PRODUCTS: Korean Red Ginseng Extract
Age Range (Description): 6 years
Diet Type: Plant Based
Material Feature: Natural
Stick-type, easy way to take Korean red ginseng
Ideal mix of 6-year-old Korean red ginseng and Korean traditional ingredients
Health functional food: boost immune systems, relieve fatigue, improve memory, increase blood flow and help antioxidant effects
Manufactured in reliable facilities: GMP, GAP
Tact Switch MT 1101 S is applied to low current circuit tactile switch for electronic equipment.The standard test conditions shall be 5 ~ 35 degree Celsius in temperature.
45 ~ 85% RH and 860 ~ 1060 m bar in atmospheric pressure.
Should any doubt arise in judgement, tests shall be conducted at 20±2 degree Celsius, 60±5% RH
Micro Switch action is PUSH-ON TYPE S.P.D.T
Contact resistance measurements shall be made with a 1KHz ± 200Hz max
DC 5V 1A contact resistance meter.
Insulation resistance measurements shall be made following application of DC 500 V potential across terminals and across terminals and frame for one minute.
The travel distance for the plunger to come to a stop shall be measured
Hook Switch is applied to low current circuit hook switch for electronic equipment.
The standard test conditions shall be 5~35 in temperature, 45~85% RH and 860~1060 m bar.
Storage temperature range : 30 degree Celsius to 80 degree Celsius, however 96 hours maximum for continuous storage over a range
Tact Switches MT 1102 VS is applied to low current circuit tactile switch for electronic equipment .Contact resistance measured DC 5 V 1 A or by ohmeter allowing a small current at 1 kHz with a load of twice of the Actuating force
Insulation resistance DC 100V is applied between terminals and between terminals and cover for 1 minute ± 5 seconds
77 Office Storage Systems Suppliers
Short on time? Let Office Storage Systems sellers contact you.
Tact Switches MT 1101 U is applied to low current circuit tactile switch for electronic equipment.
Contact resistance measured DC 5V 1A or by ohmeter allowing a small current at 1 kHz with
a load of twice of the Actuating force
Insulation resistance DC 100V is applied between terminals and between terminals and cover for 1 minute ± 5 seconds
Tact Switches MT 1102HT Contact resistance applying a static load twice the actuating force to the center of the stem, measurements shall be made with a 1kHz small-current contact resistance meter.
Insulation resistance Measurements shall be made following application of DC 100V Potential across terminals and frame for one minute
Snap-in type, can be mounted directly on PC board.
Some of output terminals can be also used as jumper leads, thus making circuit arrangement easy.
Available with anti-ESD ground terminal.
Although the recommended PC board thickness is 1.6mm, the models which can be mounted on PC boards of thickness 0.8 to 1mm are also available upon request.
Tact Switch MT 1101 SE is applied to low current circuit tactile switch for electronic equipment.
Storage temperature range 96 hours maximum for continuous storage over a range
The standard test conditions shall be 5 ~ 35 degree Celsius in temperature.
Snap-in type, can be mounted directly on PC board.
Some of output terminals can be also used as jumper leads, thus making circuit arrangement easy.
Available with anti-ESD ground terminal.
Although the recommended PC board thickness is 1.6mm, the models which can be mounted on PC boards of thickness 0.8 to 1mm are also available upon request.
Snap-in type, can be mounted directly on PC board.
Some of output terminals can be also used as jumper leads, thus making circuit arrangement easy.
Available with anti-ESD ground terminal.
Although the recommended PC board thickness is 1.6mm, the models which can be mounted on PC boards of thickness 0.8 to 1mm are also available upon request.
Tact Lever Switches is applied to low current circuit push switch for electronic equipment.
Appearance of the Switch shall have good finishing, and no rust, crack or plating failures.
Operating force of a static load shall be applied to the tip of actuator in operating direction.
Robustness of terminal of a static load of 2N(200gf) shall be applied to the tip of terminal
in a desired direction for 1min. the test shall be done once per terminal.
Tact Switch MT 1101 V Contact resistance applying a static load twice the actuating force to the center of the stem, measurements shall be made with a 1kHz small-current contact
resistance meter.
Insulation resistance measurements shall be made following application of DC 100V potential across terminals and frame for one minute.
Tact Switches MT 1101 Contact resistance applying a static load twice the actuating force to the center of the stem, measurements shall be made with a 1 kHz small-current contact
resistance meter.
Insulation resistance measurements shall be made following application of DC 100 V
Potential across terminals and frame for one minute
Detector Switches is applied to low current circuit (Secondary circuit) push switch
used for electronic equipment.
Appearance of the Switch shall have good finishing and shall have no rust, crack of plating failures.
Terminal Strength of a static load of 3N(306 gf) shall be applied to the tip of terminal in a desired direction for 1 minute. The number of test shall be once per terminal.
The enzymes whose major biological function is the synthesis of polymers of nucleic acids. DNA polymerase and RNA polymerase are used to assemble DNA and RNA molecules, respectively. They are the most important products for molecular diagnosis in these days.
The enzymes that cleave DNA at specific recognition nucleotide sequences known as restriction sites. These products are commonly used for constructing recombinant DNA for producing bio pharmaceutics.
The ready-to-use sets of our products assembled for a convenient use. We supply four different gene cloning kits and a number of different reverse transcription, PCR or real-time quantitative PCR kits.
77 Office Storage Systems Suppliers
Short on time? Let Office Storage Systems sellers contact you.