Free sample poly aluminium chloride Coagulant price cas 1327-41-9 pac Yellow White Powder for drinking water Usage: Paper Chemicals, Surfactants, Water Treatment Chemicals Supply Ability 90000 Ton/Tons per Year Packaging Details 25 Kg PP bags with PE inner liner or as your requirements is available Specification Index Liquid Solid Al2O3 % 10.0-15.0 29 Basicity % 40.0-90.0 40.0-90.0 Density (20)(g/CM) 1.12 - Insoluble Substance % 0.1 0.3 PH(1% w/v Liquid Solution) 3.5-5.0 3.5-5.0 Pb % 0.001 As % 0.0002 Cd % 0.0002 Hg % 0.00001 CR % 0.0005
Test Method:Dispersion light nephelometric analysis Test Principle:The highest point on first order differentiation,Percentage analysis Zero point correction:auto track the zero point,eliminate the interference of sample and reagent Wavelength:470nm Light Source:Cold Lamp with high brightness and long lifetime Detector:unique Dispersion light detector with high sensitivity and repeatability,immunized the effect on result of jaundice¡¢hemolysis¡¢chyle and turbidity on plasma Test Channel:each channel is independent,one or more,same or different items can be tested Simultaneously Incubator:Provide reagent and sample with stable incubator, Incubator Temperature:37¡À0.2oC Measure trigger:Auto trigger the measurement through configured pipette Item modify:easy to add or edit items,easy to set the items parameters Calibration:single-point calibration;multipoint calibration;auto store and match with calibration curve Quality control:auto draw the quality figure Reagent:open reagent system Reagent volume:40 Sample volume: 40 Memory:Save more than 10000 samples results,and auto recovering the results when power is off during working Repeatability:CV¡Ü5% Calculative item:S¡¢%¡¢PTR¡¢INR,Fib can be get through PT,This leads to lower the cost of reagent Printer:Inner thermal printer,can be connected to external printer Information edit:easy to input and edit the detail information of patients Interface:RS-232 serial port,can be connected to external printer Working Environment:Temperature:10 oC~30 oC Humidity: ¡Ü70%RH Voltage:85-264V,Auto adapt according to the input voltage Power: ¡Ü80W Quality System:Recognized by CE,TUV and CMD Test Items PT AT-¢ó APTT Protein-S TT Protein-C Fib LA RepT Hep VT. 260mm*257mm*133mm 3.6kg.
Golden Vac plasma blood collection tube promises to provide non-polluting and non-differential original blood specimen for medical test. After centrifugation, plasma can be separated from blood cells effectively. Plasma tube includes 5 kinds of tubes: Clotting Tube with blue cap, Heparin Tube and Gel & Heparin Tube with green cap, Compound of Sodium Fluoride and Anticoagulant Tube with grey cap, Gel& EDTA Tube with lavender cap. Coagulation Tube Coagulation Tube aims to obtain plasma specimen for coagulation function test, it contains buffered Sodium Citrate solution with the concentration of 3.2% �¯�¼?0.109 mol/L�¯�¼?. The mixing ratio of blood to Sodium Citrate is 9:1. This anticoagulant is sustained and stable, it strictly control the microbial limit, making sure the APTT test under the excellent condition. Item GD018SC , Specification Blue cap, Coagulation, 3.2% Sodium citrate 13*75mm, 1.8ml Item GD027SC , Specification Blue cap, Coagulation, 3.2% Sodium citrate 13*75mm, 2.7ml Item GD036SC , Specification Blue cap, Coagulation, 3.2% Sodium citrate 13*75mm, 3.6ml Item GD045SC , Specification Blue cap, Coagulation, 3.2% Sodium citrate 13*75mm, 4.5ml Item GD018SCD , Specification Blue cap, Coagulation, 3.2% Double wall 13*75mm, 1.8ml Item GD027SCD , Specification Blue cap, Coagulation, 3.2% Double wall 13*75mm, 2.7ml Coagulation Tube ( Glass Only) Item GD018SC-F , Specification Blue cap, Glass tube, Coagulation, 10.25*64mm ( flat bottom) , 1.8ml Item GD027SC-F , Specification Blue cap, Glass tube, Coagulation, 10.25*64mm ( flat bottom) , 2.7ml
CHEMICAL NAME: Polymeric ferric sulphate DESCRIPTION: BLUWAT PFS-S series is Poly ferric sulphate powder of direct drying type, a kind of superior performance of inorganic polymer flocculant, appearance is yellow solid, easily soluble in water, aqueous solution of 10% (mass) for the red brown transparent solution, hygroscopicity. Poly ferric sulfate is widely used in drinking water, industrial water, all kinds of industrial wastewater and urban sewage purification, sludge dewatering, etc. It's a safe reliable clarificant. ADVANTAGES: ?No Al+ and Cl-, safe, reliable and nontoxic. ?Rapid sedimentation and good flocculation ?Wide effective PH value and strong applicability comparing with aluminum salt. ?In industry waste water processing, good decolorization and high removing effect on COD. APPLICATION FIELDS: ?Industry waste water treatment (such as the paper making waste water, the printing waster water, the massacre waste water, the automobile manufacturing waste water, the beer factory waste water and so on.), ?Many kinds of industry circulating water treatment (ex, the blast¨Cfurnace gas washing water, the make-up water of the high pressure boiler in the heat and power plant, the industry waste water in biochemical treating factory, the waste emulsifying solution, the opalescent solution and the oil waste water. ?Clarifying agent in Sugar,Medicine,Tanning,Cosmetic etc TYPICAL PROPERITIES: Appearance: Light Yellow Powder Fe3+ Content (%): 19Min. Restore Substances ( Fe2+) Content%: 1.0% Max. Basicity: 9.0-14.0% PH(1% water solution): 2.0-3.0 Insoluble Substances (%):1.5 Max.
Coagulation instrument Used for detecting any kind of heart condition Instruments include a set of reagents such as aptt, ptt Various models available such as the m1, mii
Coagulation Analyzer
Coagulation Analyzer
Serum is one of the main specimens tested in clinical biochemical and immunological tests. At present, the methods of obtaining serum samples in medical institutions are mainly obtained by centrifugation after collecting venous blood after the blood is completely coagulated. Under normal circumstances, it takes more than 60 minutes for an isolated blood sample to completely coagulate, or even not coagulate, which is difficult to meet the needs of rapid laboratory testing. Therefore, shortening the coagulation process and quickly separating serum samples are important factors to improve the efficiency of laboratory medicine. The accelerator was born from this. In vacuum blood collection tubes containing coagulant, fibrin precipitated filaments and lumps sometimes appear, which is caused by the unstandardized use of coagulation blood collection tubes. Choosing a coagulant with too fast coagulation speed in the preparation of vacuum blood collection tubes will cause fibrin to shrink too fast and fragile red blood cells will easily fragment and cause mild hemolysis. Generally, the precipitation of fibrin has the following reasons: Use procoagulant blood collection tube or separation gel to promote coagulation blood collection tube. To make the coagulant evenly distributed in the blood, it must be slightly inverted and mixed 4-5 times to make the center of the blood collection tube and the surrounding blood coagulate at the same time. If the blood is not completely coagulated and then centrifuged, it can cause the precipitation of fibrin. The upper part of the serum appeared jelly-like and fragmented, mixed with the blood. Fibrin filaments are caused by the fact that fibrin has not yet fully contracted. Secondly, when the blood collection tube company prepared the coagulant blood collection tube, the coagulant was not sprayed enough or the prepared water-soluble coagulant was not used up on the same day, and continued use the next day, which resulted in the decrease of the coagulant effectiveness. The fibrinogen in the blood is gradually transformed into insoluble fibrin under the action of the coagulant. If the coagulant dose is insufficient or fails to extend the clotting time, centrifugation can lead to the precipitation of fibrin. Deshengâ??s main products are blood collection tube additives. It has 15 years of R&D and production experience. Coagulant, high-efficiency coagulant powder, heparin sodium, heparin lithium, and serum separation gel are our main products for so many years. With high quality, stable performance and guaranteed after-sales service, everyone is welcome to come to exchange and cooperate.
Specifications Voltageïac220v±22v frequencyï50hz±1 hz Power20va the output voltag12v The monopolar microsurgery electrocoagulator is an ideal tool for stopping bleeding.It's effective and easy to operate.It is small and light in weight, convenient to take and handle. Main applications: applicable to stanch in the superficial surgeries, the coagulation of tissue and burning of neoplasm, etc. Accessories: Electric pen 1 pcs, Electric coagulation head 5 pcs, The power cable 1 pcs.
Range of using : Match to various types of electrosurgical unit. Product characte Operator will control easily for the light material and humanized outline design Waterproof design reduces the risk of electric shock to the lowest.Drug steam sterilization. Long cable and strong copper core ensure the electrosurgical pencil with excellent conductivity and security. Available in push button, rocker switch and foot control configurations Argon beam coagulator pencil.
Blood coagulation analyzer S21 type single channel blood coagulation analyzer Performance Characteristics International standard quantitative methodú¿CLAUSS methodú¬,with unique intelligent software,can decrease measuring interference and fluctuation and make the measurement more accurate Optional PT forward algorithm(DERIVED method) is used to determine fibrinogen,which can save reagent It is equipped with thermostat and thereí»s no need for other water bath cases Little sample and reagent consumption assures tremendous potential to reduce costs Short sample pre-warming time,quick testing speed Full chinese menuíóconvenient operation Two chassis colors is optional Built-in printer,chinese report with normal referenca value is convenient for clinicians to refer Specification Measuring principle: first differential apogee method Measuring wavelength: 70nm Reagent amount: 20-40ª¦L Sample amount: 20-30ª¦L Result storage:6000 items Calculation function: Síó%íóPTRíóINRíóg/L conversion Calibrated curve:automatic storage, automatic calling Temperature control precisionú¦37íµí+0.5íµ Sample-adding gun: photoelectric trigger, automatic trigger measurement Testing cup: truncation pyramidale cup Stirring function: automatic magnetic stirring Display: 19264 LCD Interface: RS232 standard serial port Main Analytical Items Prothrombin time Activated part thrombin time Fibrinogen Thrombin time Crawler enzyme time Internal shock coagulation factoró°íóó(íóóvíóón External shock coagulation factoró=íóó)íóóníóó· Protein S Protein C lupus anticoagulant analysis Anti-Xa factor heparin detection S22 type dual-channel blood coagulation analyzer Two testing channels The testing of two different items at the same time Online sample-adding device Full chinese display S24 type four-channel blood coagulation analyzer Four testing channels The testing of four different items at the same time Online sample-adding device Full chinese display
Qpj-300*800 Patented products! diminutive coagulated latex slicer It is a new machine designed and manufactured base on our years of experience for ribbed smoked sheet(rss) process. It is used in slicing coagulated latex black into think coagulated sheet for next process. In traditional rubber sheet process, latex is coagulated in a tray, and rolled by manual operation, and dewatered in sheeting machine afterwards. Rubber factories are going out of this type of processing method as it brings shortcomings of high labor intensity, low efficiency and so on. Base on the market demand we have invented this coagulated latex slicer which changes the traditional method in rss process. The latex is coagulated in a tank as a coagulated block and sliced into thin sheet which is suitable to feed the sheeting machine. This machine slices rubber block into rubber sheets with high efficiency, low labor intensity, high automatic level and less occupied ares. It is one our patent products which is highly recommended. -
More about Alyumoflok Coagulants based on aluminum salts, hydroxychloride or hydroxysulfochloride of aluminum ALUMOFLOK-SI , ALUMOFLOK-10 , ALUMOFLOK-13 , ALUMOFLOK-17 are coagulants used for cleaning drinking and economic and industrial water. The mass fraction of the main substance in terms of Al 2 O 3 .% is not less - 13-23 % Relative basicity, % - 35-90 Density at 20 C, g/cm 3 - 1.2-1.4
Usage: Used for blood coagulation, it can speed up blood coagulation in blood collection tubes in a short time, facilitate the separation of serum that used for in vitro diagnostic testing. It can be made into serum-type vacuum blood collection tubes such as coagulation tube, separation gel & coagulation tube, etc. Characteristics: 1. The blood Coagulation powder Desheng company develops and produces greatly shortens the blood coagulation time. The initial coagulation only takes 7-10 minutes, and the complete coagulation is 15-20 minutes 2. Blood coagulants are commonly used in the market. also has coagulant products, but its main raw material is blood coagulation powder. In order to facilitate storage and transportation and save costs for customers, has launched blood coagulation powder. Configuration methods and usage methods also has professionals online or on-site teaching throughout the process; 3. blood coagulation powder is added to prevent fibrin from hanging on the wall, which can effectively avoid the phenomenon of wall hanging at low temperature;
- Quick bod and cod reduction, color and pollutant removal - cost-effective and eco-friendly replacement for coagulants, flocculation agents - efficient from 0.1% on. 20kg bag.
Suction Coagulator 10 Fr. Control Valve Vent UOM: 25/BX Product Number: 004025 Manufacturer: J & J
Poly Aluminium Chloride (PAC) PAC Solid professional polyaluminium chloride manufacturer for drinking water treatment Cas No.:� 1327-41-9 Molecular formula: [Al2(OH)nCL6-n]m� Appearance: Light Yellow Granule or Powder ITEMS PRODUCT GRADE Drinking Water Grade Industrial Grade Content % 28-32% 25-28% Basicit % 40-90 40-90 PH 3.5-5.0 3.5-5.0 Water insoluble matter% 1.0 1.0 Product Description: Poly Aluminium Chloride is an inorganic high-molecular� polymer with gelling� property. It could be used as cementing� material in fireproofing material, Ultrapure alumina products, refractory concrete etc. Application:Poly Aluminium Chloride is an flocculant mainly used in the purifying of drinking water. It is also used in the special water treatment, such as removal of iron, cadmium, fluorine, radioactive pollutant, oil slick etc. It could also be used in industrial waste water treatment, such as the waste water treatment of dying industry. It is also widely used in the foundry industry, paper making industry, pharmaceutical industry, leather industry etc. If you have any demand about my products. please enquiry mesophia at kaihongchem dot com. Our main products are 2-Ethyl-anthraquinone. Aluminum Chloride.Polyaluminium Chloride PAC. Bronopol. DBNPA. HBCD.Carbohydrazide. SodiumBromide. DBNE DBNPA20%.2,2-Cyanoacetamide. HBCD Masterbatch. BDDP. Sodium bromate. Flake Graphite etc.
Qpj-300*800 Patented coagulated latex slicer/rubber machine It is a new machine designed and manufactured base on our years of experience for ribbed smoked sheet(rss) process. It is used in slicing coagulated latex black into think coagulated sheet for next process. In traditional rubber sheet process, latex is coagulated in a tray, and rolled by manual operation, and dewatered in sheeting machine afterwards. Rubber factories are going out of this type of processing method as it brings shortcomings of high labor intensity, low efficiency and so on. Base on the market demand we have invented this coagulated latex slicer which changes the traditional method in rss process. The latex is coagulated in a tank as a coagulated block and sliced into thin sheet which is suitable to feed the sheeting machine. This machine slices rubber block into rubber sheets with high efficiency, low labor intensity, high automatic level and less occupied ares. It is one our patent products which is highly recommended. -
Features: Parameters: PT, APTT, TT, FIB. Etc Principle: Clotting, optical method Principle: Clotting, optical method Precise electronic pipette Micro sample volume Automatic start at reagent addition Thermal printer, auto&manual print Support LIS Specification Testing channel:        BCA101:1                      BCA102:2                      BCA104:4 Display:              BCA101: 4.3 inch screen                      BCA102/104:5inch screen Cuvette incubation positions:       BCA101:5                              BCA102:12                              BCA104:24 Reagent incubation positions:      BCA101:2                              BCA102:5                              BCA104:6 Wavelength:                   LED470nm Sample type:                   Plasma Memory:                      10,000 results storage Sample volume:                20-40L Reagent volume:               20-40 L Eletronic pipette:               20-200L Avaible dimensions:             Seconds, ratio, %, g/L Incubation temperature:          37±1.0C Relative humidity:               85% Precision:                     PT, APTT,FIB5%;TT8%                              (Normal sample) Divation between channels:       5% Power supply:                 AC 100-240V 50/60Hz BCA101:                  2.1kg BCA102:                  4.5kg BCA104:                  5.2kg