Please click here to check who's online and chat with them.

Find Verified Other Medical Equipments Suppliers, Manufacturers and Wholesalers

Jan-07-20
Supplier From Guangzhou, Guangdong, China
 
Instrution For Betalactam+Tetracycline Combo Test
Introduction
TwoSensor Kit, rapid to detect two types of antibiotics residues in milk and dairy products by using colloidal gold immunochromatography technology. As soon as 7-10 minutes to results.

Application
For raw milk, whole milk powder, Pasteurized milk.

Specifications
1. Specificity
Not cross-react with macrolides, trimethoprim, sulfonamides drugs, etc.

2. Limit of Detection
Refer to instruction.

Storage & Shelf-Life
At 2~8 out of sunlight, 12 months

Compolents (96T / box)
Instruction 1
Tube 12

Equipments (Option)
Timer
Incubator
Mini Pipette(200L)
Tips for mini pipette
Reader

Operations
1. Take 200 L milk specimen, add into micro well, mix with the pink agent 10 times.
Remark: avoid specimen residues too much in the well.
2. Incubate 3 minutes
3. Insert strips into the wells
4. Incubate 5 minutes
5. Take out strips and read results by eye or reader.
Jan-02-20
 
Repair Hitachi HI VISION Preirus RX Board CZH4AA


1. Part number: CZH4AA
2. Compatible with Hitachi HI VISION PreirusUltrasound
3. With 60 days warranty
4. Maintenance time: 2-4 days

Various GE/Philips/Siemens/Toshiba/Hitachi/Biosound ultrasonic boards are within our repair/maintenance range.
Jan-02-20
 
Repair Hitachi HI VISION Preirus TX1 7513629A


1. Part number: 7513629A
2. Compatible with Hitachi HI VISION Preirus Ultrasound
3. With 60 days warranty
4. Maintenance time: 2-4 days

Various GE/Philips/Siemens/Toshiba/Hitachi/Biosound ultrasonic boards are within our repair/maintenance range.
Jan-02-20
 
Repair Aloka F75 USP EP556600

1. Part number: EP556600
2. Compatible with Aloka F75 Ultrasound
3. With 60 days warranty
4. Maintenance time: 2-4 days

Various GE/Philips/Siemens/Toshiba/Hitachi/Biosound ultrasonic boards are within our repair/maintenance range.
Jan-02-20
 
Aloka mainboard for F75(P/N:EP558800AB)
1.Model: EP558800AB
2.Demo original one,like new, in excellent condition
3.We provide 60 days warranty

Note: We have most parts for F75 device in stock.
5280 Other Medical Equipments Suppliers
Short on time? Let Other Medical Equipments sellers contact you.
Jan-02-20
 
Repair Hitachi HI VISION Avius RDBF 7513907A


1. Part number: 7513907A
2. Compatible with Hitachi HI VISION Avius Ultrasound
3. With 60 days warranty
4. Maintenance time: 2-4 days

Various GE/Philips/Siemens/Toshiba/Hitachi/Biosound ultrasonic boards are within our repair/maintenance range.
Jan-02-20
 
Repair/Exchange Hitachi HI VISION Avius/Preirus Cell board 7345930A

Common error: transducers not detected

Repair time:2-4 days

Warranty after fixed:60 days

We provide exchange and repair for this board, feel free to contact for further information!
Oct-21-19
 
Manual hydraulic obstetric table
Model:JQ-2003
1/Table size L2200*W600mm
2/ Table height720mm-960mm
3/ Led board Removable
4/ lean forward angle 22
5/ lean backward angle 8
6/ Back board folded up 70
7/ Back board folded down 10

Features:
1/ The hydraulic examination table is mainly used for delivery and gynecologic surgeries.

2/ The tabletop lifting is controlled by hydraulic pump, all the actions can be adjusted and locked at any positions in its adjustment range.
Oct-21-19
 
double arm/single arm /ceiling mounted type and wall type and mobile type/Osram led bulbs/50000h lifetime/FOB shanghai/delivery time 7days/FDA CE ISO certificate search jaqimedical for more information/apply to hospital,clinic operating theatre
Oct-21-19
 
Illumination:140,000lux+160,000lux
1/ LED chips: Gemerany OSRAM
2.Color tempeture: 4000K-5000K
3.diameter spot: 150mm-300mm
4.light adjustable steps:10%-100%
5.Restore color index : 95
6.shadowless rate :98%
7.led using life :>50000h
8.work distance:500-2000mm
Oct-21-19
 
Model NoJQ-001
Light Spot Diameter110mm@400mm
Max Illumination15000lux@200mm
Brightness control4 levels
Battery indicationLighting Tips
Viewing AngleAny angle
Opertaing timeHighlight 6hrs,low light 24hrs
Color Temperature5700K-6500K
LED lifespan10000hrs
Battery Capacity(Li-ion polymer battery)Rechargeable and replaceable 2000Mah,3.7V
Apply to Dental,ENT,Vet,Plastic surgery ,ICU surgery, Operaiton,Clinic,Examination,ETC.
Oct-21-19
 
Infinite positioning of the legs.

Easily adjustable with pneumatic support

Knee crutch is adapted automatically when the leg position is adjusted.

One-hand operation.

Pressure relief of the calves thanks to soft padded insert.

Protects from positioning injury in the vicinity of the nervus peroneus.
Oct-21-19
 
CO2/Carbon Dioxide Absorbent Soda LimeTechnical Specifications

Component
Calcium Hydroxide :76%-83%
Sodium Hydroxide :29%
Co2 Absorption>140L/kg
Moisture Antivity
MOQ:500KG
Oct-21-19
 
Model No.:Orthopedic tractor/traction frame to match any kinds of electric operating table
stainless steel material
1/Table size ( mm) 1700*480*750mm
2/ Lifting range:250mm
Oct-21-19
 
1/Driven by imported Electric-Hydraulic system with advanced backup power,suitable for General surgeries

2/ The tabletop framework is molded aluminum casting. The base cover is made of 304 stainless steel

3/Could use with C-arm and X-ray

Model No:JQ-01B-1 electric hydraulic surgical table
1/Table size ( mm)L2000*W500*H750
2/ Table lifting height750mm-1050mm
3/ Lean forward22
4/ Lean backward25
5/ Lean left20
6/ Lean right20
7/ Back board folded down 35
8/ Head board folding up45
9/ Head board folding down90
10/ Leg board folding down90


11/ Lengthways slide range295mm
Oct-21-19
 
It is used in hospital,Pediatric clinic, emergency room, outpatient transfusion room, community medical
institutions, hospitals, emergency center, blood center, physical examination center, the CDC, the
rehabilitation center,the nursing homes and so on.
Oct-11-19
 
Summary
Intelligent control system with stable and high effective operation
Comprehensive ventilation and monitoring functions
Advanced fabrication process
Communication Interface
Used to connect with Hospital network and communicate with other medical equipment
Also used to upgrade equipment and upgrade port
Display
15 inch touchable screen with Day/Night display mode
Real-time detection for circle graph. airway pressure, flow rate. volume. compliance and air resistance
Electronic flowmeter with electronic gas mixing
Integrated Breathing Circuit
Integrated breathing circuit with APL valve, excellent tightness and easy to use
Low essential resistance, good mechanical compliance
Replacing drive bellow is not required when operating pediatric anesthesia
Drain cup design ensure no water trap in the breathing circuit
Built-in design duo flow sensor (no maintenance required)
2L large volume of CO2 canister
Autoclave 134
High-precision Vaporizer
Vaporizer can support low flow anesthesia (as low as 0.2L/min) and large flow anesthesia (up to 15L/min)
Accurate output of concentrations under varying conditions of pressure, flow and temperature
Support Selectatec mounting type and cagemount compatible
Agent type: Isoflurane, Enflurane, Halothane, Sevoflurane
Service Free
Fill-in type: pouring
AGSS
Made by aluminum alloy
High stength, light weight, never rust
Enchance the safety of the environment in which members of staff in close proximity with waste anesthesia gases and vapors (agents)work
Module plug in design
Plug in design available for monitoring SPO2, CO2, FIO2 and 5AA (anesthesia gases module)
ACGO
International standard design
To connect with T circuit or bain circuit for open-operation
Convenient for patients' oxygen inhalation and postoperative recovery
Yoke system
Allow back-up cylinder
3 gas sources support: O2, N2O, Air
Convenient for patients' oxygen inhalation and postoperative recovery
Oct-11-19
 
COZING-WS11C indications:

A, product efficacy

1. To purify the blood

2. The flow of blood

3. stroke and brain injury

Second, the product scope

1. Patients with cerebrovascular disease

2. The three tenors crowd

3. The healthy people

4. People with poor sleep

5. Rhinitis crowd

LLLT for Stroke and Brain Injury
In the first clinical trial, PBM(Pharmacy benefit management) was applied within 24 hours of a stroke and the study noted statistically significant improvements when administered at 18 hours post-stroke, over the entire surface of the head regardless of the type of stroke. Only one laser treatment was administered, and results were present 5 days later. At 90 days post-stroke, 70 percent of the patients treated with LLLT still showed a significantly successful outcome.


What is Low-level laser therapy (LLLT)?

Low-level laser therapy (LLLT), also known as photobiomodulation, is an emerging therapeutic approach in which cells or tissues are exposed to low-levels of red and near-IR light. Its experimental applications have broadened to include serious diseases such as heart attack,stroke, and spinal cord injury. LLLT may have beneficial effects in the acute treatment of TBI by increasing mitochondrial respiration, activating transcription factors, reducing key inflammatory mediators, inhibiting apoptosis (programmed cell death), stimulating angiogenesis, and increasing neurogenesis
A second clinical trial determined LLLT treatment to be effective for moderate to severe strokes, but not severe. The third clinical trial was inconclusive for any significant results. There is some evidence to suggest that the time between the occurrence of a stroke and initiation of the PBM treatment may be an important factor.


PBM is proving helpful in brain injury recovery in numerous studies. In experiments with mice. those treated with LLLT had significantly reduced neurological deficits, including smaller loss of cortical tissue, better mobility, less depression and anxiety, increased BDNF, and better learning and memory.

In one small study with humans having TBIs ranging from 10 months to 8 years old, application of red and near infrared light emitting diodes (LED) three times a week for 10 minutes over six weeks significantly improved executive function, verbal learning, free recall, sleep, and decreased PTSD symptoms.
Oct-11-19
 
Introduction:
Its surprising just how many of us suffer from chronic infections on a weekly or monthly basis. While some may write it off as a part of life, inflammatory issues like this are not normal and need to be treated.
Suffering from recurring infections puts the skin in a state of constant inflammation, and in this state the body forms scar tissue rather than healing with normal healthy tissue. This disrupts the function of a body part forever, which is a major problem in areas like the genitals.
Whatever and wherever on the body you might be prone to these issues, its likely that red light therapy has been studied.
Red Light Reduces Inflammation?
Redness, soreness, itchiness and pain are typically linked to infections, as the immune system tries to defend against the aggressive microorganisms. The stress of this interaction on the local tissue contributes towards increased inflammation, which contributes to fungal growth. Many prescriptions and creams used for treating infections contain anti-inflammatory compounds like hydrocortisone. These can help the body to deal with the stress, but some say this just masks the underlying problem.
FIG 1. Graph summarising the short term effects of low dose 630-780nm red light on inflammation.
Some studies on red light lead to the potential conclusion that it may actually help the body to deal with the metabolic causes of inflammation5, allowing cells to produce more ATP and CO2?through our normal respiration reaction. These products of respiration have a supposedly almost identical effect to anti-inflammatoryã??



What Is Red Light Therapy?

Red light therapy involves having low-power red light wavelengths emitted directly through the skin, although this process cannot be felt and isnt painful because it doesnt produce any heat. Red light can be absorbed into the skin to a depth of about eight to 10 millimeters, at which point it has positive effects on cellular energy and multiple nervous system and metabolic processes.
Oct-11-19
 
What's the 650nm low level cold laser therapy necklace treatment and prevention angina heart care device Treatment range?

It could treatment Angina, myocardial ischemia, coronary heart disease, cerebral insufficiency



Cardiovascular disease is the number one cause of death worldwide. It is broadly defined to include anything which adversely affects the heart or blood vessels. One-third of Americans have one or more forms of it. By one estimate, average human life expectancy would increase by seven years if it were eliminated.

Advantage:

Laser therapy regenerates tissue, stimulates biological function, reduces inflammation and alleviates pain. Implementing laser therapy in the treatment of cardiovascular disease offers the possibility of increasing the health and wellbeing of patients while reducing the costs and enhancing safety of medical care.
Working principle

1, Purify The blood: It adopts low level laser with the wavelength of 650nm for household use, through specific parts of irradiation and using light radiation of laser and wavelength relation to change the biological characteristics and peel off the fat layer and cholesterol wrapped in the red blood cells, to improve the activity of the enzyme and oxygen carrying capacity as well as the deformability of cells, reduce the concentration of middle molecules in the blood, improve the rheological properties and lower triglycerides and cholesterol .

2, Smooth the blood flow: lauches 650nm laser wave to help eliminate the thick,sticky,viscous conditions of the blood,soften blood vessels,improve microcirculation,soften cardiovascular and cerebrovascular,prevent cardio-cerebral-vascular from contraction.

3, Protect the brain and nourish the heart.

Function

The treatment has been shown to have anti-anginal, antihypertensive effects, to improve cardiac performance and myocardial contractility, and to increase myocardial, coronary and aerobic reserves. This clinicofunctional efficacy was accompanied by positive shifts in lipid metabolism, lipid peroxidation activity, antioxidant defense, hemocoagulation and microcirculation.
Laser treatment significantly lowered systolic, diastolic and mean arterial pressure. Moreover, diastolic arterial pressure did not elevate high at submaximal bicycle exercise. Total peripheral vascular resistance also decreased. A good hypotensive effect was achieved in 90.4 percent of cases.
5280 Other Medical Equipments Suppliers
Short on time? Let Other Medical Equipments sellers contact you.