The AF Series 1-stack 3-pole contactors are of the block type design. Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available
UA16-30-10 RA UA26-30-10 AF9-30-10 AF1250-30-11
UA16-30-10 RA UA26-30-10 AF12-30-10 AF1350-30-11
UA16-30-10 RA UA26-30-10 AF16-30-10 AF1650-30-11
UA16-30-10 RA UA26-30-10 AF26-30-11 AF2050-30-11
UA26-30-10 RA UA30-30-10 AF30-30-11 AF2650-30-11
UA26-30-10 RA UA30-30-10 AF40-30-11 A9-30-11
UA26-30-10 RA UA30-30-10 AF50-30-11 A12-30-11
UA26-30-10 RA UA30-30-10 AF63-30-11 A16-30-11
UA30-30-10 RA UA50-30-00 AF75-30-11 A26-30-11
UA30-30-10 RA UA50-30-00 AF95-30-11 A30-30-11
UA30-30-10 RA UA50-30-00 AF110-30-11 A40-30-11
UA30-30-10 RA UA50-30-00 AF116-30-11 A50-30-11
UA50-30-00 RA UA63-30-00 AF140-30-11 A63-30-11
UA50-30-00 RA UA63-30-00 AF145-30-11 A75-30-11
UA50-30-00 RA UA63-30-00 AF146-30-11 A95-30-11
UA50-30-00 RA UA63-30-00 AF185-30-11 A110-30-11
UA63-30-00 RA UA75-30-00 AF205-30-11 A145-30-11
UA63-30-00 RA UA75-30-00 AF210-30-11 A185-30-11
UA63-30-00 RA UA75-30-00 AF260-30-11 A210-30-11
UA63-30-00 RA UA75-30-00 AF265-30-11 A260-30-11
UA75-30-00 RA UA95-30-11 AF300-30-11 A300-30-11
UA75-30-00 RA UA95-30-11 AF305-30-11 A320-30-11
UA75-30-00 RA UA95-30-11 AF370-30-11 AF460-30-11
UA75-30-00 RA UA95-30-11 AF400-30-11 AF580-30-11
UA110-30-11 UA110-30-11 UA110-30-11 AF750-30-11
UA110-30-11 UA110-30-11 UA110-30-11
This surge protective device( hereinafter referred to as SPD) are suitable for AC 50/60Hz, rated voltage up to 380v IT,TT,TN-C, TN-S,TN-C-S and other power supply system, it protect to indirect and direct lightning effect or other transient over voltage
SPD design according with GB18802.1/IEC61643-1 standard.
Specification details:
Model PQ1-60
Poles 4P
Max. continious working voltage(Uc) 420V AC(can customized)
Nominal discharge current(In) 30kA
Max.discharge current(In) 60kA
Voltage protection level(Up) 2.0kV
Matched circuit breaker/Fuse 32A
Response time
This surge protective device( hereinafter referred to as SPD) are suitable for AC 50/60Hz, rated voltage up to 380v IT,TT,TN-C, TN-S,TN-C-S and other power supply system, it protect to indirect and direct lightning effect or other transient over voltage
SPD design according with GB18802.1/IEC61643-1 standard.
Specification details:
Model PQ1-80
Poles 2P
Max. continious working voltage(Uc) 420V AC(can customized)
Nominal discharge current(In) 40kA
Max.discharge current(In) 80kA
Voltage protection level(Up) 2.5kV
Matched circuit breaker/Fuse 32A
Response time
Part NO Coil Voltage 50/60HzNumber of PolesFull Load (A)Maximum Voltage
25 FLA -2 Pole
QCA-25224225120
QCB-252120240
QCC-252208/240
30 FLA-2 Pole
QCA-30224230120
QCB-302120240
QCC-302208/240
40 FLA-2 Pole
QCA-40224240120
QCB-402120240
QCC-402208/240
GSC1 series AC Contactors are used in the circuit of 50Hz or 60Hz frequency with rated current up to 95A under usage category AC-3 at 380V AC. These AC contactors comply with IEC60947-4:
Rated Isolation Voltage: up to AC690V
Rated Voltage: 220V AC or 380V AC or 415V AC or 440V AC or 660V AC
Rated Current under usage category AC-3 at 380V AC (A) : 9A, 12A, 18A, 25A, 32A, 38A, 40A, 50A, 65A, 80A, 95A
Series ac contactor is suitable for using in the circuits up to the rated voltage 660v ac 50hz, rated current up to 95a, for making, breaking, frequently starting & controlling the ac motor. Combined with the auxiliary contact block, timer delay & machine-interlocking device etc, it becomes the delay conactor, mechanical interlocking contactor, star-delta starter. With the thermal relay, it is combined into the electromagnetic starter. The contactor is produced according to iec947-2, vde0660 & bd5452.
The contactor is suitable for using in the circuits up to the rated voltage 660v ac 50hz or 60hz, current 300a, for convertible controlling the motor. It's mechanical interlocking device ensures contact changeover of the two convertible contactor.
Our featured products automatic transfer switch, circuit breaker, contactor, pilot light,relay, SPD, etc. with solid quality and considerable price and could equip them with enclosure.
Application
CJX2 Series AC contactor is mainly applies to the circuit of AC 50Hz/60Hz, and rated insulation voltage 660V. When use in AC-3, and rated operational voltage is 380V, rated current up to 630A, for long distance breaking circuit and frequently starting or control the motor. Combined with proper thermal overload relay can protect load circuit. Contactor can frequently start and control AC electromotor.
Construction Features
1. Adopt build-in block system to mount auxiliary contractor block, air delay auxiliary contractor, thermal overload relay and so on, which can be combined into multiple derved series product.
2. Contactor has the advantage of Small volume, light, low consumption, long life and good safety.
3. Main contactor below 32A has 1N/C or 1N/O, there is 1N/C and 1N/O above 40A, Contactor can be assembled with F4, F8 auxiliary contact or time-delay block.
4. Contactor can not only use screw mounting, but also use 35mm(CJX2-09-95), 75mm (CJX2-40-95) and 2x35mm (CJX2-D115-170) international standard Din-rail mounting
Electromagnetic contactor (contactor) refers to an electrical appliance that uses the current flowing through the coil to generate a magnetic field in industrial electricity to close the contact so as to control the load. The contactor is composed of electromagnetic system (armature, stator core, electromagnetic coil), contact system (normally open contact and normally closed contact) and arc extinguishing device.
Structural composition
Electromagnetic contactor is mainly composed of transmission device (electromagnetic mechanism), contact device (actuator) and arc extinguishing device.
1. Electromagnetic mechanism
The electromagnetic mechanism includes three parts: moving core (armature), static core and electromagnetic coil. The electromagnetic coil is connected with current to generate electromagnetic suction and drive the contact to act.
Electromagnetic mechanism is one of the important parts of electromagnetic contactor. The electromagnetic mechanism is composed of coil, iron core (static iron core), armature (moving iron core), pole shoe, iron yoke and air gap. The coil and iron core in the electromagnetic mechanism do not move in the working state; The armature is movable.
The electromagnetic mechanism converts the electromagnetic energy generated by the electromagnetic coil into mechanical energy through the action state and action process of the armature and the corresponding mechanical mechanism to drive the contact to close or open, so as to realize the control purpose of the controlled circuit.
Contactors are divided into AC contactors (voltage AC) and DC contactors (voltage DC), which are used in power, power distribution and power consumption. Broadly speaking, contactor refers to an electrical appliance that uses the current flowing through the coil to generate a magnetic field and close the contact in order to control the load.
main features
The AC contactor uses the main contact to open and close the circuit and the auxiliary contact to turn on the control circuit.
The main contact is generally normally open contact, while the auxiliary contact often has two pairs of normally open contact and normally closed contact. Small contactors are often used as intermediate relays to cooperate with the main circuit.
The contact of AC contactor is made of silver tungsten alloy, which has good conductivity and high temperature ablation resistance.
The power of AC contactor action comes from the magnetic field generated by AC through the coil with iron core. The electromagnet core is composed of two "mountain" shaped young silicon steel sheets. One of the fixed iron core is sleeved with coil, and the working voltage can be selected. In order to stabilize the magnetic force, a short-circuit ring is added to the suction surface of the iron core. After the AC contactor loses power, it returns by spring.
The other half is a movable iron core, whose structure is the same as that of a fixed iron core, which is used to drive the closing and breaking of the main contact and auxiliary contact.
Description
CJ16(19) switch-over capacitor contactor is
the new type of components for electric
appliances, standard for 400V(50/60Hz) grid, 3P3W connection from 25A~95A. It is
developed and produced on the basis of the
introduced foreign technology of the same
kind.
The device is widely applied to low voltage
reactive power compensation device to
replace the subassembly composed of three
XD1 current-limiting reactors and CJ10
contactor, and it is also can be used in the
general control circuit to limit surge impact, protect capacitor and other electrical device
from over voltage damage.