The a-v foot pump imitates the natural physiological processes when people can not walk. Rapidly inflating the foot or hand pad in less than 0.4 seconds produces a high velocity surge of venous blood flow, improving venous return and arterial blood flow in the extremities. It has the model LBTK-M 1000 which has the functions as follows: 1. Deep vein thrombosis and pulmonary embolism prophylaxis 1) rapid increase venous blood velocity-eliminate stasis 2) resulting turbulent blood flow scours vein valve pockets 3) shearing forces on the vein wall release edrf which lubricates blood flow and make endothelium non-adherent. 4) nature, safe bionic treatment without rish of bleeding complications. 5) more than 17 years clinical experiences worldwide. 2. Rapid reduction of acute and chronic edema. 1) to shorten waiting time to operation for joint fracture. 2) reduction of pain after surgery or trauma 3) fewer skin integrity complication 4) decrease or release the lymph edema or varicosis 5) accelerate the vein ulcer healing. 3. Fast reduction of compartment pressure Eliminate the possibility of fasciotomy 4. Increase peripheral arterial blood flow 1) improve rest-abi and post exercise abi 2) increase microcirculatory blood flow 3) accelerate ischemia wound healing 4) improve the claudicant distance 5) release or decrease rest pain. 1 unit per carton
Technology introduction the domestic leading checkup technology in vitro. the advanced international heating treatment and no trauma in vitro medicine-guiding technology. the traditional application technology, such as medical acupuncture treatment, massage , scraping , hammer treatment , cupping treatment. laser superconducting treatment technology Application: The disease of digestive systemre covered physical ther apynervous systembreathing system and gynecology.Menoprostate diseaseprostate proliferationurine-left symptom. The packing of therapy instrument should use wooden material as packing box.The therapy instruments should not be transported under the circumstances of shock, severe vibration, overweight and humidity.
Compute servo control box temperature skin temperature control ,humidity control Seperately display set temperature real temperatre and humidity Noise inside less than 60 dB Temperature fluctuations in the rang of less thjan 0.5DEG C,the bed surface temperature error ¼1.5 Heating time (increase by 11¡æ )¡Ü45min Self-test alarm and acousto-optic prompt of over-heating,deviation, circulation, senor, power outage . Infinitely adjustable baby bed tilt Integral aluminum tank can be taken out for cleansing and disinfection Protecting rail Blue-ray therapeutic apparatus that keep warm and provide treatment for jaundice,which equipped with timer. 109*64*132(CUM) Gross Weight:108kg Net Weight:88kg.
Composition: Austin Moore femoral head non sterile 37mm to 55mm. Austin Moore Femoral Head gamma sterile 37mm to 55mm. Austin Moore long Stem non sterile 37mm to 55mm. Thompson femoral head non sterile 37mm to 55mm. Thompson femoral head gamma sterile 37mm to 55mm.
We manufacture locking head screws of different sizes using latest technology and high grade raw materials.It is used in the osteoporosis bone.Our quality product is highly appreciated by the surgeons. Technical Specifications 1.Locking head screw 3.5mm 10mm to 60mm 2.Locking head screw 5.0mm 10mm to 70mm 3.Locking head screw 6.5mm 25mm to 100mm.
Name of product : Disposable dental bibs Specification :material: two-ply or one-ply wood pulp paper and one-ply PE film laminated.Size: 33*45cmgross and net weight: 6.0 kg, 6.5kgcolor: white, blue, lavender, silver grey, yellow, green, dusty rose, beige, peach, aqua. Packing : 125pcs/bag;500pcs/ctn ;ctn size:34*24*25.
We are presenting a range of D.H.S Plates in superior XL quality DHS, HIP screws and Plates in round and DC Holes manufactured for use in orthopedic surgery. The dimensions and the specification are made as per the international quality standard. With DCP dynamic compression holes and slots for tension device Fixation with 4.5mm cortial screws. For pertochanteric and intertrochanteric fractures.
The Neuro Endoscopy System is used for minimal invasive surgery with only one hole. It is a very innovative product which reduces time and blood loss during a neurosurgery. You do not need to make two holes to realize an endoscopy anymore. With this system, only a minimal invasive surgery with one hole is sufficient because we provide one tool which has four different channels: - Optic - Aspiration/irrigation - Working - Light fibers For this endoscopy system, we offer a large range of scopes: - Neuroscope - Cranioscope - Haematoscope - Vertebroscope - Flex-neuroscope - Viewing dissector The special price is Rs.10 lacs (USD 19000) instead of Rs.13 lacs for: - 1 scope - 1 chip camera - 1 light source Xenon 100 watt - 4 operating instruments - Cables However, if you wish three chip camera instead of one chip, it is Rs.12 lacs (USD 21630) and if you wish a complete set, it is Rs.30 lacs (USD 54060) i.e: - 3 scopes - 3 chip camera or HD - 10 instruments - Cables - 100 or 300 watt Xenon light source.
State of the art overhead / ceiling lift solutions for safe patient transfer.
0.5µl of blood 5 seconds measuring 300 memories 20 ~ 600 mg/dL ( 1.11 ~ 33.33 mmol/L) of measuring range 3V lithium Battery type Standard Set Blood glucose meter 10 pcs Strips & 10 pcs neddles Out color paper box Carrying bag.
* The introducer sheath kit is used to establish channel for the other devices in PTCA procedure, PCI Procedure and angioplasty procedures. * Smooth transition between dilator and sheath; * Well tapered dilator tip; * Slippery sheath and dilator surface; * Precise hemostasis valve design; * The kit includes: 1pcs introducer sheath, 1pcs dilator, 1pcs 0.038in*45cm guide wire, 1pcs 18G*7cm angiographic needle. Individual tyvek-blister package.
Features: • Calculiclast is most effective equipment for urinary stone fragmentation of any size. • It can fragment renal, bladder or ureter stones with the help of different probes. • It has adjustable power of the blast. • Four different preset frequencies for different applications. • Its handtool is light-weight & easy to assemble. • The complete unit is portable & comes in specially designed PVC molded bag. 1 Bag consisting of • Control Unit • Hand pieces : 2 Nos. • Silicon Rubber Tubing • Footswitch • Oxygen Gas Regulator • PU-6 Tubing • Probes-0.8 mm, 1 mm, 1.2 mm each for ureteric stones, 1.5 mm, 2 mm each for bladder & renal stones. • One PVC molded bag with foam lining inside to accommodate all the parts of Calculiclast.
Features: High performance microprocessor with dot matrix printer. Designed to streamline diagnostic uroflow recording. Measures & indicates urinary flow rate in ml/sec. Based on load cell technology which gives superior accuracy. System consists of Regular : Uroflow Transducer, Control Unit, Beaker. Optional : Chair, DotMatrix Printer. Flowcomp with computer Features: • Online presentation and monitoring of test through specially developed Operating Software. • Windows XP based operating software with facility for data storage & retrieval.
Models • Urocomp 2000 Uroflow + Cystometry • Urocomp 2000E Uroflow + Cystometry + Emg • Urocomp 2000U Uroflow + Cystometry + UPP • Urocomp 2000 EU uroflow + cystometry + EMG + UPP + Video + Gynaecology study. 1 number.
62.7550 Fomon Rasp 8 1/2" coarse convex/flat 8mm This is a top of the line, professional stainless steel instrument. 8 1/2" coarse convex/flat 8mm.
62.1710 Joseph Rasp 6 1/4" cross serr fine This is a top of the line, professional German stainless steel instrument. 6 1/4" cross serr fine.
This is a top of the line, professional German stainless steel instrument.
62.1720 Lewis Rasp 7 1/2" fine This is a top of the line, professional German stainless steel instrument.
ARIES 2500 Anesthesia Machine: Display: 10.4 TFT color screen Application: Adult, Pediatric Driven mode: Pneumatically driven electronically controlled Mode: Semi~open, Semi~closed or closed system Anesthetic vaporizer: two high precise vaporizers Power supply: 220V,10%, 50Hz,1Hz 10V,10%, 60Hz,1Hz Internal battery: DC12V (4 working hours) Fresh gas outlet is in front of frame Anesthesia Ventilator: Respiration mode: IPPV, VCV, PCV, SIMV, SIGH, MANUAL, STANDBY, DEMO Waveform: P-t, F-t, V-t, F-v, V-p Tidal Volume: 20~1600ml Respiratory frequency: 1~65bpm I:E ratio: 4:1~1:4 Inspiration pause: 0~55%Ti Inspiration Pressure: 1~60cmH2O Trigger Pressure: -20~20cmH2O Monitoring parameters: O2 concentration, MV, Respiratory frequency, Tidal volume, Ppeak, PEEP, I:E ratio, Pmean, Compliance etc.. Alarm parameters: high pressure alarm, low pressure alarm, O2 concentration alarm, MV alarm, O2 source failure alarm, AC power failure alarm, etc. Pressure alarm setting: High pressure alarm set 1~60cmH2O. Low pressure alarm set 0~20cmH2O O2 concentration alarm setting: high: 21~99%. Low: 21~50%. MV alarm setting: MV high alarm set 10~99L/min MV low alarm set 0~40L/min Main Unit: Circle absorber: Compact circle absorber Flow meter: Five~tube flow meter O2 tube: 0L/min~1L/min~10L/min. N2O tube: 0L/min~1L/min~10L/min. Air tube: 0L/min~10L/min O2 and N2O Linkage Device, keep oxygen concentration not lower than 25% Oxygen flush: 25L/min~75L/min Gas source pressure: O2: 0.25Mpa~0.65MPa N2O: 0.25Mpa~0.65MPa Air: 0.25Mpa~0.65MPa Gauge: 4 units, 2¡ÁO2£¬N2O, Air.
Special Feature: Ventilation method: Closed, half-closed, half-open Small and compact unit ideal for office based anesthesia Two-gas machine( N2O&O2 ) Mechanical Anti-Hypoxic Device and O2/N2O interlock External CO2 circle absorber system Vetilator (option): TH-1, TH-1 A Main Unit: Tidal volume( Manual Mode): 20 ~ 1500ml Gas pressure: 0.25 ~ 0.65Mpa Flowmeter: O2 :0.1 ~ 10L/min N2O:0.1 ~ 10L/min APL valve: 0.5 ~ 6.0Kpa O2 Flush: 25 ~ 75L/min Ventilator TH-1 Special Feature: Driven mode: Pneumatically driven electronically controlled Display: High light LED display Ventilation mode: IPPV and Manual mode Tidal volume: 50 ~ 1500ml Breath frequency: 1~ 90Bpm I:E ratio: 4:1 ~ 1:6 Monitor parameter: Tidal volume, breath frequency, MV, airway pressure Alarm: MV high alarm£¬MV low alarm, TV high alarm, TV low alarm Ventilator TH-1(A): Special Feature: Respiration mode: IPPV, SIMV, MAUAL Display: 5.5¡¯ SNT screen Waveform: P-t, V-t Tidal volume: 50 ~ 1600ml Breath frequency: 1~ 65Bpm I:E ratio: 8:1 ~ 1:8 Alarm parameters: High pressure alarm, Low pressure alarm High pressure alarm limit: 20 ~ 60cmH2O Low pressure alarm limit: 0 ~ 20cmH2O Monitor parameter: Tidal volume, MV, Ppeak, PEEP, respiratory frequency, I:E ratio Safety valve pressure limit: 6Kpa Good air tightness, high reliability, and minor respiration impedance.