epoxy Paulownia glass powder mica foil 5440-1 is provided by Dongfang Yoyik. Our company mainly offer spare parts of power unit, including thousands of types and models, for power plants, steel mills, cement mills, chemical plants and shipyards. Our products can be applied various systems from EHC, TSI, MEH, DCS, to excitation system and hydrogen oil water system. epoxy Paulownia glass powder mica foil 5440-1 STEAM SEAL RING X300E-177100ARN LVDT HP BY PASS 2000TD Generator Cover sealant injector KH-35 Gridã?? JS109 RTV brushing adhesive HDJ-138 2ï¼?1 Tachometric Sensor QBJ-CS-2 polyester varnished glass cloth tape 2410 high pressure motor cleaner DQ-50 generator sealing grease T25-75 sealant DE82-2 CARBON BRUSH YHJ204 32MM X 18MM X 45MM Precision Transient Speed Monitor DF9011 insulating cover plate 4Q6672 Tube Male Screw Connector Q/D9111G-77 (87) epoxy Paulownia glass powder mica foil 5440-1 wear-resistant insulating steel ceramic tube generator red insulating insulating varnish 188 TRANSFORMER DET250A sealant WH-53351JG Z1c001289 Z1c001281P003 slot Sealant HEC892 end cap Hydrogen sealing Sealant T20-75 epoxy semi-conductive glass fiber plate 9332 0.25*25.7*1270 Seal ring for stem sleeve assembly of IPCV D600B-265531A002 COACH SPRING D00.160.002 Dual Channel RTD WZPM2-001, DZ3.5.1-1995 adhesive Y137 Locking Block D185A-241000A007 RTV dipping varnish 793 epoxy Paulownia glass powder mica foil 5440-1 ã??2019-10-31-DFJerryã??
1. Calcium Chloride powder 74% cacl2 92% cacl2 94% 2. Magnesium Chloride flake 3. Sodium Meta Bisulphite (food grade 94 96%) 4. Silica Quartz ore purity: 98% available, silica quartz powder/purity: 99.9% available, silica lumps purity: 99% available 5. Garbage Bags: disposable plastic hand glove, garbage bags on roll, oxo-biodegradable bag, bio hazard bags, compostable bags, grocery bags , shopping bags, shopping bags (loop handle), bakery and snacks bag, industrial liner bag, self adhesive bags, bouffant cap, aluminum foil, vegetable bag on rolls, pp printed bags, biodegradable bag, ld & hm industrial liner bags, pp self adhesive tape bags 22 bopp bags 23 laminated pouch 6. Red Onion as per your required size. 7. Antigen kit: a) who certified kit b) ce certified kit 8. carbon black 9. sodium acetate anhydrous 99% sodium acetate trihydrate crystal 99%10.pet preform & fiber, bottle, flakes, 11. capsicum or bell pepper, ready to eat foods, ready green paste like ginger, garlic 12. Pe.We also do logistic work for cif and we have 3rd party facilities like sgs on client chargeable base.
The manufacture of both granulated and powdered garlic is the same, except for the grinding or powdering process. Granulated garlic is coarse while garlic powder is ground extra fine. Whole cloves of garlic are peeled, cleaned and then sent into a machine that slices and chops them into smaller sections. The sections are dried in slow ovens for three to four hours. When the garlic has cooled it is ground to the desired consistency, be it granulated or powdered. The finished products are put through sifters to separate any debris or undesirable pieces. Both are packaged in air-tight containers and stored in a cool, dry place. Granulated and powdered garlic are used to season and enhance the flavor of many foods. Often it is an appropriate substitute when fresh garlic is called for in a recipe. Powdered garlic dissolves almost instantly when incorporated into any dish, hot or cold. Granulated garlic takes a few minutes to become incorporated and release its flavor. We can offer Garlic Granules in 0.5mm to 1.0mm, 40/60 mesh, 26/40 mesh - 20 FCL: 10 Mt (Flakes/Cloves), 14-15 Mt (Minced/Granules/Powder) - 40 FCL H/C: 20 Mt (Flakes/Cloves), 25-30 Mt (Minced/Granules/Powder) Product Packing - 12.5/13/14 Kg Paper Bag inside 1 Poly Bag - 20/25 Kg Cartoon inside 1/2 Poly Bag - 20/25 Kg Cartoon inside 1/2 Aluminium Foil Bag Our range includes: - Dehydrated Garlic Flakes/Cloves (5-10mm) - Dehydrated Garlic Minced (1-3mm, 3-5mm) - Dehydrated Garlic Granules (G1, G2, G3) - Dehydrated Garlic Powder (80-100 mesh) -
ProName: Acetone oxime ,Acetoxime CasNo: 127-06-0 Molecular Formula: C3H7NO Appearance: White crystal ProductionCapacity: 1-100 Metric Ton/Month Grade: Industrial Grade Specifications: index value appearance white crystalline powder or flakes Assay 99.0% residue on ignition 0.01% Boiling point 135 c at 1,013 hpa Moisture 0.25% Uses: It is used as raw material for medicine, pesticides, dyes and organosilane coupling agents. It is also useful in the determination of nickel and cobalt. Acetone oxime is an excellent corrosion inhibitor (deoxidant) with lower toxicity and greater stability compared to hydrazine. Package: 25kg carton drum or 1kg foil bag or by request of clients Storage: Store in dry, dark and ventilated place Transportation: by sea or by air
Commodity:Avobenzone CAS No. 70356-09-1 Molecular Formula C20H22O3 Molecular Weigh 310.39 EINEC No. 274-581-6 Specification Quality standard: USP36 Appearance Off-white powder Assay 95.0-105.0% Melting range 81.0~86.0 Impurities Any individual impurity: 3.0% The sum of all of the impurities: 4.5% Loss on drying 0.5% Packaging and storage: 1kg/aluminum foil bag. 25kg/barrel, pharmaceutical packaging barrel. Sealed, stored in dark, with a shelf life of 2 years. Reference dosage: The hygiene standards for cosmetics stipulate that the maximum amount added shall not exceed 5%, and the general dosage is 1-4%. Usage: Sunscreen agent-1789 is the most effective fat soluble UVA filter and is a safe and effective UVA sunscreen approved by the US FDA for sale on the counter. It can effectively block UVA, thereby increasing the SPF value of sunscreen products. It can improve the efficacy of sunscreen products when used in combination with UVB filters, and BL-200 has the best effect when used in combination with octyl methoxycinnamate. BL-200 can increase its stability in the product. It has an extremely effective protective and repairing effect on human skin. Application: This product is soluble in oil and can be formulated into a cream using the usual method. However, the product turns red when it encounters metal ions, so other components such as formula water should not introduce metal ions. The equipment should be made of pure stainless steel, and an appropriate amount of EDTA-2Na should be added to the formula water phase to chelate with metal ions.
1.Name: Sodium nitrate Chemical formula: NaNO3 Formula weght:84.99 2.Property: (1) ordinary sodium nitrate: white little crystals or light yellow (2) dry powder sodium nitrate: non-caking, showing loose status. Density:2.257. It is liable to deliquesce, dissolved in water, soluble in liquid ammonia, slightly soluble in ethanol and glycerin, Melting Point:308. While being heated up to about 380 it will decompose and release oxygen and turn into sodium nitrite,as the heating goes on, it will decompose into oxygen, nitrogen and nitrogen oxide. It has strong oxidability and can cause combustion explosion if being mixed with organic substance, sulfur, sodium nitrate etc. 3. Usage:Â it has been wildly used in the glass industry, dye, dynamite, metallurgy, machinery, ceramic etc. 4. Specification: (Technical Standards:GB/T4553-2002) Item Unit High G. First G. Qualified G. Dry powder G. Assay % 99.7 99.3 98.5 99.3 Sodium nitrite % 0.01 0.02 0.15 0.02 Chlorides % 0.25 0.30 -- 0.25 Water insolubles % 0.03 0.06 -- 0.03 Moisture % 1.0 1.5 2.00 0.2 Carbonates % 0.05 0.10 -- 0.1 Iron % 0.005 -- -- 0.005 Loose degree -- -- -- 95 5.Package: net 25kg/50kg net each in plasic woven inner plasic bag,or 500kg net each in flexible container.
Refractory bricks, high alumina bricks, acid proof bricks, tiles and castables, all mortars and fire clay, low cement castables, insulating castables, conventional dense refractory bricks, insulation bricks, cold face, hot face insulation bricks, hot face insulation bricks, acid resistant bricks/components, membranes, acid resistant cement, construction chemicals, class 1 ar tiles and bricks 38mm and 75mm, 4457 vitrified ar tiles with 0% water absorption, 20mm & 25m, primer, mastics, pot. silicate cement, coerce cement, furnace based cement, crushed refractory boiler bed material, acid resistant tiles, acid resistant brick fireclay type, acid resistant brick red shale type, bitumen primer, epoxy resin & hardner, furan powder and syrup solution,.
mica foil 5440-1 is an exclusive product for power units offered by Yoyik. Dongfang Yoyik Engineering Co., Ltd mainly provides hydraulic components, spare parts of power units, mechanical parts processing and so on. We have spare parts, components, replacements for generators, boiler, turbines and hydroturbines. aluminum bronze slot wedge orging-blank 3Q6192 mica foil 5440-1 dryer DECJ1213 room temp curing solvent-free varnish 841A+841B insulating tube (Outside) 4QG1262 Tongma Epoxy Glass Powder Mica Tape 5440-1H HT grease gunsealing gasket TN-9001 26000*1016*1.6mm High Temperature Sealant COPALTITE CEMENT 5 Oz. COPALTITE Sealant sealant HDJ-750-2 end cap Sealant T20-75 insulation gasket 40*22*5 Corrugated plate Sealant Loctite 587 motor carbon brush NCC634 102*38.1*25.4mm LR anti-corona varnish T134 mica foil 5440-1 oil sealing cover glass cloth tube 3640 Ï?21/Ï?25*84 epoxy polyamide resin 6101 generator end cap sealing grease WH-53351JG sealant HDJ892 room temp curing HR anti-corona varnish J0701 steam turbine generator sealing grease 53351JG insulating washer 4B150 corrugated plate 219 fiberglass strip Ï?3 sealant injector 3Q3358-9 glass cloth tube 3640 Φ21/Φ25*84 epoxy Polyester air-drying clear varnish 9120 heat-resistance varnish 133756 insulating heat dry clear varnish H31-3 steam turbine generator Sealant T20-75 mica foil 5440-1 ã??2019-11-29-DFJerryã??
Magnesia Bricks Description Magnesia Bricks are alkaline refractory materials. These products have over 90% magnesium oxide content and adopt periclase as the principal crystalline phase. Magnesia Bricks can be divided into two categories of Burnt Magnesia Bricks and Chemical Bonded Magnesite Brick. They have excellent performance of superior high temperature mechanical strength and volume stability. Magnesia Bricks can service in the high temperature of 1750.. They are ideal products for glass furnace application. Magnesia Bricks Features: It is a kind of alkaline refractory product with periclase as main phase magnesite-alumina spinel clinker as basic material. the product has such characteristics as good temperature vibration, good strength and volume stability in high temperature. Magnesia Bricks Application Basic open-hearth furnace for steelmaking Electric furnace bottom and wall Permanent lining of oxygen converter Non-ferrous metal metallurgy furnace Hyperthermia tunnel kiln Lining of rotary cement kiln Heating furnace bottom and wall Regenerative chamber of glass furnace Magnesia Bricks Properties High Refractoriness Good alkaline slag erosion resistance High apparent initial softening temperature Good thermal conductivity High thermal expansion Magnesia Bricks Manufacturing Process Burnt Magnesia Bricks are manufactured with magnesite clinker as the raw material and fired in the high temperature of 1550~1600 after smashing, burdening, mulling and molding. High-purity products can be fired in the temperature that over 1750. Chemical bonded magnesite brick is produced with certain chemical bonding through mixing, molding and drying.
* PHOSCAST Phoscast : Phosphate Bonded Castables * PURPOSE customers using FBC boilers (Particularly underbed feed FBC boilers) for the protection of inbed coils against erosion potential by applying highly abrasive resistant refractory on inbed coils above fuel feed system. BACKGROUND * Two of such actions are providing special alloy studs on inbed coils and applying highly abrasive resistant refractory on the outer bottom loops of inbed Coils which are above the fuel feed nozzles. * GANESHAS has taken number of approaches to identify the key factors affecting erosion rates with an objective to enhance the life of inbed tubes as well as implementing the corrective action to reduce the erosion rates. Phosphate coatings are often used to protect steel parts against rusting and other types of corrosion * Erosion of inbed coils in fluid bed combustor is unavoidable phenomenon however the rate of metal wastage and thus the life of tubes depends on various factors like ash & fuel properties, design of Combustor / feeding system, flue gas velocities operating conditions etc. It has been also observed that maximum erosion prone inbed coils are those which come above fuel feed nozzles and an area of approximately 1 to 1.5 mts around fuel feed systems are badly affected. APPLICATION Phoscast-90 XR can be applied by ramming with wooden mallet having adequately large head @" dia x 5" length x 10â?? Jong handle). The desired lining or repair thickness is built up in several courses while ramming the mass to uniform thickness. Phoscast refractory should never be trawled to obtain smooth surface; ramming only should finish surface. Any excess mass is to be sliced off with trowel edge and then finished by ramming again for bed coil. Tube application of AFBC boiler, the material pasty mass should be finger pressed into the studs of the tube with maximum force. Finish should be given by pressing the hand palm against material applied, using surgical type thin rubber hand gloves.
Ramming mass is commonly used in metallurgy, building materials, non-ferrous metal smelting, chemical, machinery and other manufacturing industries. Ramming mass is widely used in non-core intermediate frequency furnace and core induction furnace. As an intermediate frequency furnace ramming material, refractory ramming is applied to melt gray cast iron, nodular cast iron, malleable cast iron, vermicular cast iron, and cast alloy steel; to melt carbon steel, alloy steel, high manganese steel, tool steel, heat resistant steel, stainless steel, molten aluminum and its alloys; to melt red copper, brass, white brass, bronze and its alloys, etc. Induction furnaces are used for melting cast iron, mild steel and various alloy steels in foundries and making of steel in mini steel plants using sponge iron The refined high silicon, low iron quartz sand and quartz powder are selected and the fused quartz sand is added as the refractory material., with no slag, no crack, damp proof, convenience of repair, and the corrosion resistance, thus greatly improving the furnace service life span and the economic benefit.. Silica ramming mass can safely be used up to an operating temperature of 1600 deg C. Since it expands very little, it is superior to both alumina and magnesia refractories to resist thermal shocks Acid ramming material is the premixed ramming mass of the lining material. The acid ramming mass is used to smelt a series of metal materials such as ordinary steel and carbon steel. The lining practice best suited to a particular furnace depends upon the capacity and design of the furnace, operation practice adopted during making of a heat, and furnace output.
METHOD OF APPICATION: * Mastic compound application consist of two coats of. Primer ,Primer and followed by Mastic compound in recommended thickness, ranging from min. 12mm to 25mm in one or two layers to achieve desired thickness without any pin hole and crack. 1). Surface preparation and application of Primer: Refer application method of Primer. 2). After doing necessary surface preparation and application of primer coating, area to be installed with Mastic compound should be divided in to equal no. bays. To maintain even thickness required, place wooden or aluminum batten. Mastic compound is then broken in small pieces and put it in heating pan. While heating, keep material moving to avoid burning. It is heated until it comes in a uniform consistency and then applied on the surface and works it with wooden float, to achieve uniform thickness and smooth surface free from any pinholes. CHEMICAL RESISTANCE PROPERTIES: * Mastic compound has good resistance to weak, diluted acids, alkalis salts etc. It is not recommended to use against strong acids, oxidizing acid solvents, oil and fats STORAGE & PACKING: * Keep Mastic compound away from direct sunlight, heat solvents etc. Under this condition, its shelf life is unlimited. It is supplied in cake form and approx. wt. is 10 kgs. HEALTH & SAFETY: * Handle melted Mastic compound compound very carefully . Avoid contact with skin. It is advisable to wear protective wears at the time of use of Mastic compound and all other our products. This information, given in good faith, is based on results gained from experience and tests. However, all recommendations or suggestions are made without guarantee since the conditions of use are beyond our control.
APPLICATION OF SK-HB K-SILICATE MORTAR : * K-SILICATE is used for jointing Acid Resisting brick in construction of vessels in suited for construction of fume chambers and stacks handling hot, dry Acid fumes and vapors. It is also used for jointing chemical resisting stoneware pipes. K-SILICATE cement is good bedding material for Acid â?? Resisting bricks and tiles. The concrete surface needed protection should be dryed, clean and rough. The bricks or tiles will be set with K-SILICATE cement over concrete surface applied with a suitable an impermeable interliner. When Bedding and Jointing Materials are the same. On the treated surface bricks or tiles are bedded to a thickness of about 6 mm and tamp gently with a wooden piece till the paste squeezes out of joints. The paste that is squeezed out of the joint should be removed by trowel with good finishing. After the mortar of the joint is dryed treat the joints with 20% Hydrochloric Acid Solution by means of brush. A.R.lining should be always in contact with Acid and not with water. Concrete subtract like Floor, Wall, tanks and similar surface should be protected with a membrane of Bitrok Mastic or compound steel tanks should be protected with rubber or PVC subjected to chemical conditions and temperature of chemical media. The Brick lining is recommended over the protective layer of Bitrok Mastic. When Bedding and Jointing Materials are Different. Spread the silicate type mortar about 6 to 8 mm thick on the back of the tile or brick. Press the tile on the bed leaving required space for joints between tiles for bricks. After the bedding mortar is set, fill Mp the joints with specified cement.PRODUCT DATA SHEET FOR SK-HB ( K-SILICATE) MORTAR A general purpose cement for acid conditions Resistant to High & medium concentrations of most of the common organic and inorganic acids except Hydroflouric acid. Recommended where the concentration of the acid is high suitable for high temperature. Unsuited to aqueous solutions, alkaline conditions. PREPARATIONS OF MORTAR : * Measure 1 part by weight of K-SILICATE solution into a suitable mixing pan. * Add slowly and gradually 3 parts by weight K-SILICATE mortar and mix thoroughly to form a smooth mortar. * In hot season very large batches of mortar will become stiff quite rapidly therefore small batches, not exceeding 4 to 8 kgs. Will be prepared. * The cement mortar will be used before it starts setting.
This is chemical setting Furan based chemical resistant mortar which is combination of Liquid and Powder, when mixed in proper proportion from workable mortar which after setting and curing give of liquid and give black highly cross linked composites. Furan When set and cured is resistant to highly corrosive acids, alkalis and to powerful organic solvents such as ketones, Aromatic and Chlorinated solvents. It has extreme resistant to Acidic & alkalis, Salts, Greases and Detergents. It resists to Organic & Inorganic acids at their boiling temperature. It is suitable against mild chlorine Gas (dry) phosphorous trichloride, pyridine at room temperature. Furan is especially useful where resistance to mixed media such as aqueous acids /alkalis and organic solvents is needed in chemical plant process and waste streams. Carbon filled Furan is used against corrosive effect of hydrofluoric acid & its salts. PREPARATION OF FURANE MORTAR : Mortar consist of Furan solution and Furan powder. The average mixing ratio necessary to obtain mortar with good working consistency is 1 part by weight Solution & 3 part by weight powder. The ratio will vary slightly depending on temperature and working conditions.Stir the liquid thoroughly before using. Place liquid in a suitable shallow mixing pan. Add powder by weight in the solution mix thoroughly and rapidly until all lumps are dispersed and the mortar is completely homogenous. Spread out the mortar in a thin layer, not more than ¾ thick, to dissipate the heat of reaction and lengthen the working life. Batch size can be varied depending upon the temperature and the speed with which the masons are working. Very large batches will become stiff quite rapidly. Make sure that all the Furan Motrar is used from the pan before another batch is mixed.When working at temperature above 40 C, very small batches not more than 2 Kgs, should be prepared. When working at temperature below 15C the liquid should be kept warm.
DATA SHEET FOR EPOXY EPOXY COATING :- INTRODUCTION - EPOXY COATING (HYB) is a two part high solids solvent free epoxy phenolic resin based coating system designed for hard wearing, smooth surface finish for floors, walls and on steel structures. Nonskid surface finish can be achieved on floor, if required. FEATURES: 1) Hard Wearing 2) Non Dusting 3) Excellent Surface Finish 4) Non Smelling 5) Good Aesthetics 6) Highly Chemical Resistant APPLICATION: 1.Stir well before mixing Part A and Part B and mix in the prescribed ratio. 2.Apply one coat of EPOXY primer on the clean and dry surface. 3.EPOXY COATING (HYB) should be applied on the surface by brush or roller within 24 hrs. After application of primer coat it should be allowed to air dry for min. 4 hrs. Preferable in a dust free atmosphere. 4.Apply min. 2 coats with the intercoat interval of 6-8 hrs. PRODUCT SPECIFICATIONS: Application - Brush, Roller Mixing Ratio - As Directed on Packing Port Life - 30 Mins. Drying Time - Touch Dry- 30 Min, Hard Dry 6 Hrs. - Intercoat Interval 6-8 Hrs. Min. - Dry Film Thickness 125-150 Microns/per coat - depending on porosity Covering Capacity - 6-8 sq.met/kg per coat depending on porosity, roughness & method of application. Color Shades - All Standard Shades RECOMMENDED USES: 1) Food & Pharmaceutical 2) Work Shop 3) Clean Room Application 4) Chemical Resistant Coating for Concrete& Steel 5) Petrochemical, Fertilizer plants METHOD OF APPLICATION: SURFACE PREPARATION The long-term durability of the applied Epoxy coating (HYB) epoxy coating is dependent on the adhesion between sub-base and coating material. It is most important therefore, that the substrate surfaces are correctly prepared prior to application. 1.Before application of the Epoxy coating (HYB) surface should be free from loose partials, rust, oils, grease or earlier coatings and should be totally dry. 2.New concrete or cementations surface should be placed at least 28 days and have a moisture content of less than 5% before application of Epoxy coating (HYB) 3.After surface is dry, all repair work like sealing of joints, cracks filling of cavities and crevices should be carried out. HEALTH & SAFETY - Keep the containers tightly closed when not in use. Avoid contact with skin & eyes. It comes in contact with the body, wash affected parts with plenty of water and contact a doctor. Other known sector for Epoxy floor lining, Epoxy garage floor lining, Concrete epoxy lining, Concrete floor epoxy lining, Epoxy pipe lining, Marine epoxy lining, Sub marine epoxy lining, Basement lining epoxy floor shield, Louisiana, Oregon, Chip lining color epoxy floor, Aviation lining epoxy interior.
Bitumen Primer * Bitumen Primer is Bituminous air curing ready mixed Acid & Alkali resistant special primer. Application * Concrete surface must be clean, dry and rough. No primer should be applied over smooth and wet surface. * After cleaning the concrete surface, one coat of Bitumen Primer should be applied with brush and allow to dry thoroughly. * The drying time will depend upon the temperature. * 24 Month at the temperature 30C (+2OC) Packing * Bitumen Primer: 25 Liter Drum Note * Bitumen Primer contains volatile and slightly toxic solvent. Keep away from spark and open flames at working area. * Bitumen premier it is manufactured using bitumen solution which is used for sealing of prime porous and non-porous surface, and also to protect residential and commercial building. * Bitumen Primer is used to protect substrate against corrosive attack, is suggested to apply anti-corrosive primer.It is best for protection against sub-striate against atmospheric corrosion and chemical corrosion. It is a mixed substance made up of organic liquids that are highly sticky, water proof, viscous,acid proof as with all surface coating, good Bitumen Premier is used for long life of the system. it is applied by brush or roller and allowed to dry before any water proofing treatment so to avoid solvent it is used in defects such as cracks, broken mortar joints, etc. are to be repaired prior to Bitumen primer application. Product Details: Grade Standard Technical Grade Physical State - Liquid Usage - Industrial Color - Black Characteristics: Appearance/Color - Pasty liquid/ black Chemical Base - Bituminous rubber emulsion. Density - 1.0 kg/l Curing Speed/ Rate - 3 - 4 hours Tack free after - 5 - 10 hours Cured after - 2 - 4 days (Dependent on ambient Solid Content by - temperature, substrate temperature, Weight - relative Water Content by weight - humidity and thickness of the coating) Bitumen Content - 41% by weight - Thixotropic (The viscosity can be adjusted by - Viscosity adding up to max. 5% of clean water. - Stir well prior use) - For light protection: 1.0 mm min. Coating - For greater protection: ~ 1.5 - 2.0 mm Thickness applied - in two coats. Water Penetration - 48 h, 1 bar: 78.5 cm2: 0 ml under Hydrostatic - 96 h, 4 bar: 78.5 cm2: 33 ml Pressure - Water vapor 6 x 10-7 mg / hmPa Permeability Service - -30 C to 200 C Temperature - Adhesion Concrete - Very good, Timber: Very good, Metal: Moderate Glass: Poor
PRODUCT DATA SHEET ACID RESISTANT BRICK Material : RED SHALE Type Acid Resistant Brick Size (mm) 230 (LENGTH) X 115 (WIDTH) X 100,76,65,50,40,38,30,25 (THICK) Specification : ASTM C279, ASTM C410, IS 4860-1982 DESCRIPTION : We offer premium quality acid resistant bricks Red â?? Shale , tiles and special shapes. We also offer customized sizes as per clients' requirements. Our acid bricks comply with ASTM C279 Type-III, ASTM C410 Type H, L, and Indian Standard 4860 - 1982 Class-I for all applications where low absorption and high acid resistance is required. FEATURES OF ACID RESISTANT BRICK: Excellent resistant against wide range of chemicals except hydrofluoric acid, high abrasion resistance, low wearing properties, High Thermal resistant to sudden change in temperature AREA OF APPLICATION: Chemical Analysis (Average) Acid and Alkali Storage Tank Farms Demineralization plants and Water treatment plants Chimney inside lining, FGD linings Towers and Columns Process Vessels and Tanks Sewerage Treatment Plants and Lines Industrial Flooring and Bund Areas Chimney and Flue Gas Linings Hoppers and Chutes SiO266.4 Al2 0324 TiO21.1 Fe2 O31.1 K2 O + Na2 O2.5 NOT RECOMMENDED: HF acid or other fluoride solutions Heavy thermal shock Typical Physical Properties of GANESHAS Acid and Chemical Resistant Brick Characteristic RED SHALE ACID RESISTANT BRICK Test Standard Bulk Density, gm/cc - 2.3 to 2.35 ASTM C-20 -Water Absorption, % - 0.1 to 1.5 IS 4860-1968 Apparent Porosity, % -0.5 to 1.75 S 4860 Acid Solubility (H2SO4), Loss in Mass,% -0.1 to 1.8 ASTM C-279 Modulus of Rupture, PSI -2133 to 3555 ASTM C-67 Compressive Strength, Kg/cm2 - 700-900 IS 4860-1968 Abrasion Resistant , Volume in mm3 -69 to 85 EN 102 Surface Hardness, MOHS Scale - 7
PRODUCT DATA SHEET ACID RESISTANT BRICK Material : FIRECLAY Type Acid Resistant Brick Size (mm) : 230 (LENGTH) X 115 (WIDTH) X 100,76,65,50,40,38,30,25 (THICK) Specification : ASTM C279, ASTM C410, IS 4860-1982 DESCRIPTION : * We offer premium quality acid resistant bricks Red â?? Shale , tiles and special shapes. We also offer customized sizes as per clients' requirements. Our acid bricks comply with ASTM C279 Type-III, ASTM C410 Type H, L, and Indian Standard 4860 - 1982 Class-I for all applications where low absorption and high acid resistance is required. FEATURES OF ACID RESISTANT BRICK: * Excellent resistant against wide range of chemicals except hydrofluoric acid, high abrasion resistance, low wearing properties, High Thermal resistant to sudden change in temperature AREA OF APPLICATION: Chemical Analysis (Average) Acid and Alkali Storage Tank Farms Demineralization plants and Water treatment plants Chimney inside lining, FGD linings Towers and Columns Process Vessels and Tanks Sewerage Treatment Plants and Lines Industrial Flooring and Bund Areas Chimney and Flue Gas Linings Hoppers and Chutes SiO266.4 Al2 0324 TiO21.1 Fe2 O31.1 K2 O + Na2 O2.5 NOT RECOMMENDED: HF acid or other fluoride solutions - Heavy thermal shock Characteristic Fireclay Type Acid Resistant Brick - Test Standard Bulk Density, lbs/ft3 - 2.25 to 2.30 ASTM C-20 Water Absorption, % - 0.1 to 1.8 ASTM C-20 Apparent Porosity, % - 4.05 to 4.14 ASTM C-20 Acid Solubility (H2SO4), Loss in Mass,% - 6.1 to 6.8 ASTM C-279 Modulus of Rupture, Mpa - 14.6 ASTM C-67 Compressive Strength, PSI - 15500 to 17250 ASTM C-67 Abrasion Resistant , Volume in mm3 - 71 to 96 EN 102 Surface Hardness, MOHS Scale - 7 Thermal Conductivity, BTU-in/hr-ft-F - 6.94 to 7.12 ASTM C-236 Thermal Expansion Coefficient,in/in/Fx10-6 - 2.6 to 2.8 EN 103