"AC POWER: 220VAC, 50 Hz. BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge. Maximum battery charger capacity: 18AH battery. NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box. Total DC24V system power: 3.0 amps. Maximum current per NAC: 1.25 amps. Maximum battery charging capability: 18 AH. Resettable four-wire smoke detector power output. Non-resettable power output.
AC POWER: 220VAC, 50 Hz. BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge. Maximum battery charger capacity: 18AH battery. NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box. Total DC24V system power: 3.0 amps. Maximum current per NAC: 1.25 amps. Maximum battery charging capability: 18 AH. Resettable four-wire smoke detector power output. Non-resettable power output. Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive).
1. General Conventional Fire Alarm Control Panel with four Zones 2. Specifications Two Style B (Class B) Initiating Device Circuits (IDCs). All zones accept two-wire smoke detectors and any normally-open contact devices. One built-in Fire Fighting Ouput. 24-volt operation. Resettable four-wire smoke detector power 500 mA. Non-resettable power 500 mA. One-man walk-test programmable for silent or audible test. Disable/Enable control per IDC. Reverse polarity protection. 3. Packaging and shipping Conventional Fire Alarm Control Panel with four Zones 1 pc/carton box;carton M:43*17*51cm
The 4001 non-addressable control and indicating equipment forms the central part of a fire detection and alarm System. The 2-wire 4001 is compatible with numens non-addressable devices The 4001 comes standard with features that allows flexibility and expandability. Default configuration programming Facilitates out-of-box installation and rapid commissioning. 2, 4, 8, or 16 detection zones Up to 32 non-addressable devices per alarm zone circuit Configurable non-latching alarm zones, alarm dependency (zone coincidence detection), and output delay timer 3 access levels Single-person test mode Day/night mode Manual activation of audio/visual alarm devices Supervised auxiliary dc 24 v output 2 independently programmable non-addressable a/v alarm output circuits 2 programmable fire alarm relay outputs Fault relay output 3 voltage-free inputs for remote reset, evacuation start/stop, and day/night mode Supports up to 7 repeater panels
We have range of patch fittings suitable for 8-15mm tempered glass doors. 1. Our patch fittings are suitable for 10mm, 12mm tempered glass doors 2. Bottom Patch fitting. 3. Top patch fitting. 4. Side Over panel. 5. Top center 6. Inserts available for most of the floor springs. 7. Aluminum, SS304. 8. Polished Stainless steel, Satin Stainless steel,aluminium oxsilver ,Aluminum Gold color.
1.We use imported base paper from Germany. For solid color, base paper most 80 to 120GSM. For wood base paper is between 70-85 gsm 2. High quality water-base ink- Available over 200 shades in Solid colors and wood grains 3. With clear texture ,high Fidelity meeting international standards. 4. With smooth surface coating 5. Germproof, mould proof, antistatic and wear-resistance. 6. Green environmental protection and Odorlessness which Conforms to the GB18584-2001 standard requirement 7. Can be used for the hot press molding craft, the production efficiency is high. 8. Melamine paper takes shape easily, is widely used for the panel furniture and the decorative yarn. Product Specification: Width: 1230-1260mm or 1300-1800mm Length: 500-1000m For storing: Put it in room to a cool and dry place keep the temperature 20-25°C in room. The best humidity is: 50-60% We can also give you complete decorative solution with Matching Melamine Edge Banding, PU Paper. If you need just need Melamine/prelaminated boards either in MDF / Particle board we can also do so
Name : Weed control mat/Ground cover/ 1. Weight 2oz/sm - 14oz/sm or 60gsm-150gsm 2. Width 1.6' -20' or 0.5m-6m 3. Roll Length 16', 33', 65', or 5m,10m,20m,25m,50m,100m or as required 4. Color Black,Green,Black-green or as required 5. Weave 8*8,10*10,11*11,12*12,12*16 6. Material 100% PP material 7. UV resistance 3-5 years 8. Sample Avaliable 9. Delivery time About 20 days 10. Min order No limit 11.Terms of payment 1.TT or LC 12. Supply capacity 500 tons per month 13. Packing In rolls with paper core inside and polybag outside or in Carton or as your request 14. Quantity 1x20ft container can load about 11 tons 1x40'HC can load about 26 tons 15.Export market Australia,Canada,Argentina,USA,The Middle East,Europe market ,Japan and so on.
AC POWER: 220VAC, 50 Hz. BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge. Maximum battery charger capacity: 18AH battery. NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box. Total DC24V system power: 3.0 amps. Maximum current per NAC: 1.25 amps. Maximum battery charging capability: 18 AH. Resettable four-wire smoke detector power output. Non-resettable power output. Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive).
Features External (key-switch operated): Reset/resound/test zone lamps evacuate Silence alarm sounders Silence fault sounders Internal: One man detector test Zone isolate Revert to short-circuit: fire (no resistors in call points) External indicators: Sounder fault Battery/power supply fault Mains on Zone fire Zone fault Internal indicators: Open circuit zone fault Short circuit zone fault Zone isolated Engineer test selected Outputs: Two sounder circuits (alarm relay contacts can be obtained by connecting a relay to a sounder circuit) Ancillary connections for expansion modules will allow the following: Repeater panels Multiple sounder outputs Connection to landlord panel
"AC POWER: 220VAC, 50 Hz. BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge. Maximum battery charger capacity: 18AH battery. NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box. Total DC24V system power: 3.0 amps. Maximum current per NAC: 1.25 amps. Maximum battery charging capability: 18 AH. Resettable four-wire smoke detector power output. Non-resettable power output. Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive)."
2zone MINI Conventional Fire Alarm Control Panel Fire Alarm Host/Master Panel /Slave Panel Product Features 1. 2 conventional input zones. 2. 1 notification appliance circuits (NAC) with built-in synchronization forANSI 3.41and Gentex. 3. The panel comes with a 2 amp power supply. 4.Dedicated alarm and trouble relays. 5.1 RS485 can be able to connect the other panel. 6. Housed in a 205mm W x 258mm H x 81mm D metal enclosure. 7. Enclosure supports two 12V, 4Ah backup batteries. 8.The panel can be used independently or connect by RS 485. Specifications Primary AC 120VAC 50/60 Hz Power supply rating 240VAC 50/60 Hz Power supply rating 2 Amps @ 24VDC Maximum Battery Charging Current 0.98 Amps @ 26VDC Initiating Device Circuits 2 Zones Alarm Zone 2 Normal Initiating Operating Voltage 23VDC, Maximum 26VDC, regulated Normal Quiescent Current (normal status)
Capsicum Oleoresin is prepared by extracting the crushed capsicum (Capsicum Annum Linn) with volatile solvents by percolation method. It contains the pungent principles, capsicin not less that 8 percent. It also contains the red colouring matter called Capsanthin. This product is a powerful irritant and a carminative, which is also used as a counter irritant in lumbago and neuralgia. It can also be used to treat stomach ache that involves poorly functioning stomach muscles and as an antibacterial agents. Extraction of oleoresin capsicum from peppers involves finely ground capsicum, from which capsaicin is extracted in an organic solvent such as ethanol. The solvent is then evaporated, and the remaining wax like resin is the oleoresin capsicum. An emulsifier such as propylene glycol is used to suspend the OC in water, and pressurized to make it aerosol in pepper spray. The high performance liquid chromatography (HPLC) method is used to measure the amount of capsaicin within pepper sprays. Scoville Heat Units (SHU) are used to measure the concentration or "heat" of pepper spray. A synthetic analogue of capsaicin, pelargonic acid vanillylamide (desmethyldihydrocapsaicin), is used in another version of pepper spray known as PAVA spray which is used in the United Kingdom. Another synthetic counterpart of pepper spray, pelargonic acid morpholide, was developed and is widely used in Russia. Its effectiveness compared to natural pepper spray is unclear. Pepper spray typically comes in canisters, which are often small enough to be carried or concealed in a pocket or purse. Pepper spray can also be bought concealed in items such as rings. There are also pepper spray projectiles available, which can be fired from a paintball gun. It has been used for years against demonstrators. Derived from chilli peppers, oleoresin capsicum is the active ingredient in pepper spray and in some topical pain relievers.
Refractory bricks, high alumina bricks, acid proof bricks, tiles and castables, all mortars and fire clay, low cement castables, insulating castables, conventional dense refractory bricks, insulation bricks, cold face, hot face insulation bricks, hot face insulation bricks, acid resistant bricks/components, membranes, acid resistant cement, construction chemicals, class 1 ar tiles and bricks 38mm and 75mm, 4457 vitrified ar tiles with 0% water absorption, 20mm & 25m, primer, mastics, pot. silicate cement, coerce cement, furnace based cement, crushed refractory boiler bed material, acid resistant tiles, acid resistant brick fireclay type, acid resistant brick red shale type, bitumen primer, epoxy resin & hardner, furan powder and syrup solution,.
Trichloroisocyanuric acid (TCCA) 90% Min intro: 1. Molecular formula: C3N3O3C13 Molecular Weight: 232.44 CAS: 87-90-1 HS NO:29336922 UN NO:2468 2. Structural formula: 3. Uses: 1) water treatment: it can be used to disinfect drink water and water in swimming pool, algae-removing in circulating water. 2) Disinfection: It can be used in disinfecting dinner, food, and dishes, or used in the prophylactic disinfection of home, hotel and public place; hygiene and disease control of hospital; or used in the disinfection of silk worm, animals, birds and fish 3) Other: It can be used in anti-shrinkage finishing of wool, textile bleaching, antimoth of paper and chlorinated agent of rubber. 4. Technical Index: Appearance: white powder/granular Available chlorine: 90%Min PH (1% Aq. Solution): 2.7-3.3 Moisture: 0.5% Max Granular Size: 8-30mesh or 20-60mesh Package: 25kg/50kg plastic drum, 50kg fiber drum. 5. Product: According to the requirements of production from customers.
Power Supply: AC 240V 50/60Hz Stand-by Battery: DC24V Sealed Maintenance-Free Lead-Acid Battery Charging Voltage: DC26.4V Below 450mA Trickle Charging Circuit Voltage: DC24V Short Circuit Voltage 5V below 32mA Loop Resistance: Below 50+ back and forth Detector Installation: No limit in the number of differential detector & constant-temperature detectors used; smoke detectors or electronic differential detectors; each ciruit can connect to a maximum of 16 smoke detectors (monitoring current for detectors: DC24V 40¦A) Terminal Resistor: 10k+ Number of indicators: 1 time the number of panel circuits Number of Local Alarm: 1 time the number of panel circuits. Number of circuit & Dimension: 1L/2L/4L/5L/8L (330x280x120mm) 12L/16L(400x300x120mm) 24L(495x300x120mm).
AC POWER: 220VAC, 50 Hz. BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge. Maximum battery charger capacity: 18AH battery. NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box. Total DC24V system power: 3.0 amps. Maximum current per NAC: 1.25 amps. Maximum battery charging capability: 18 AH. Resettable four-wire smoke detector power output. Non-resettable power output. Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive).