Covid 19 antigen rapid test kit (nasal swab).
Covid Test Kit.
Covid 19 rapid test kits.
Covid 19 Rapid Antigen Test Kit.
Covid 19 Antigen Rapid Self Test.
Testing Kits Covid 19 .
Covid 19 Rapid Antigen Test Kit.
Boson Kits Covid.
Covid 19 Test Kits.
Covid 19 Rapid Antigen Test Kits.
SPECIFICATION 1. Test Functions: Blood glucose, Hemoglobin and cholesterol test system 2. Glucose Measuring Range: 20 ? 600 mg/dL(1.1 ? 33.3 mmol/L) 3.Hemoglobin Measuring Range: 6 ? 27 mg/dL(179 ? 1190 µmmol/L) 4. Cholesterol Measuring Range: 100 ? 400 mg/dL(2.5 ? 10.4 µmmol/L) 5. Memory: 200 memories for Glucose, 50 memories for Hemoglobin and 50 memories for Cholesterol 6. Test Time: 10 seconds for Glucose, 6 seconds for Hemoglobin and 150 seconds for Cholesterol 7. Operation Temperature: 14 ? 40 °C (57.4 - 104°F) 8. Operation Humidity: = 2.6 for Hemoglobin ; >= 15µl for Cholesterol 12. Sample Type: Capillary whole blood 13. Hematocrit Rage: 30 ? 55% 14. Power Supply: CR2032 x1 15. Battery Life: Approximately 1000 tests 16. Display: LCD display (35 x 45mm) 17. Dimension: 88 (H) x 64 (W) x 22 (D)mm 18. Weight: 59.5 g (without battery) 19. Technology Used: Electrode-based amperornetric and Amperornetric Enzyme Electrode 20. Time & Date Display 21. Glucose Average Result: 7 / 14 / 28 days 22. Power On & Off: Automatically 23. Strip Type: Siphonal Strip (Capillary Action) 24. Warranty : 2 Years Contents of ET-3211 1. Meter 2. User's Manual 3. Blood Glucose / Cholesterol / Hemoglovin Test Strips 4. Lancets 5. Puncturer (lancing Device) 6. Pouch 7. Battery 8. Check Strip Fasting Blood Glucose / Blood Sugar Levels Chart Normal 70 - 100 mg/dL Early Diabetes 101 - 125 mg/dL Diabetic > 126 mg/dL The Following Values are Expected Blood Glucose / Blood Sugar Levels for Non-Diabetics Upon Waking - Fasting 70 - 99 mg/dL After Meals 70 - 140 mg/dL The Following Values are Targets for Diabetics Before Meals 70 - 130 mg/dL 1 - 2 Hours after Starting a Meal < 180 mg/dL
Product name:POCT PCT/CRP/hsCRP Rapid Test Kit Specification: 10 pcs, 25 pcs, 50 pcs, 100 pcs/box, or customized Specimen: Whole blood/serum/plasma Type:Cassette MOQ: 10,000 PCS Specimen:Human serum/plasma/whole blood Corollary machine: POCT Analyzer blood diagnostic machine FA-LF100B 2.Application PCT: Sepsis Monitoring 20170121143136.png Sepsis Diagnosis 20170121143156.png (Note: The cut-off value 2.0ng/ml is for reference only. Clinical departments shall adjust according to patient's situation.) CRP/hsCRP - Differential diagnosis of virus infection and bacterial infection - CRP relating with cardiovascular disease (CVD) - Accurate early diagnosis in pregnant women with amniorrhexis premature delivery and ch hsCRP < 1.0 mg/L Cardiovascular disease risk: Low risk 1.0-3.0 mg/L Cardiovascular disease risk: Moderate risk Anti-inflammatory therapy is recommended. > 3.0 mg/L Cardiovascular disease risk: High risk Anti-inflammatory and antithrombotic therapy is recommended. CRP < 10 mg/L Less possibility of bacterial infection or bacterium are eradicated 10-25 mg/L Virus infection signal When course is short, bacterial infection is possible. Re-check after hours. 25-50 mg/L Virus/bacterial infection signal 50-100 mg/L Usually bacterial infection Virus infection is uncommon. > 100 mg/L Bacterial infection signal Less possibility of virus infection
CTnI One Step Troponin I Rapid Test Kit (Whole blood/serum/plasma) 1.Product description Introduction: Product name: CTnI One Step Troponin I Rapid Test Kit Specification: Lateral-flow Immunofluorescence Chromatographic Assay 10 pcs, 25 pcs, 50 pcs, 100 pcs/box, or customized Type: Cassette MOQ: 10,000 PCS Analytical Range: 1.0~50ng/ml (Whole Blood); 0.1~50ng/ml (Serum/Plasma) Specimen: Human serum/plasma/whole blood Manufacturer: Hangzhou Laihe Biotech Co., Ltd. Clinical significance 1. Diagnosis of various chest pain 2. Foundation of ACS diagnosis and risk stratification 3. Best markers for ACS prognosis 4. An aid in the diagnosis of myocardial infarction (injury) 5. Can improve clinical, economic and operational outcomes Principle Insert the sample cassette into Immunofluorescence Quantitative Analyzer. The detection system will scan the markers and bond zone to gain optical signals, and then analyze the signals to get the concentration of the tested sample. Storage Valid for 24 months under 4-30 °C with aluminum foil bag packing. Once opened, the cassette is valid for 1 hour. 2.Application Clinical Laboratory, ED, ICU, CCU, Respiratory Department, Cardiology Department, Pediatrics Department, Surgery Department, Hematology Department, etc.
Tumor Marker PSA Prostate Specific Antigen Semi-Quantitative Rapid Test Strip Device Rapid Test Diagnostic Kit Accurate Product name: PSA Prostate Specific Antigen Semi-quantitative Rapid Test Kit Specimen: Whole blood/serum/plasma Format: Strip/cassette Specification: 25pcs, 40pcs, or customized MOQ: 10,000 pcs Sensitivity: 4ng/mL, 10ng/mL Application: Specific antigen in prostate, help in diagnosis of early prostatic diseases.
We can provide various infectious diseases test kits as listed. Product name Cat. No. Specimen Packing Chlamydia Rapid Test Device ICH-502 Swab/urine Cassette: 10 or 40pcs/box or Customized HBsAg One Step Hepatitis B Surface Antigen Test Device IHBsg-302 Serum/plasma Cassette: 10 or 40pcs/box or Customized HBsAg Hepatitis B Surface Antigen Rapid Test Device IHBsg-402 Whole blood/serum/plasma Cassette: 10 or 40pcs/box or Customized HBsAg One Step Ultra Hepatitis B Surface Antigen Test Device IHBsg-302U Serum/plasma Cassette: 10 or 40pcs/box or Customized HCV Hepatitis C Virus Rapid Test Device IHC-302 Serum/plasma Cassette: 10 or 40pcs/box or Customized HCV Hepatitis C Virus Rapid Test Device IHC-402 Whole blood/serum/plasma Cassette: 10 or 40pcs/box or Customized HIV 1/2 Antibody Rapid Test Device IHI-402 Whole blood/serum/plasma Cassette: 10 or 40pcs/box or Customized H. Pylori Antigen Rapid Test Device IHPg-602 Feces Cassette: 10 or 40pcs/box or Customized H. Pylori Antibody Rapid Test Device IHPb-602 Serum/plasma Cassette: 10 or 40pcs/box or Customized Syphilis Ultra Rapid Test Device ISY-402U Whole blood/serum/plasma Cassette: 10 or 40pcs/box or Customized Dengue Fever Rapid Test Device IDE-402 Whole blood/serum/plasma Cassette: 10 or 40pcs/box or Customized Malaria P. f. /P. v. Rapid Test Device IMA-422 Whole blood Cassette: 10 or 40pcs/box or Customized
Product name: hCG One Step Pregnancy Test Kit,FSH One Step Menopause Rapid Test Kit ect. Specimen: Urine Format: Strip/cassette/midstream Specification: 25pcs, 40pcs, or customized MOQ: 10,000 pcs Accuracy: > 99% Storage: 4-30°C Valid for: 24 months
Product name: TORCH IgM Rapid Combo Test Device Format: Cassette Specimen: Whole blood/serum/plasma Test items: Toxo IgM, CMV IgM, Rubella IgM, HSV 1 IgM, and HSV 2 IgM Valid for: 24 months 2.Features -Customized sensitivity, printing color and packing -Accurate, quiet, stable, convenient -Latest production -Competitive quality and price -Easy payment and shipment
Flu A H5 subtype Antigen Rapid Test Kit/Flu A H7 subtype Antigen Rapid Test Kit/Flu A H9 subtype Antigen Rapid Test Kit. They're highly sensitive, high specificity, and it's easy to use. Because the company is manufacturer, we can offer better quality at reduced prices.
This rapid test kit is to detect p80 protein specific antibody of bvdv, which is accurate, sensitive and specific.
(1)The One Step Drug Screen Test Panel (Urine) is an immunoassay based on the principle of competitive binding.Drugs which may be present in the urine specimen compete against their respective drug conjugate for binding sites on their specific antibody. (2)During testing,a urine specimen migrates upward by capillary action. A drug, if present in the urine specimen below its cut-off concentration, will not saturate the binding sites of its specific antibody coated on the particles. The antibody coated particles will then be captured by the immobilized drug conjugate and a visible colored line will show up in the test line region of the specific drug strip. The colored line will not form in the test line region if the drug level is above its cut-off concentration because it will saturate all the binding sites of the antibody coated on the particles.