"Operating voltage: AC110V or 220V Gas species: Natural gas or LPG Sensor: Semiconductor Wireless frequency: 315Mhz or 433Mhz Chip: 2262/1572 Drivable accessaries: Solenoid valve Alarm output: Sound & LED flash alarm&RF signal > adopted SCM from USA to ensure the stability, > intelligent circuit design, break-through anti-oil technology; "
"Semiconductor sensor Operating voltage: 85-265V AC; Alarm output: Sound& LED Flash alarm; Alarm level: 10% ±5% LEL. adopted SCM from USA to ensure the stability, Dimension: 118.5*82*43mm . Execute criterion:GB15322;EN50194;UL1484 Can make 9V chargable back up battery "
"Semiconductor sensor Operating voltage: 85-265V AC; Alarm output: Sound& LED Flash alarm; Alarm level: 10% ±5% LEL. MCU processing adopted,SMT adopted,good stability Malfunction auto-check indicator Dimension: 118.5*82*43mm . Execute criterion:GB15322;EN50194;UL1484 Drivable accessaries: electromagnetic valve and exhaust fan; Can make 9V chargable back up battery "
"Operating voltage: AC110V or 220V Gas species: Natural gas or LPG Sensor: Semiconductor Wireless frequency: 315Mhz or 433Mhz Chip: 2262/1572 Drivable accessaries: Solenoid valve Alarm output: Sound & LED flash alarm&RF signal > adopted SCM from USA to ensure the stability, > intelligent circuit design, break-through anti-oil technology; "
12V D.Cauto-test for malfunctionAlarm Output: sound & flash alarm&relay output; ceiling mounted
"AV voltage: AC 90V-240V 50-60Hz Battery voltage: 9V rechargeable battery (optional) Working temperature: 0°C-50°C Warm-up time: about 180S Environment: 10%-95% Sound level: 85dB / m Alarm density: 2500PPM (±1500PPM) Size: 112 Ã? 73 Ã? 42MM"
"Semiconductor sensor Operating voltage: 85-265V AC; Alarm output: Sound& LED Flash alarm; Alarm level: 10% ±5% LEL. adopted SCM from USA to ensure the stability, Dimension: 118.5*82*43mm . Execute criterion:GB15322;EN50194;UL1484 Can make 9V chargable back up battery "
AK-200FC/L Product Description: 1. Model: AK-200FC/L 2. Back-up battery: Rechargeable battery, ordinary battery 3. working environment: Humidity: ¿Q97%RH Temperature: 0íµ-60íµ 4. Dimensions: 163mm*87mm*40mm 5. Working voltage: 220VAC /110VAC, 12VDC-20VDC 6. Additional function: can work with solenoid valve or manipulator or exhaust fan (optional) 7. Networking: wired networking (NO, NC) 8. Wireless networking mode: 315MHZ/433MHZ (2262 OR 1527) 9. Alarm concentration: coal gas: 0.1%~0.5% natural gas: 0.1%~1% LPG: 0.1%~0.5% 10. Automatic error-detecting function (The red and green lights shine alternatively). 100pcs/CTN.
Main features: Auto reset after alarm Mcu process Sensor with high stability Auto check and indication for malfunction Detecting natural gas and lpg Smt adopted Supports exhaust fan Technology parameter: Operating voltage: ac 220v or dc 9-16v Standby current: less than 90ma or less than 30ma (low power consumption) Alarm current: less than 100ma or less than 40ma (low power consumption) Rated power: less than 3w (ac 220v) Operating temp.: -10 to +50 degrees Working humidity: less than 95%rh Alarm mode: network output / sound & flash alarm / rf Alarm volume: more than 85db/m Alarm density: 10%lel Alarm output: relay output (n.C.And n.O. Optional) / rf signal Dimension: 70l*40w*110hmm Colour box or carton packing
Wireless gas - leakage detector 1. Independent mode: it works as wireless auto gas leakage alarm detector. 2. Compatible mode: it works with our burglar alarm system. 3. Widely used for kitchen to make safety. 4. Self-detector and automatically give an alarm warning to users. When it works with our burglar alarm, with led indicated, it sends a wireless signal to alarm host if detecting density with time reaches the limit figure required as below and then it alarms and the alarm host auto-dials the pre-setting telephone or mobile phone 5. It is strictly compliance with quality system, it can be effective to prevent fire by flammable gas, such as coal Color box in carton
"AV voltage: AC 90V-240V 50-60Hz Battery voltage: 9V rechargeable battery (optional) Working temperature: 0°C-50°C Warm-up time: about 180S Environmental humility: 10%-95% Sound level: 85dB / m Alarm density: 2500PPM (±1500PPM) Alarm: vocals and LCD Size: 112 Ã? 73 Ã? 42MM"
"AV voltage: AC 90V-240V 50-60Hz Battery voltage: 9V rechargeable battery (optional) Working temperature: 0°C-50°C Warm-up time: about 180S Environmental humility: 10%-95% Sound level: 85dB / m Alarm density: 2500PPM (±1500PPM) Alarm: vocals and LCD Size: 112 Ã? 73 Ã? 42MM"
"12-24V; Sound & LED & Relay NO or NC output Drivable accessaries: electromagnetic valve and exhaust fan;"
"Operating voltage:DC12V-24V Gas species: Natural gas or LPG Sensor: Semiconductor Drivable accessaries: Solenoid valve Alarm output: Sound & LED flash alarm, Relay output > adopted SCM from USA to ensure the stability, > intelligent circuit design, break-through anti-oil technology; "
Wireless gas leakage alarm Model:CVC-Q02 Features 1. Automatic Reset 2. Microprocessor control 3. High reliability sensor 4.automatic fault detection indication 5.detection of natural gas, liquefied petroleum gas 6.SMT process, strong stability Specifications 1.Operating voltage: 220VAC or 110VAC, 12DC-20DC 2.Basic Alarm concentration: 3.Combustible gas: Gas 0.1% ~ 0.5%, LPG0.1% ~ 0.5%, 4.Natural gas: 0.1% to 1% 5.Gas body response time: ¡Ü 30S 6.Gas body recovery time: ¡Ü 30S 7.Select features: 8.Exhaust fan interaction, together manipulator, solenoid valve 9.Wired networking: (NO, NC) 10.Wireless networking: 315MHZ/433MHZ (2262 Coded excitation) and the rolling code. Size:111 * 71 * 43.4mm Carton box.
Gas leakage sensor Gas leakage detector alarm Gas alarm Name: stand-alone gas leakage detector Model: gl-01 The stand-alone gas leakage detector is an input device designed for natural gas, LPG detection. It can use independently. Upon detection of natural gas and LPG, the gl-01 automatically generates sound & flash alarm. The unit is RF and EMI immunity to interferences produced by radio device. Applications: for indoor use. Gift box.
"AV voltage: AC 90V-240V 50-60Hz Battery voltage: 9V rechargeable battery (optional) Working temperature: 0°C-50°C Warm-up time: about 180S Ambient humidity: 10%-95% Sound level: 85dB / m Alarm concentration display Carbon monoxide gas: 100PPM~999MM (±50PPM) Combustible gas: 0.25%~2% LEL (2,5500PPM~20,000PPM±1,500PPM) Alarm: vocal alert and siren alarm"
Alarm peak query function Alarm point setting function Super-smart voice function 4 concentration unit conversion Suitable gas: natural gas Concentration alarm: 1-25%lel £¨500-12500ppm£© Alarm set: 05-99kppm or 10-198%lel Input power: 37v 2600mah lithium battery Static current: ¡ü200ma Alarm current: ¡ü500ma Response time: £¼30 second Alarm sound: £¾80 decibel (from 1m) Sensor:japanese electrochemistry sensor Agent query function Alarm peak query function Smart voice alarm and digital display Alarm point settings Concentration unit conversion Black
"AV voltage: AC 90V-240V 50-60Hz Battery voltage: 9V rechargeable battery (optional) Working temperature: 0°C-50°C Warm-up time: about 180S Ambient humidity: 10%-95% Sound level: 85dB / m Alarm concentration display Carbon monoxide gas: 100PPM~999MM (±50PPM) Combustible gas: 0.25%~2% LEL (2,5500PPM~20,000PPM±1,500PPM) Alarm: vocal alert and siren alarm"
Kq500 fixed gas detector is a kind of wall-mounted type detector that can be used continuously in operation environment to detect the concentration of combustion gas, oxygen, and toxic gas. The detector detects gas concentration in natural diffusion way. Kq500 intelligent gas detector transforms the gas density in the operating site into standard electric current signal(4-20ma). Main features: L it can detect more kinds of gas. High precision L fixed explosion-proof shell; it¡¯s safe and reliable L standard 4-20ma electric current output, compatible with existing alarm control unit or dsc (distributed control system). L imported sensor, high sensitivity, rapid response, stable and reliable Operation is simple; easy installation and maintenance Box