MEGA 600 Full Digital Mammography System Intelligent control The forming mold and streamlined appearance satisfy the ergonomic design concept. Large size color LCD touch screen operation and display Isocenter electric rotating U-arm,one-click automatic reset function Electric compressor adopts flexible compression system,with the function of automatic pressure and quick release,so that make the patients comfortable in the whole process of the examination. Sharp image Specialized mammo flat panel detector digital imaging technology,make high image contrast,less exposure time,low skin dose. Improve low energy X ray absorption efficiency effectively,high DQE value,small pixel size and higher spatial resolution. Support networking Mammo image acquisition control workstation,fully compatible with Dicom3.0,can be connected to RIS/HIS/PACS seamlessly. Proprietary intellectual property rights All soild state quasi resonant high frequency high voltage generator,supported by the National Innovation Fund,got USA patent. We have software copyright matching with the products.
DESCRIPTIOn: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT: 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY : Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND counter Balance Mobile
DESCRIPTION: Titanx RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Floor to Ceiling Column Stand
DESCRIPTION: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Counter Balance Mobile
DESCRIPTION- TITANX 100 RADIOGRAPHY RATING- 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT 8KW RECTIFICATION- Full Wave Rectified TIMER- 0.06 to 5 sec DIGITAL DISPLAY- Digital Display of mAs, kV & mA X-RAY TUBE- XD-3/Imported POWER SUPPLY- 230 Voltage AC, 15 Amps LINE REGULATION- 10% 0.6max PROTECTION- Electronic overload Protection TUBE STAND- Spring Balance
The features of mammography x ray system : Mammography x ray system is integrating designed, with beautiful appearance, manual operation, convenient operation and use;use the most popular keyboard, optical mouse operation;large screen high resolution colorful display, low radiation, clear and bright image. 1 high-definition and colorful display2 multiple function and easy operation3 radiationless, no-invasive, long life-time4 mouse action, convenient operation Mammography x ray system: Etect galactocele accurately;2 detect intraductal papilloma;3 detect mammary duct ectasia and acute mastitis:4 detect proliferation of mammary gland and breast cancer. Weight: 240kg Density adjustment:16 density steps Wooden box
PLX101 Series High Frequency Mobile X-ray Equipment PLX101/101A/101C Rocker safety lock design, make your operate much safer High quality x-ray monoblock assures more details, less dose Symmetrical adjustable collimator for accurate positioning and better exposure protection Aviation aluminum connectors, connection reliable, more safety Advanced dislocation braking system, flexible movement, flexible braking Multifunctional cassette storage box design Features Our high frequency technology assures the best image in every operating condition Along with reduced patient dose and extended x-ray tube life time The generator provide the right amount of penetration, reducing exposure times and retakes. The parameter can be adjusted by the kV and mAs. Multiple security protect function such as over-voltage, over-current. 50 preset exposure programs allow extensive possibilities to optimize the exposure and processing parameters according to your preferences. Fault automatic protection setting and fault alarming display Parameters are automatically storage when power cut off. Adopt rotating beam limiting device to adjust the X-ray field and angle freely. Adopt manual controller and remote controller to do exposure. Optional: PLXF152 mobile table for high frequency mobile X-ray equipment. PLX101D is equipped with built-in battery, can take 200 films when full charged. Rocker can move up and down, automatically balance High quality X-ray monoblock can rotate in ±90 Options PLXF152 Mobile Bed For Mobile X-ray Machine Size: 2000 X 700X 500mm Range of grid box movement 1210mm Size of grid box: 430X 430(17 X 17) Bucky Stand Height: 1770mm Vertical movement range: 470-1470mm Grid density: 103L/inch Grid radio: 10:1 Focus distance: 150cm Maximum grid box: 17 X 17 Technical Parameters
Application of x-ray device for mammography with IAE tube MEGA 600 1 Detect galactocele accurately 2 Detect intraductal papilloma 3 Detect proliferation of mammary gland and breast cancer Features of x-ray device for mammography MEGA 600 1 New Molding shell 2 Three large full color LCD involved 3 Touch Screen 4 Electric isocentric rotating U-arm with an unique automatic back to center function 5 Optional flexible compression systems 6 Optional electric filter 7 Optional digital imaging function:CR or DR 8 Original mammary texture examination function 9 Optional import all-Solid transducer AEC
3ply face mask comfortable for user. The face mask is latex free and use brand new hypoallergenic material, odourless and lint free. Product Disposable 3-Ply Non-Woven Face Mask with Ear Loop Size 18cm x 9.5cm (18cm after expended) Color Blue/Green/White/Yellow/Pink or can be customized Outer Layer Spund-bound PP Nonwoven: 20 - 25 gsm Filter Medium Meltblown PP Nonwoven: 18 - 20gsm Inner Layer Lint free ES Nonwoven: 25 gsm Nose Piece Aluminum Packaging 50 pieces per box or 50pcs per bag; 10 boxes/bags per carton. 1600 cartons/20 ft container , 3200 carton/40 HQ container. MOQ 50,000 pieces min order Quantity: 10,000PCS/Day MOQ : 10,000 pieces Packaging: 50 pieces per box/bag; 40 boxes per carton. Payment condition: TT Shipping Duration: 7 Days ( ONE WEEK) Origin: Thailand/China Condition: Subject to availability
X ray machines, Mammography machines, digital Xray, OPG machines, C Arm, dental Xray, Portable X ray.Manufacturing and export
Specifications: Tube Voltage): 60kV Tube Current: 1mA Exposure Time: 0.02~2S Tube Focus: 0.3*0.3mm Frequency: 30kHz Battery: DC14.8V 6400mA Rated Power: 60VA Charger Input: AC100V-240V±10% Charger Output:DC16.8V Weight:2.2kg Size:138*165*185mm The distance from skin to cone: 130mm
100 mA, 100 KVP Mobile X-ray Machine 100mA, 100 KVP, Mobile X-ray Machine for Radiography only Electronic Timer Electronic Overload Protection Device Stationary Anode X-ray Tube : BEL or Imported Collimator Counter Balanced Mobile Stand Suitable for Bed Side X-rays
We're a leading XRay machine and accessories manufacturer company with over 29 years of experience and global presence and distributor network in 7 different countries. We have Line Frequency & High Frequency, APR X-Ray Machine, Dental X-Ray Machine, Mobile 100MA X-Ray Machine, 300MA X-Ray Machine, 500MA XRay Machine, Vertical Bucky, Multi-Position Bucky Table, 4 & 2 Way Floating Bucky Table Etc Beside new machines, we offer complete modification & repairing of any brand XRay machines, Rotating Anode Tube Head, HT 100MA, 300MA, 500MA Etc
Power Output 5.0KW x ray machine Main Inverter frequency 40 KHz X-ray Tube of radiography machine fixed anode focus: 1.5 (X-ray tube for high frequency) Power Supply 220V�±10% 50Hz Inner-resistance â?¤1.0�© Operation Method Wire/wireless control mobile x-ray machine safety mobile x ray machine cost mobile x ray machine price
2.5kw high frequency portable X-ray machines PLX101 x ray tube Fixed Anode Power Output of x ray machine 2.5kW Frequency 25kHz Tube voltage 40~100kV Power Supply 220V�±10%, 50kHZ Operation Method Wire/ Wireless control price list of x-ray machine price of 500ma x-ray machine price of medical x ray machine
X-ray machine Technical parameter 1. The numbers of x-ray tubes used in the product are also used as product number and x-ray generator (bulb tube head) number. 2. The current and voltage of x-ray tubes are fixed in three groups, they are: X exposure voltageú¿kvpú¬ 60 65 70 X-ray currentú¿maú¬ 0.50 0.85 1.10 3. When adding up voltage, total current is less than 2a and total power is 500w 4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1 5. The three groups of voltage (60kvíó65kvíó70kv) are adjustable. 6ú«wireless remote control in any angles within 10 meters part form the control box 7. The parameter of x-ray generator (bulb tube head) 7.1. The parameter of x-ray tubes A. Focus index: 0.3í-0.3mm2 Bú«the voltage of the-highest-voltage generator: 90kv C. The highest inverse peak voltage: 90kv D. Filament characteristic: vf=5ví+0.5vú¼if=3a E. Target surface obliquity: 12íp F. The cooling manner of bulb tube head: oil immersion 8.7.2 the parameter of x-ray generator (bulb tube head): A. Focus-skin distance: 200mm B. The thickness of filter-ray film: more than 1.5mmal C. The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h) D. The manner of limiting beam: using planigraphic device
Technical parameter 1. The numbers of x-ray tubes used in the product are also used as product numbers and x-ray generator (bulb tube head) numbers. 2. The current and voltage of x-ray tubes are fixed in three groups, they are: X exposure voltage (kvp) 60 65 70 X-ray current (ma) 0.50 0.85 1.10 3. When adding up voltage, total current is less than 2a and total power is 500w 4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1 5. The three groups of voltage (60kv, 65kv, 70kv) are adjustable. 6. Wireless remote control in any angles within 10 meters part form the control box 7. The parameter of x-ray generator (bulb tube head) 7.1. The parameter of x-ray tubes A. Focus index: 0.3í-0.3mm2 B. The voltage of the-highest-voltage generator: 90kv C. The highest inverse peak voltage: 90kv D. Filament characteristic: vf=5ví+0.5v, if=3a E. Target surface obliquity: 12íp F. The cooling manner of bulb tube head: oil immersion 7.2 the parameter of x-ray generator (bulb tube head): A. Focus-skin distance: 200mm B. The thickness of filter-ray film: more than 1.5mmal C. The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h) D. The manner of limiting beam: using planigraphic device
100 mA Mobile x-ray machine. very good image quality. built in stabilizer. works on 220v AC.
Tube stand (xts-01) Type : floor-to-ceiling rail Distance of longitudinal travel : 2550mm Distance of vertical travel : 1600mm Rotation of x-ray tube : ±180° Lock system : electromagnetic lock by manual Weight : 170kg Ceiling (xce-01, option) Type : ceiling rail Distance of longitudinal travel : 2800mm Distance of vertical travel : 1200mm Rotation of x-ray tube : ±180° Lock system : electromagnetic lock by manual Weight : 130kg Bucky stand (xbs-01, option) Type : vertical travel Distance of vertical travel : 120mm ~ 1780mm X-ray grid : grid ratio of 8:1, 103 line/inch Front plate to film distance : 50mm Weight : 105kg 4way type bucky table (xbt4-01) Type : 4way travel Longitudinal distance of tabletop sliding : 420±5mm Lateral distance of tabletop sliding : 120±5mm Tabletop to floor distance : 665mm X-ray grid : grid ratio of 8:1, 103line/inch Dimensions : 2000l x 750w x 665h (mm) Weight : 150kg 6way type bucky table (xbt6-01, option) Type : 6way travel Drive type : electric motor drive X-ray grid : grid ratio of 8:1, 103line/inch Longitudinal distance of tabletop sliding : 420±5mm Lateral distance of tabletop sliding : 120±5mm Vertical distance of tabletop : 300±5mm Tabletop to floor distance : 689(880)mm Dimensions : 2000l x 750w x 680(880)h (mm) Weight : 170kg High voltage cable (hvc-6/8) Length : 6m/8m Maximum voltage : dc 75kv The number of core line : 3 lines