GF112V2 made in GFUVE GROUP, is a high precision single phase handheld energy meter accuracy tester in class 0.1, used for testing all kinds of single phase electronic meters error on site. Wide measurement range from 1mA to 200A and 0 to 600V, frequency range 40.000Hz to 70.000Hz, and also can be used to test alternating current electrical parameters - voltage, current, active power, reactive power, apparent power, harmonics, phase angle, power factor, frequency, energy etc. It can display U & I wave form and vector diagram. Small size, light weight, simple and convenient operation. It is an ideal testing equipment for the metrology departments of electricity power companies and electrical service engineers.
Measure normal parameter of power line: Vrms, irms, frequency Active power, reactive power, apparent power Phase angle between voltage and current Power factor Calibrate single phase meter; Measure harmonic of voltage and current; Measure waveform of voltage and current; Measure current transformer¡¡¥s ratio (option); Energy accumulation test; Built-in clock, record testing time exactly; Store, check and transmit the measured data; Connected to pc, reading recorded data and real-time measured data by pc; Alarm when the tested voltage and current over the testing range; Connected to portable printer (option).
GF112 handheld single phase watt-hour meter tester is with human oriented design, hand-held and lightweight. It is suit for electric power departments, measuring and quality examining departments and electric lab to field use. It is capable of testing various types single phase watt-hour meters on site and can also be used for testing alternating current parameters , for example U, I, P, Q, S, F, E etc.
GF112D is a single-phase handheld electronic meter test unit in accuracy class 0.1or 0.2, used for testing single phase electricity meters error on site. Wide measurement range from 1mA to 120A and 0 to 300V, and also can be used to test alternating current parameters - voltage, current, active power, reactive power, apparent power, harmonics, phase angle, power factor, frequency, energy etc.
This product is portable design,used in field to check watt-hour meter error. Accuracy class:0.05. 6.4inch TFT COLOR LCD measured CT variable ratio 0-600V/1MA-12A Check wiring and calculation electricy of compensation.
DDS5558 Single Phase Meter is a kind of new style single phase two wire active energy meter, it adopts micro-electronics technique, and imported large scale integrate circuit, use advanced technique of digital and SMT techniques, etc. It has minimum size, and also a new single phase two wire active energy meter. It has already passed the test of the international authority CE. The meter completely accords with relevant technical requirements of class 1 single phase active energy meter stipulated in international standard IEC 62053-21. It can accurately and directly measure 50Hz or 60Hz active energy consumption from single phase AC electricity net. This meter has white backlight source eight digits LCD monitors shows the active energy power consumption. It has following features: Good reliability, small volume, light weight, specious nice appearance, convenient installation, etc. Features: Bi-directional total active energy measurement 25mm standard DIN rail installation, complying with standard DIN En50022. Single pole width (Modules17.5mm), complying with standard DIN43880. Small modular size, DIN rail mounted. Easy installation to distribution boards, load center, miniature & etc. by identifying where energy is being used. Application: All power parameter measurements; Energy measurement and electrical fire monitor and control; Replacing the three-phase power meter, three-phase electricity transmitter; Transformers, generators, capacitors, and electric motors distributed detection; Medium and low-pressure systems; SCADA, EMS, DCS integrators.
The instrument GF312D1 is a precision 0.05% AC energy meter testing instrument, mainly used to test three phase energy meter error on site, measure all various of AC parameters and CT ratio & phase error, it is also as three phase reference energy meter in the laboratory. Mainly using test single phase or three phase meter error on site. GF312D1 energy meter calibrator is an ideal test tool for the metrological service of electricity power company.
Features: 1. Check the error of active and reactive of watt-hour meter at the same time, and meanwhile check the error of main and secondary meter in the same circuit. 2. Display the electrical constants such as: voltage, current, power, power factor, phase and frequency and etc. 3. Measure ct ratio, wave form display. 4. Measure 2-51 voltage and current harmonics. 5. Judge wrong wiring. 6. Measure the baud rate for multi-function energy meter and meter number reading. ¦ct secondary loading function. 8. Automatically correct the clamp error.
Product description Gf102 single phase energy meter testing set used to test single phase energy meter. Adopt mature signal synthetic and power amplifier technology. High voltage and current output . Widely used in lab and field. Features Meter under testing: 1p2w Testing mode: active power, reactive power Test 3pcs or 2pcs meter synchronously Starting test and creeping test Reference standard and power source integrated, easy to carry. Measuring mechanical meter and electric meter Operating by manual keyboard or pc With shortcut key of normal test point, speed up testing Internal large capacity storage device for mass memory Local checking the testing result Overload, short circuit, open circuit protection With self-checking function Technical data Voltage Test voltage output (phase-neutral) 0v ¡v 264v Power of the voltage output Max. 30va , 15va Resolution 0.01% Accuracy 0.1% , 0.2% Stability 0.02%/120s , 0.05%/120s Distortion factor < 0.3% for linear resistance load Current Test current output 1ma ¡v 120a , 1ma ¡v 60a Power of the current output Max. 100va , 30va Resolution 0.01% Accuracy 0.1% , 0.2% Stability 0.02%/120s Distortion factor < 0.3% for linear resistance load Phase angle Range 0 -- 360¢x Resolution 0.1¢x Accuracy 0.2¢x Frequency Range 45hz ¡v 65hz Resolution 0.005hz Pulse output High frequency output(ch) 1.666¡ñ105 hz Low frequency output(cl) 5¡ñ10-5¡ñch Pulse input Input channel 3 Input frequency Max. 20hz Other Voltage supply 220v¡ó10% 50/60hz¡ó2hz Ambient temperature -10¢xc -- +40¢xc Relative humidity 35% -- 85% Dimensions (w¡ñd¡ñh) (mm) 445¡ñ440¡ñ180 , 410¡ñ220¡ñ150 Weight (kg) 18 , 9.5 Dimensions (w¡ñd¡ñh) (mm) 445¡ñ440¡ñ180 , 410¡ñ220¡ñ150 Weight (kg) 18 , 9.5
INTRODUCTION: The instrument is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure all various of AC parameters. FEATURES Three phase active or reactive electricity energy meter. Calibrate three phase, single phase, and active or reactive meter error. Measure U(voltage) of three phase or single phase. Measure I(current) of three phase or single phase. Measure active power of three phase or single phase. Measure reactive power of three phase or single phase. Measure apparent power of three phase or single phase. Measure power factor of three phase or single phase. Measure phase angle between voltage and current. Measure frequency of power line. Display vector diagram. Display waveform of U and I. Analyze and display content of harmonic of U and I. Measure 2-64 harmonic of U, I. Store and display measured data. Optional 5A, 20A, 100A, 500A, 1000A, 2000A, 3000A current clamp. Measure CT variable ratio. Measure the ratio or lag-angle of low-voltage transformer. Adopt 32 bit ARM processor, multi-channel 16 bit precision A/D convertor, high resolution TFT color LCD. Inner equipped with 0.01% wide-range current transformer and can be equipped with various type current clamps, wide range of measurement and high veracity. Low consumption circuit design, high energy Lithium battery supply, intellectual power management software, which enables the instrument continuously working up to 10 hours.
Type: dds-1y-18m Current: 5(32)a, 5(40)a, 5(45)a, 5(50)a Voltage: 110v; 220v; 230v; 240v Accuracy: 1.0; 2.0 Constant: 1000imp/kwh Frequency: 50/60hz Connection mode: direct type;external ct type Display mode: counter 5+1 = 99999.9kwh Power consumption: n0.4w; n8va Start current: 0.004ib Din-rail standard: so43864 Executive standard: gb/t17215-2002; iec61036 120pcs/ctn. Carton size:50.2*40.5*19.5
Single Phase DIN-Rail Energy Meter (DDS-1Y-L) Executive Standard: IEC62052-11 2003; IEC62053-21 2003 and IEC62056-21(IEC1107) DIN-rail standard: "SO"43864. Function and characteristic: Single measurement(optional RS485 or RS485 Modbus) High accuracy of measure, convenient installation; Logical design of Anti-creep. Technical data: Rated voltage: 110V, 120V, 220V, 230V Rated Current: 1.5(6)A, 5(60)A, 10(100)A Frequency: 50-60Hz Connection mode: CT type; Direct type Display mode: LCD 5+2 = 99999.99kWh Accuracy Class: 1.0 Power consumption: 1W (when 220V 20A) Start current: 0.004Ib Constant: 12800 imp/kWh; 800/1600/3200/6400 imp/kWh Standard work temperature: -20-45 degree Climate work temperature: -30-55 degree Relative humidity: 85%. Size: 100*76*65 mm.
Single phase long life electronic energy meter Major technical data: Name of product: single phase long life electronic energy meters Type: dds 318 Accuracy class: 1.0 Power consumption :< 6va Rated voltage: 220v 240v Rated current: 2.5(10) a 5(30) a 10(50) a Application: By adopting advanced pcb and smt technology, dds318 single phase long life electronic energy meter is used to measure the energy of 50hz single phase a.C power. Salient feature: 1.High accuracy:1.0class 2.High overload capacity: 6 times of overload. 3.High reliability: long operating life. 4.Low power consumption, small size, light weight, tamper proof and easy to install. 5.Smt and re-flow soldering technology is adopted. Meter has strong capability for disturbance. Emc can comply with requirement of iec61036-2000. 6.With impulse output interface for direct calibration of the meterf+s accuracy, or for measurement of the impulse input in case of mass-metering. 7.Power indicator to test the optical power end and calibrate the accuracy of the meter. 8.Electric power line carrier system and telephone remote-metering system can be supplied for userf+s option. 9.It can be changed into single phase plc electronic energy meter
Features: 1) high accuracy, reliability, overload capability 2) low power consumption 3) smt technology and re-flow soldering technology Major technical data: 1) accuracy class: 1.0 2) power consumption: less than 4va 3) rated voltage: 200v 4) rate current: 2.5(10)a, 5(25)a, 10(40)a Main functions: 1) measurement of single-phase 50hz active power and power consumed 2) set up maximum load, overload warning and power off 3) warning of remained energy and remind user for payment 4) re-read power consumed, remained energy and number of prepayments for power 5) power off when no energy in the meter 6) parameter transferring through ic card Salient features: 1) high accuracy: 1.0 class 2) high overload: 6 times of overload 3) high reliability: long operating life 4) low power consumption, tamper-proof, light weight, small size and easy to install 5) register displays consumed power, and led displays status of consumed power 6) smt technology and re-flow soldering technology are adopted. Meter has strong Capability for disturbance. Emc can comply with requirement of iec 61036-2000 High overload capacity, high reliability of relay Single-phase and 3-phase pre-payment electronic energy meters can share one set Light weight, small size, easy to install Of prepayment control system
DESCRIPTION The DDSY1088 single phase two wire postpaid meter is made of high quality optimized long life components and designed in advanced SMT technique with good performances on reliability, accuracy and load ranges.DDSY1088 provides metering solution benefiting both consumers and power utilities. It complies with the applicable standards of IEC1036, IEC62052-11, IEC62053-21. FEATURES 1. High accuracy measurement with LCD display,5 integers. 2. Wide operating voltage range 0.8Un ~ 1.15Un. 3. Long time precisely works without calibration and limit error linear maintains flat during heavy loading from start to end. 4. With active impulse LED indicator and reverse energy LED indicator 5. With cover of terminal block made by transparent material. 6. Measures active energy,reactive energy and reverse always add to positive. 7. Meter base and cover ultrasonic sealed 8. The communication between meter and CIU is PLC
DESCRIPTION The single phase two wire electronic meter is made of high quality optimized long life components and designed in advanced SMT technique with good performances on reliability, accuracy and load ranges. featured with source-load missing neutral anti-tamper function, and provides metering solution benefiting both consumers and power utilities. It complies with the applicable standards of IEC1036, IEC62052-11, IEC62053-21. FEATURES 1. LCD display with backlight function even if power failure. 2.Wide operating voltage range0.7Un ~ 1.15Un, withstand 1 hour limit operating voltage up to 380V. 3.The meter can works under harsh environment conditions of kind of variations by high accuracy in a long time 4.without calibration, and its limit error linear maintains flat even during heavy loading status from start to end. 5.Useful infrared communication for meter reading and setting. 6.With active impulse LED indicator and impulse test output. Anti-Tamper function. 7.Measures voltage and current with LCD display. 8.Maximum demand.
DESCRIPTION Hexcell single-phase PLC meter based on digital media information exchange medium, it features include active measurement, high precision clock, load switch control, moreover can also reading data from the PLC, the near infrared, RS485 and set parameters FUNCTIONS 1.Rmeasure active power forward and reverse respectively, measuring the total active power (forward and reverse) 2.Event log including: power, open front cover, open terminal cover, reverse, magnetic field, the unbalanced load, over voltage, low voltage, programming records, time corrected record and remote pull switch, etc. 3.Tariffs: 4 tariffs, Monday to Sunday 7 ordinary day time, 16 holiday period, 16 special holiday time, can be divided into eight period one day. 4.Contains hours freezing (24 hours), froze1.n (62 days) and freeze power in previous 12 months 5.Remote switching function 6.Load profile: load profile for 30 minuters, frozen data (time + live wire power + null wire power load profile)
Description The ddsy1088 single phase keypad energy meter measures total active energy.It is STS certified. and complies with the standards of IEC62052-11, IEC62053-21, IEC62055-41 &IEC62056-21.BS standard complied. It can be inserted the plug-in communication module to achive the AMR/AMI solution.And with built-in relay,it can be remote control. Function 1.Easily configurable Prepaid & Postpaid mode by token 2. Anti-tamper 3. Load profile 4. Exchangeable, optional communication module:GPRS/3/4G/PLC/GSM/Ethernet 5.Real time measures voltage, current, frequency, active power, etc 6.Open Protocol: DLMS/COSEM 7.Programable multi-tarrif
Snt 1100 single phase meter test bench is widely used in power utilities,¡émeter manufacturer,¡émeasurement/quality test lab and other enterprises to test single phase energy meter.