Please click here to check who's online and chat with them.

Find Verified Others Suppliers, Manufacturers and Wholesalers

Top Supplier Cities : Istanbul   -   Ankara  
Jul-31-07
Supplier From Kayseri, Turkey
Aug-28-08
Supplier From Bursa, Turkey
Apr-14-09
Supplier From Istanbul, Kadikoy, Turkey
May-22-09
Supplier From Istanbul, Turkey
Jul-09-08
Supplier From Istanbul, Turkey
3743 Others Suppliers
Short on time? Let Others sellers contact you.
Jul-14-09
Supplier From Istanbul, Turkey
Aug-17-09
Supplier From Izmir, Turkey
Apr-05-10
Supplier From Istanbul, Turkey
Jul-21-10
Supplier From Istanbul, Turkey
Jan-12-11
Supplier From Kayseri, Turkey
Apr-10-13
Supplier From Izmir, Turkey
May-06-13
Supplier From Kayseri, Turkey
Sep-20-12
Supplier From Istanbul, Yenibosna, Turkey
Sep-18-13
Supplier From Istanbul, Esenyurt, Turkey
Dec-16-22
 
FP 250
Engine
Engine Model : 1206A- E70TTAG2
Stand By kVA: 250
Stand By kW : 200
Prime kVA: 227
Prime kW : 182
Rated Current : 327

Engine
heavy duty diesel engine
12V starter and charge alternator
Replaceable air, fuel and oil filters
Mechanical governor control
Tropical type radiator
Flexible fuel hose
Oil drain valve and extension hose
Industrial type silencer and steel compensator
Maintenance-free starter battery
Water jacket heater
1500 rpm engine speed

Alternat
IP 21-23 Protection Standard
H Insulation Class
50 Hz Frequency
4 pole brushless synchronous type alternator
Automatic Voltage Regulator (AVR)
400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
Convenient design for easy lifting and carrying
High standard sound proof canopy design
Modular design with easily removable nuts - bolts
Lockable doors
Transparent window for watching Control Panel
Electrostatic powder painted, providing protection against harsh weather conditions
Emergency STOP button
Fuel tank inside the chassis
Anti-vibration wedges (engine - chassis and chassis ground)

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine
Engine Model 1206A- E70TTAG2
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 15.08:1
Bore 105
Strok 135
Displacement Lt 7,01
Air Intake Turbocharged aftercooled
Speed (RPM) 1500
Oil Capacity Lt 16,5
Standby Power kw / Hp 226 / 303
Prime Power Hp 204 / 273
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 25
Fuel Consumption (lt / h) Lt Full Load 50,6
Lt %75 LOAD 37,9
Lt %50 LOAD 25,2

Frequency Hz
Power kVA 200
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8

Weight (Silent) Kg 2550
Weight (Open) Kg 2120
Width (Silent) Mm 1300
Length (Silent) Mm 3900
Height (Silent) Mm 1980
Fuel Tank Capacity Lt 450

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Dec-09-22
 
EAP 220
Engine:
Engine Model : 1106A-70TAG4
Stand By kVA: 220
Stand By kW : 176
Prime kVA: 200
Prime kW : 160
Rated Current : 288

Engine
heavy duty diesel engine
12V starter and charge alternator
Replaceable air, fuel and oil filters
Mechanical governor control
Tropical type radiator
Flexible fuel hose
Oil drain valve and extension hose
Industrial type silencer and steel compensator
Maintenance-free starter battery
Water jacket heater
1500 rpm engine speed

Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine
Engine Model 1106A-70TAG4
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 16:01
Bore 105
Strok 135
Displacement Lt 7,01
Air Intake Turbocharged and air charge cooled
Speed (RPM) 1500
Oil Capacity Lt 18
Standby Power kw / Hp 196.3 / 265
Prime Power Hp 178.9 / 242
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 22
Fuel Consumption (lt / h) Lt Full Load 45,8
Lt %75 LOAD 34,7
Lt %50 LOAD 23,1

Frequency Hz
Power kVA 200
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
DIMENSIONS
Weight (Silent) Kg 2270
Weight (Open) Kg 1940
Width (Silent) Mm 1200
Length (Silent) Mm 3500
Height (Silent) Mm 1850
Fuel Tank Capacity Lt 360

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Dec-08-22
 
EAP 200
Engine Model : 1106A-70TAG3
Stand By kVA: 200
Stand By kW : 160
Prime kVA: 182
Prime kW : 145
Rated Current : 262

Engine
heavy duty diesel engine
12V starter and charge alternator
Replaceable air, fuel and oil filters
Mechanical governor control
Tropical type radiator
Flexible fuel hose
Oil drain valve and extension hose
Industrial type silencer and steel compensator
Maintenance-free starter battery
Water jacket heater
1500 rpm engine speed

Alternat
IP 21-23 Protection Standard
H Insulation Class
50 Hz Frequency
4 pole brushless synchronous type alternator
Automatic Voltage Regulator (AVR)
400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
Convenient design for easy lifting and carrying
High standard sound proof canopy design
Modular design with easily removable nuts - bolts
Lockable doors
Transparent window for watching Control Panel
Electrostatic powder painted, providing protection against harsh weather conditions
Emergency STOP button
Fuel tank inside the chassis
Anti-vibration wedges (engine - chassis and chassis ground)

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine Model 1106A-70TAG3
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 16:01
Bore 105
Strok 135
Displacement Lt 7,01
Air Intake Turbocharged and air charge cooled
Speed (RPM) 1500
Oil Capacity Lt 16,5
Standby Power kw / Hp 180.2 / 243,5
Prime Power Hp 162.7 / 220
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 22
Fuel Consumption (lt / h) Lt Full Load 41,5
Lt %75 LOAD 31,8
Lt %50 LOAD 20,2

Frequency Hz
Power kVA 200
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8

Weight (Silent) Kg 2190
Weight (Open) Kg 1850
Width (Silent) Mm 1200
Length (Silent) Mm 3500
Height (Silent) Mm 1850
Fuel Tank Capacity Lt 360

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Nov-23-22
 
EAP 165
Engine:
Engine Model : 1106A-70TAG2
Stand By kVA: 165
Stand By kW : 132
Prime kVA: 150
Prime kW : 120
Rated Current : 216

Engine
heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed

Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine
Engine Model 1106A-70TAG2
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 18,2 : 1
Bore 105
Strok 135
Displacement Lt 135
Air Intake Turbocharged and Air Charge cooled
Speed (RPM) 1500
Oil Capacity Lt 18
Standby Power kw / Hp 149,1 / 202
Prime Power Hp 136 / 184
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 22
Fuel Consumption (lt / h) Lt Full Load 33,2
Lt %75 LOAD 24,5
Lt %50 LOAD 16,2

Frequency Hz
Power kVA 165
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8

Weight (Silent) Kg 1950
Weight (Open) Kg 1710
Width (Silent) Mm 1000
Length (Silent) Mm 3150
Height (Silent) Mm 1700
Fuel Tank Capacity Lt 250

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Nov-17-22
 
EAP 150
Engine Model : 1106A-70TG1
Stand By kVA: 150
Stand By kW : 120
Prime kVA: 136
Prime kW : 110
Rated Current : 195

Engine
heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed

Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis ground)

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine Model 1106A-70TG1
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 18,2 : 1
Bore 105
Strok 135
Displacement Lt 7,01
Air Intake Turbocharged
Speed (RPM) 1500
Oil Capacity Lt 18
Standby Power kw / Hp 135,8 / 183,5
Prime Power Hp 122,7 / 166
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 22
Fuel Consumption (lt / h) Lt Full Load 30,1
Lt %75 LOAD 21,9
Lt %50 LOAD 15,2

Frequency Hz
Power kVA 150
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8

Weight (Silent) Kg 1890
Weight (Open) Kg 1650
Width (Silent) Mm 1000
Length (Silent) Mm 3150
Height (Silent) Mm 1700
Fuel Tank Capacity Lt 250

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Nov-10-22
 
EAP 110
Engine Model : 1104C-44TAG2
Stand By kVA: 110
Stand By kW : 88
Prime kVA: 100
Prime kW : 80
Rated Current : 144

Engine
heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed

- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis ground)

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine
Engine Model 1104C-44TAG2
Number of Cylinders 4 Inline
Injection System Direct
Compression Ratio 18,2 : 1
Bore 105
Strok 127
Displacement Lt 4,4
Air Intake Turbocharged - Air to Air Cooled
Speed (RPM) 1500
Oil Capacity Lt 8
Standby Power kw / Hp 80.7 / 109
Prime Power Hp 73.4 / 99
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 13
Fuel Consumption (lt / h) Lt Full Load 22
Lt %75 LOAD 16,9
Lt %50 LOAD 11,1

Frequency Hz
Power kVA 110
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8

Weight (Silent) Kg 1480
Weight (Open) Kg 1290
Width (Silent) Mm 1000
Length (Silent) Mm 2800
Height (Silent) Mm 1500
Fuel Tank Capacity Lt 210

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
3743 Others Suppliers
Short on time? Let Others sellers contact you.