamber.
Toshiba Cv-6ha , Contactor Magnetic, Ctry.mfg Toshiba Part Cv-6ha, 100-110 V Ac/dc, 50/60 Hz, 7.2 Kv, 6.6-3.3 Kv Operational Voltage, 400a, Draw-out Type, Vacuum Contactor With Clf Fuse. The Toshiba HCV-6KAU and HCV-6KALU vacuum contactors described in this manual are suitable for use on systems of 7.2kV 720A 7.2kA. Arc interruption is accomplished inside sealed vacuum interrupters mounted on track-resistant insulators. Vacuum interrupters use low-surge contact materials, which exhibit low current chopping levels reducing switching over-voltage.
We can provide all series vacuum interrupter (vacuum chamber) for outdoor and indoor circuit breaker, embedded poles for 12/24/40.5kv circuit breaker, load breaking switch, load breaking switch.
6.6KV to 40KV Vacuum Interrupter for Vacuum Circuit Breaker Indoor/Outdoor Panel
HVJ30 1.14kv vacuum contactor 1250A HVJ30-1.14/1250 series AC vacuum contactor is applicable for AC 50HZ power system of rated voltage 1.14KV and rated current up to 1000 A1250Ato open and close circuit, start and control AC motor frequently. It is suitable for composed magnetic starter with various protective devices (JDB electronic integrated protector, JR9 type over current protection device, resistance-capacitance absorbers). It is particularly suitable for compose a explosion-proof magnetic starter and large mineral switchgear. Rated voltage: 1.14 kv Rated current: 1250A Making capacity(A): 5000100 times Breaking capacity(A): 450010 times Limit breaking capacity(A): 50003 times Electrical life times(AC3): 600,000 times Electrical life times(AC4): 6,000 times Mechanical life times: 1,000,000 times Rated operating frequency (AC3): 600 times /h Rated operating frequency (AC4): 120 times /h Short-time operating frequency20s: 1000 times /h Contacts separation: 2.8±0.1 mm Over travel: 1.0±0.1 mm
TKZKD Vacuum Interrupter Test Set without removing direct quantitative measuring vacuum degree of vacuum switch interrupter. With the quantitative measurement means can not only measure the degree of vacuum of vacuum switch whether is within the normal range more importantly for some vacuum switches which leak faster compared with the measuring results of past years its life can generally be inferred prevent accidents. This product is compact lightweight and compact models short test time reliable measurement results good stability high precision fully functional is the ideal instrument for quantitative measuring vacuum switches. Features 1. Can make quantitative measurement for vacuum degree of all models vacuum switch arc-chutes. 2. Need not disassemble the vacuum switch during the field test. 3. High precision. 4. With LCD easy to operate. 5. Can save print and review the test results. 6. The device with RS232 communication interface connect with the PC can download the vacuum degree-ion current curve can estimate the life. 7. Light in weight easy to carry.
ntroduction TKZKD Vacuum Interrupter Test Set without removing direct quantitative measuring vacuum degree of vacuum switch interrupter. With the quantitative measurement means can not only measure the degree of vacuum of vacuum switch whether is within the normal range more importantly for some vacuum switches which leak faster compared with the measuring results of past years its life can generally be inferred prevent accidents. This product is compact lightweight and compact models short test time reliable measurement results good stability high precision fully functional is the ideal instrument for quantitative measuring vacuum switches. Features 1. Can make quantitative measurement for vacuum degree of all models vacuum switch arc-chutes. 2. Need not disassemble the vacuum switch during the field test. 3. High precision. 4. With LCD easy to operate. 5. Can save print and review the test results. 6. The device with RS232 communication interface connect with the PC can download the vacuum degree-ion current curve can estimate the life. 7. Light in weight easy to carry.
TKZKD Vacuum Interrupter Test Set without removing direct quantitative measuring vacuum degree of vacuum switch interrupter. With the quantitative measurement means can not only measure the degree of vacuum of vacuum switch whether is within the normal range more importantly for some vacuum switches which leak faster compared with the measuring results of past years its life can generally be inferred prevent accidents. This product is compact lightweight and compact models short test time reliable measurement results good stability high precision fully functional is the ideal instrument for quantitative measuring vacuum switches. Features 1. Can make quantitative measurement for vacuum degree of all models vacuum switch arc-chutes. 2. Need not disassemble the vacuum switch during the field test. 3. High precision. 4. With LCD easy to operate. 5. Can save print and review the test results. 6. The device with RS232 communication interface connect with the PC can download the vacuum degree-ion current curve can estimate the life. 7. Light in weight easy to carry.
TD 12kv 1250A 31.5KA (JUC618) vacuum interrupter for VCB Main technical parameters Rated voltage: 12 KV Rated current: 1250A Rated power frequency withstand voltage: 42 KV Rated lightning impulse withstand voltage: 75 KV Rated short circuit breaking current: 31.5KA Rated short circuit making current(peak value): 80KA Breaking operations under rated short circuit breaking current: 30 times Rated short time withstand current: 31.5KA Rated withstand current(peak value): 80KA Rated duration of short circuit: 4S Mechanical life: 20,000 times Closing force due to bellows and atmosphere: 120±50N Force required to hold contacts opening at full stroke: 190±50N Circuit resistance at lowest rated contacts force: â?¤20μΩ Storage life: 20 years Limiting abrasion of contacts: 3 mm Mechanical requiements of vacuum circuit breaker Clearance between opening contacts: 11±1 mm Average opening speed(Contacts closing position~75% contacts opening distance): 1.1±0.2 m/s Average closing speed(30% contacts opening distance~contacts closing position): 0.6±0.2 m/s Rated contacts pressure: 3150±200 N Contacts bouncing duration at closing operation: â?¤2 ms Contacts re-bouncing clearance at opening operation: â?¤2 mm Synchronism of three phases: â?¤1 ms