GE Discovery 670 NM SPECT CT Year : 2012 Tube Model and Year : Performix / 22/11/2022 Total patient exams: 268 ConnectPro, SmartScore Pro / Volume viewer / Smart Prep / Helical tilt / Auto MA / Patient 16 slice / smart speed / power 440 / 90kVa / Copy composer / Direct â?? MPR , Data export / Noise reduction Filter / EKG Viewer / Enhanced Recon ASiR, NM subsystem has LEHR collimators Evolution for Bone Planar, Bone SPECT, Cardiac, Evolution Toolkit, Q.Metrix, Axial head holder
Year:2013 Tube Model: Performix HD+ Tube scan second : 186,625. Tube Changed Year:: 03/ 2022.
Year 2011 Tube Replaced : 03/ 2021 Tube Usage: 675470.5 Scan Seconds:192817861.5 mA Seconds
Year: 2015 Tube Year: 2021 Tube count: 155 590 432 mAs Tube model: Performix 40 MX200 CT 2 Detector size: 9*6 Air cooling Software version console:Pet-coreload.87H40-P2-SS64-G-GTLNI 9*6-lyso
GE Brivo385 Year of Manufacture: 2014 Tube Changed on 29th January, 2023 Only 76,006.6 scan sec. as of 20th June, 2024.
Dom: 2004 excellent condition. In clinical use. Will be available at the end of august. Crated
4 octane, console S/N: 273425CN9, gantry slices:3, 728, 938 March 2010 tube, mas 30.849.820.5, gantry covers, S/W version 2.4.2_h2.4m5, 48cm phantom, 35cm phantom, phantom holder, cradle extender, axil hh, coronal hh, mod’s, mod drive, cables, manuals, monitors Options:reformat, auto ma, power 440, thin twin helical, helical tilt, recon plus, navigator, 3d, smart speed, smart prep.
Easy to handle Standard Lot Size
2012 Tue Changed Year: 2019 Tube Model: Performix 40 Tube scan seconds 190,126.100 sec
Year of Manufacture: 2008 Tube changed in 2021 and used for 2.5 years. Tube: Less than 70,000 scan sec. No indication because of Non-Working Console
New & Refurbished Systems Available!!! We Offer New, Used, And Refurbished CT Scanners. We Also Offer Installation And Inspection Services. Siemens, Ge, Hitachi, Toshiba, Philips And Many More!!!
GE Lightspeed VCT 64-Slice CT Scanner Year: 2006 Tube Model: Performix VCT+ Tube year : 03/2022 Tube Scan Seconds: 451602.8
GE Brightspeed 16 Slice CT Scanner Year: 09/2010 Tube Model: Solarix 350 Tube Year: 06/2023 Total Tube mas: 8203566 Total tube scan second: 46578.3
2010 Tube Year: 5/2022 Tube Model: Solarix 350 69,965.300 Scan Seconds With Injector, Lead Glass and Printer
2008 toshiba aquilion 16 slice 2008 Available jan/feb Currently in clinical use Crated
Toshiba Activion CT Scanner Year: 2010 Tube 2024 Slice Time: 740950.5 Exp Count: 500049 Deinstallation In End Of July 2024
GE BrightSpeed 16 Pre-owned CT Scan System with Standard Accessories Without Tube (Presently using a Tube under Leasing) Non-working Tube will be supplied if desired. As is in Working Condition Year of Manufacture: May, 2012 Deinstallation: Scheduled on 26th July, 2024
SIEMENS SOMATOM Definition AS Year:2010 Tube year: 2019 Tube Model: STRATON MX Tube scan seconds 312,070 Software version : VA48A with Injector , Printe, lead glass
HITACHI Supria 16 Year : 2014 Tube Size: 2.0MHU Tube Model: Ulm 5TA 01T Tube Year: 04/ 2014 Tube count : 70,000