ALSTOM GBCDG31FF002SDCH IDMT 2 O/C & 1 E/F RELAY SELF POWERED. MODEL No CDG31FF002SDCH RELAY TYPE CDG 31 APPLICATION 2 O/C + 1 E/F BURDEN / D.M.T 3 VA / 3 SEC. C.T. SECONDARY 5 AMP C.T. CASE SIZE 3D VERT. CONTACTS (S/R OR H/R) 2 N/O 2 N/C H/R E/F SETTING 0.5 - 2 Amps. FLAG YES FREQUENCY 50 HZ MOUNTING FLUSH O/C SETTING 2.5 - 10 Amps. NAME PLATE RFG9126 903 OUTLINE DRAWING MFJ 013 WIRING DIAGRAM MFDZ801-103-1
ALSTOM GBCDG31FF003SDCH IDMT 2 O/C & 1 E/F RELAYS Technical specification RELAY MODEL NO CDG31FF003SDCH Relay type CDG 31 CASE SIZE 3D VER. APPLICATION 2 O/C & 1 E/F CURR.SETTING O/C .5 TO 2 AMPS CURR.SETTING E/F .2 TO .8 AMPS CONATCTS 2M 2B H/R OUTPUT CONTACTS 2M 2B H/R TAPS STD FREQUENCY 50 HZ C.T.SECONTARY 1 AMPS BURDEN / OPERATING TIME 3 VA / 3 SECS. NAME PLATE RFG9126 902 OUTLINE DRAWING MFJ 013 WIRING DIAGRAM MFDZ801.103-1
GBCDG31FF021SBCH IDMT 2 O/C & 1 E/F RELAYS SPL 150 HZ. Technical specification Relay model No CDG31FF021SBCH Relay type CDG 31 Special Case size 3D V 20T Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Current setting - E/F 0.5 to 2 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R Taps Std BURDE / D.M.T 3 VA / 3 Secs C.T.Secondary 5 amps Frequency 150 Hz Flag Yes Mounting Flush Note to test:Relay to test 150 Hz. refer test inst. Name Plate RFG9126 903 Outline drawing MFJ 013 Wiring diagram MFDZ 801.101-1
GBCDG61EG042SHCH IDMT 2 O/C & 1 E/F RELAY WITH HIGH SET Technical specification Relay model no- CDG61EG042SHCH Relay type - CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting - O/C - 0.5 to 2 amps Contacts - 2M2B H/R 2M S/R Output contacts - 2M2B H/R 2M S/R C.T.Secondary - 1 amps Frequency - 50 Hz Burden - 3 VA Operating time - 3 secs Current setting - E/F - 0.2 to 0.8 amps High set - O/C Setting- 4 to 16 amps High set - E/F Setting - 1 to 4 amps High set - CAG 13 Name plate - RFG9126 902 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.29-1
GBCDG61EG046SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no - CDG61EG046SGCH Relay type - CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting O/C- 2.5 to 10 amps Contacts / Output contacts 3M S/R / 2M S/R C.T.Secondary - 5 amps Frequency - 50 Hz Burden - 3 VA Operating time - 3 secs Current setting - E/F - 1 to 4 amps High set - O/C Setting- 25 to 100 amps High set - E/F Setting- 10 to 40 amps High set - CAG 13 Name plate - RFG9126 904 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.27-1
GBCDG61EG044SHCH IDMT 3 O/C RELAY WITH HIGH SET CAG 13 Technical specification Relay model no - CDG61EG044SHCH Relay type - CDG 61 Case size - 3D H 30T Application - 3 O/C Current setting - 0.5 to 2 amps Contacts / Output contacts - 2 N/O 2 N/C H/R C.T.Secondary - 1 amps Frequency - 50 Hz Burden - 3 VA Operating time - 3 secs High set - O/C Setting - 4 to 16 amps High set - CAG 13 High set contacts - 2 N/O S/R Name plate - RFG9126 771 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.29-1
GBCDG61EG054SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no - CDG61EG054SGCH Relay type - CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting - O/C - 0.5 to 2 amps Contacts - 3 N/O S/R Output contacts - 2 N/O S/R C.T.Secondary - 1 amps Frequency - 50 Hz Burden / Operating time - 3 VA / 1.3 secs Current setting - E/F 0.2 to 0.8 amps High set - O/C setting 4 to 16 amps High set - E/F setting 2 to 8 amps High set CAG 13 Name plate RFG9125 902 Outline drawing MFJ 014 Wiring diagram - MADZ 821.27-1
GBCDG61EG057SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no - CDG61EG057SGCH Relay type - CDG 61 Case size - 3D HOR. Application - 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R C.T.Secondary 1 amps Frequency 50 Hz Burden / Operating time 3 VA / 3 secs Current setting - E/F 0.2 to 0.8 amps High set - O/C setting 4 to 16 amps High set - E/F setting 1 to 4 amps High set CAG 13 Name plate RFG9126 902 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
GBCDG61EG058SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no - CDG61EG058SGCH Relay type CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting - O/C - 2.5 to 10 amps Contacts - 3 N/O S/R Output contacts - 2 N/O S/R C.T.Secondary - 5 amps Frequency - 50 Hz Burden / Taps - 3 VA / Std Operating time - 1.3 Secs Current setting - E/F - 0.5 to 2 amps High set - O/C Setting - 25 to 100 amps High set - E/F Setting - 10 to 40 amps High set / High set cont. - CAG 13 / 2 N/O S/R Name plate - RFG9125 903 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.27-1
Gbcdg61eg101zmch Idmt 3 O/c or 2o/c& 1 E/f Relay With Hi Model No : Cdg61eg101zm(M) Cdg61/cag17(Mrk-iii) Application - 3 O/c Burden / D.m.t - 3 Va / 3 Sec. C.t. Secondary - 5 Amp C.t. Case Size - 3d Horz. Contacts (S/r or H/r) - 2 N/o S/r Flag - Yes Frequency - 50 Hz High Set Type - Cag17 Highset Contacts - 2m S/r Highset O/c Setting - 12.5 - 100 Amps. Mounting - Flush O/c Setting - 2.5 - 10 Amps. Name Plate - Rfg9126 774 Outline Diagram - Mfj 014 Wiring Diagram - Madz821.31
Gbcdg61eg101znch Idmt 3 O/c or 2o/c& 1 E/f Relay With Hi Model No : Cdg61eg101zn(M) Cdg61/cag17(Mrk-iii) Application - 3 O/c Burden / D.m.t - 3 Va / 3 Sec. C.t. Secondary - 5 Amp C.t. Case Size - 3d Horz. Contacts (S/r or H/r) - 2 N/o 2 N/c H/r Flag - Yes Frequency - 50 Hz High Set Type - Cag17 Highset Contacts - 2m S/r Highset O/c Setting - 12.5 - 100 Amps. Mounting - Flush O/c or O/v Setting - 2.5 - 10 Amps. Name Plate Rfg9126 774 Outline Diagram Mfj 014 Wiring Diagram Madz821.32
GBCDG61EG101ZRCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical Specification Model No - CDG61EG101ZRCH Relay Type - CDG61/CAG17(MRK-III) Application - 2 O/C + 1 E/F Case Size - 3D Horz C.T. Secondary - 5 Amp C.T. O/C Setting - 2.5 - 10 Amps. E/F Setting - 0.5 - 2 Amps Contacts - 2 N/O S/R Flag - Yes Frequency - 50 Hz Burden / D.M.T - 3 Va / 3 Sec High Set Type / Conts. - CAG17 / 2 N/O S/R Highset O/C Setting - 12.5 - 100 Amps. HighSet E/F Setting - 5 - 40 Amps Mounting - Flush Name Plate - RFG9126 903 Outline Diagram - MFJ 014 Wiring Diagram - MADZ821.31
GBCDG61EG101ZSCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI TECHNICAL SPECIFICATION Model No - CDG61EG101ZSCH CDG61/CAG17(MRK-III) Application - 2 O/C + 1 E/F Case Size - 3D Horz C.T. Secondary - 5 Amps O/C Setting - 2.5 - 10 Amps. Frequency / Tap - 50 HZ / Std Burden / D.M.T - 3 Va / 3 Sec Contacts - 2 N/O 2 N/C H/R E/F Setting - 0.5 - 2 Amps. Flag - Yes High Set Type / Contacts - CAG17 / 2 N/O S/R HighSet E/F Setting - 5 - 40 Amps HighSet O/C Setting - 12.5 - 100 Amps. Mounting - Flush Name Plate - RFG9126 903 Outline Diagram - MFJ 014 Wiring Diagram - MADZ821.32
GBCDG61EG102ZMCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Model No : CDG61EG102ZMCH CDG61/CAG17(MRK-III) APPLICATION - 3 O/C BURDEN - 3 VA C.T. SECONDARY - 1 AMP CT. CASE SIZE - 3D HORZ. CONTACTS (S/R OR H/R) - 2 N/O S/R D.M.T - 3 SEC. FLAG - YES FREQUENCY - 50 HZ HIGH SET TYPE - CAG17 HIGHSET CONTACTS - 2M S/R HIGHSET O/C SETTING - 2.5 - 20 Amps. MOUNTING - FLUSH O/C SETTING - 0.5 - 2 Amps. Name Plate RFG9126 771 Outline drawing MFJ 014 Wiring Diagram MADZ821.31
Cucumber : 1. Anti-tumor: cucumber contains cucurbitacin C has the role of improving the immune function, can achieve the purpose of anti-tumor. In addition, the substance can also treat chronic hepatitis 2. Anti-aging: old cucumber is rich in vitamin E, can play a longevity, anti-aging effect; cucumber in the cucumber enzyme, has a strong biological activity, can effectively promote the body's metabolism. Smear the skin with a cucumber Daozhi, with moisturizing effect, stretch the effect of wrinkles 3. Alcoholism: Cucumber contains alanine, arginine and glutamine on liver patients, especially in patients with alcohol cirrhosis have some adjuvant therapy, can prevent alcoholism 4. Hypoglycemic: cucumber contains glucoside, fructose and so do not participate in the usual sugar metabolism, so the diabetic cucumber instead of starchy food to eat, blood sugar will not increase, or even lower 5. weight loss strong body: cucumber contains propionic acid, can inhibit the conversion of carbohydrates into fat. In addition, the cucumber in the promotion of human intestinal corrupt substances in the exclusion of drugs, as well as lower cholesterol have a certain role, can keep fit.
ALSTOM GBCDG61EG040SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Relay Technical specification Relay model no CDG61EG040SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Aux.Contacts With Flag 3M S/R Output contacts 2M S/R C.T.Secondary 5 amps Frequency 50 Hz Burden 3 VA Operating time 1.3 secs Current setting - E/F 0.5 to 2 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 5 to 20 amps High set conts.With flag CAG 13 / 2M S/R Name plate RFG9125 903 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
ALSTOM GBCDG61EG041SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG041SGCH Relay type CDG 61 Case size 3D H 30T Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Contacts / Output contacts 3M S/R / 2M S/R C.T.Secondary 5 amps Frequency 50 Hz Burden 3 VA Operating time 3 secs Current setting - E/F 0.5 to 2 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 5 to 20 amps High set CAG 13 Name plate RFG9126 903 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
Fly Ash: Fly Ash is by product generated during combustion of coal, and comprises the fine particles that rise with the flue gases. Ash which is collected from the bottom is termed bottom ash. Fly ash is collected by electrostatic precipitators or other particle filtration equipment before the flue gases reach the chimneys of coal-fired power plants and together with bottom ash removed from the bottom of the furnace is in this case jointly known as coal ash. Depending upon the type of coal being used, the specification of Fly Ash varies considerably, but Fly Ash contains substantial amounts of silicon dioxide and calcium oxide (CaO), both being endemic ingredients in many coal-bearing rock strata. We are a reputed Fly Ash Exporter based in India and are supplying Fly Ash different cement, ready mix concrete, steel, refractories and construction industries. The Major Utilization Areas Of Fly Ash : - Manufacture of Portland Pozzolanic Cement & Performance improver in Ordinary Portland cement (OPC). - Part replacement of OPC in cement concrete. - High volume Fly Ash concrete. - Roller Compacted Concrete used for dam & pavement construction. - Manufacture of ash bricks and other building products. - Construction of road embankments, structural fills, low lying area development. - As a soil amender in agriculture and wasteland development. Types of Fly Ash: - According to the type of coal used fly is classified into two types. Anthracite and bituminous coal produces Fly Ash classified as class F. Class C Fly Ash is produced by burning lignite or sub-bituminous coal. Class C Fly Ash has self-cementing properties. - Class F and Class C Fly Ash are products of the combustion of coal in large power plants. Fly Ash is collected in electrostatic precipitators or baghouses, and then transferred to large silos for shipment. When needed, Fly Ash is classified by precise particle size requirements, thus assuring a uniform, quality product. - Class F Fly Ash is available in the largest quantities. Class F is generally low in lime, usually under 15 percent, and contains a greater combination of silica, alumina and iron (greater than 70 percent) than Class C Fly Ash. - Class C Fly Ash normally comes from coals which may produce an ash with higher lime content generally more than 15 percent often as high as 30 percent. Elevated CaO may give Class C unique self-hardening characteristics. Minimum Order Quantity : 1 container
2-Naphthol Basic information Chemical Properties Application Preparation Product Name: 2-Naphthol Synonyms: c.i.37500;c.i.azoiccouplingcomponent1;c.i.developer5;Developer A;Developer AMS;Developer BN;developera;developerams CAS: 135-19-3 MF: C10H8O MW: 144.17 EINECS: 205-182-7 Product Categories: Fluorescent;Naphthalene;pigments;alcohol;MICROCIDIN;Color Former & Related Compounds;Developer;Functional Materials;Intermediates;Aromatic Compounds;Alphabetical;Bioactive Small Molecules;Biochemicals and Reagents;Building Blocks;C9 to C20+;Cell Biology;Chemical Synthesis;Fluorescent Indicators and Probes;Fluorescent Probes;Labels;N;Organic Building Blocks;Oxygen Compounds;Particles and Stains;pH Sensitive Probes and Indicators;Phenols;Dyestuff Intermediates;Aromatics Mol File: 135-19-3.mol 2-Naphthol Chemical Properties Melting point 120-122 C(lit.) Boiling point 285-286 C(lit.) density 1,28 g/cm3 vapor density 4.97 (vs air) vapor pressure 10 mm Hg ( 145.5 C) refractive index 1.5762 (estimate) Fp 153 C storage temp. Refrigerator solubility methanol: soluble1g/10 mL, clear, colorless to light yellow pka 9.51(at 25C) form Powder, Crystals or Granules color White PH Range Non& uorescence (8.5) to blue & uorescence (9.5) Water Solubility 1 g/L (20 C) �»max 226nm, 265nm, 275nm, 286nm, 320nm, 331nm Merck 14,6384 BRN 742134 Stability: Stable. Combustible. Dust may form explosive mixture with air. Incompatible with strong oxidizing agents, phenol. Major Application Display device, semiconductors, photoimaging materials, inks, toner, chalk, security paper, molding materials, tin plating method, rubber, adhesive, leather, detergent, hair dyes, antimitotic drug, anticancer agent, antiinflammatory agent, treatment of acne vulgaris (pimples) and other dermal ailments (rashes, scratches, blemishes, hair loss), disorders InChIKey JWAZRIHNYRIHIV-UHFFFAOYSA-N CAS DataBase Reference 135-19-3(CAS DataBase Reference) NIST Chemistry Reference 2-Naphthalenol(135-19-3) EPA Substance Registry System 2-Naphthalenol (135-19-3) Safety Information Hazard Codes Xn,N Risk Statements 20/22-50 Safety Statements 24/25-61 RIDADR UN 3077 9/PG 3 WGK Germany 2 RTECS QL2975000 F 8 Autoignition Temperature 430 C TSCA Yes HazardClass 9 PackingGroup III HS Code 29071590 Hazardous Substances Data 135-19-3(Hazardous Substances Data) Toxicity LD50 orally in Rabbit: 1960 mg/kg LD50 dermal Rabbit > 10000 mg/kg 2-Naphthol Usage And Synthesis 2-Naphthol Preparation Products And Raw materials
Moisture : 8.5% max. Impurities : 1% max. Size (kernels/100 gr): o 180-200/ o 200-220/ o 220-240/ Broken beans: 3% max. Crop: newest, Origin: Vietnam. Packed in 25/50 kg PP Bag or Jute Bag. 18 MT/ 20'ft. Price: please contact for updated price. Payment & delivery: L/C at sight or T/T 30% in advance. Lead time: 2 weeks/ 1*20'FCL.