Covidien ABSTACK30 Absorbatack Fixation Device Part # ABSTACK30 Exp 3/19 Covidien ABSTACK30 Absorbatack Fixation Device is an absorbable tack fixation device, for use in laparoscopic hernia repair. The NEW AbsorbaTack (ABSTACK30X) fixation device for laparoscopic hernia repair continues to deploy tacks when the shaft is flexed over 3 cm. Covidien ABSTACK30 Absorbatack Fixation Device Features Designed with patient comfort in mind No metal required for fixation Supports a minimally invasive approach through 5 mm shaft and easy-to-use design Fixation strength Provides strong temporary mesh fixation, with retention strength comparable to the â??gold standardâ?? ProTackâ?¢ fixation device at 1 week and 2 months in an animal model1 Peace of mind Reduces the likelihood of inadvertent needle sticks in the OR, since no sharp piloting needles are required for deployment Potentially fewer visceral attachments than permanent tack fixation1 Violet tack with black-dot visualization feature to optimize visibility In Perfect sealed condition but past expiration date. Not for human use in the US. Expiration dates have mostly to do with sterilization and not the integrity of the product. The manufacturers sterilize the products after they are packaged and it lasts so many years. The only products we caution customers about are ones that are absorbable or drug coated.
Hand function position fixed splint (AJY-S09) It is used for the fixation of stable fractures of the hand and wrist, the fixation of neuromuscular and tendon injuries, and the fixation of functional positions after orthopaedic surgery. Prevent deformity caused by bone and joint disease in thumb-to-finger and palm-to-hand positions shape. 337*170*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Hand rest position fixed splint (AJY-S08) It is used for fixation after orthopedic surgery such as hand and wrist fractures, nerve tendon injuries, scar contractures, etc., to prevent or correct the deformities caused by bone and joint, neuromuscular disease. 360*210*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Thumb-fixed splint (Herringbone) AJY-S02 It is used for thumb metacarpal bone, acute metacarpal arthritis, thumb sprain, rheumatoid arthritis, post-tiger occidental occidental surgery and thumb function fixation after median nerve injury. 200*165*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Elbow Joint Splint (AJY-S12) It is used for elbow joint fixation for tendon, soft tissue, and nerve injury in the elbow joint in time for postoperative fixation of the joint. 448*260*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Achilles tendon dorsal splint (AJY-S11) It is used for dorsal fixation after Achilles tendon injury, topological fixation of supporting foot. 442*247*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Wrist Splint (Tubular Type) AJY-S07 For wrist or distal forearm fractures, functional fixation of wrist arthroplasty, and rest for wrist arthritis and other lesions Position immobilization or lunate dislocation colles fracture fixation. 300*280*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Thumb plate (tubular type) AJY-S03 For the first metacarpophalangeal joint, thumb phalanx, metacarpal fracture and wrist dislocation fixation. 210*145*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Our 3-Way Latex Foley Catheter is an advanced medical device designed for effective urinary drainage and post-operative bladder irrigation. This catheter features three lumens: one for inflating the balloon, which securely anchors the catheter in the bladder, another for continuous urine drainage, and a third for sterile irrigation. Constructed from high-quality latex, it prioritizes patient comfort and biocompatibility. The rounded, atraumatic tip eases insertion, while the reinforced eyes ensure unobstructed urine flow. Its balloon inflation valve prevents accidental deflation. With a range of sizes available, our 3-Way Latex Foley Catheter adheres to rigorous medical standards, making it the preferred choice for healthcare professionals seeking dependable urinary catheterization and irrigation solutions.
Our 2-Way Latex Foley Catheter is a medical device engineered for efficient urinary drainage and patient comfort. Crafted with precision, it features two lumens: one for inflating the balloon, which holds the catheter securely in the bladder, and the other for continuous urine drainage. Made from high-quality latex, it ensures biocompatibility and flexibility for patient comfort. The soft, rounded tip eases insertion, while the reinforced eyes facilitate smooth urine flow. Its secure balloon inflation valve prevents accidental deflation. Available in various sizes, our 2-Way Latex Foley Catheter meets stringent medical standards, making it a trusted choice for healthcare professionals seeking reliable and comfortable urinary catheterization solutions.
I can provide some general information about guiding catheters and Medtronic's involvement in the medical device industry. Guiding Catheter: A guiding catheter is a medical device used in interventional cardiology and radiology procedures. It is designed to guide and support other devices, such as guidewires and balloons, to the target location within the blood vessels. Medtronic: Medtronic is a global healthcare company that produces a wide range of medical devices and technologies. They are involved in various medical specialties, including cardiology, neurology, diabetes, and more.
Terumo Runthrough NS PTCA is a medical device designed for use in percutaneous transluminal coronary angioplasty (PTCA) procedures. PTCA is a minimally invasive procedure used to treat coronary artery disease by widening narrowed or blocked coronary arteries. Here are some key points about the Terumo Runthrough NS PTCA: Manufacturer: Terumo Corporation is a Japanese company known for its medical devices and healthcare products. Type: The Runthrough NS PTCA is a guide wire used in PTCA procedures. Guide wires are essential tools that help navigate catheters and other interventional devices through blood vessels during angioplasty. Function: The guide wire assists in guiding and positioning the catheter within the coronary arteries. It helps the interventional cardiologist navigate through the blood vessels and reach the site of the blockage or narrowing. Features: The "NS" in Runthrough NS may refer to "non-support" or "normal support," indicating the level of support provided by the guide wire. The choice of guide wire depends on factors such as the location and severity of the arterial blockage. Usage: The Terumo Runthrough NS PTCA guide wire is specifically designed for use in PTCA procedures to help facilitate the placement of angioplasty balloons and stents.
Volcano Corporation, a subsidiary of Philips, is known for its products in the field of intravascular imaging, including intravascular ultrasound (IVUS) systems. Here's a breakdown of the provided information: Volcano Visions PV .014P RX: This suggests a product or catheter associated with intravascular imaging, and the ".014P RX" could be indicative of the size or type of catheter. Digital IVUS: Intravascular ultrasound (IVUS) is a medical imaging technique used to visualize the interior of blood vessels. The term "Digital IVUS" indicates the use of digital technology in the imaging process. 150CM: This likely refers to the length of the catheter. Catheter lengths are often specified in centimeters.
it's common for medical device companies like Medtronic to manufacture guiding catheters used in various interventional procedures, including cardiovascular interventions. Guiding catheters are medical devices used to guide and support the delivery of other interventional devices, such as angioplasty balloons, stents, or embolic protection devices, during procedures like angiography and angioplasty.
Mowell Central Venous Single Lumen Catheter 16G X 6.29 Product Code: MW-LUMEN-01 Specifications: Guide wire Marked : 032"(.81mm) dia "J" Tip (Y-Shape) introducer Needle : 18G X70mm | Fastener Catheter clamp Normal Syringe 5ml | Dilator : 6.5F X 10cm | Catheter : clamp Injection cap | injection needle | Scaple # 11 Size/Strength: SIZE : Single , Double and Triple Single Lumen Central Venous Catheter Set Centrally inserted, single lumen central venous catheter. For administration of hyperosmolar solutions, measuring CVP, hemodialysis, plasmapheresis, rapid infusion of fluid among other uses. Mowell provides the benefit of polyurethane catheter which is soft, kink resistant, extremely biocompatible with excellent wear properties and elastic memory.
Thoracic Trocar Catheter Product Code: MED 133 Specifications: Sterile, individually packed in peelable blister pack Size/Strength: 8-16(230mm), 20-36(390mm) Description Manufactured from non toxic, medical grade PVC compound. Catheter is snuggly fixed over the trocar. Smooth taper shape Tip. Catheter is provided with large smooth eyes for efficient drainage. Catheter is marked at 5, 10, 15 and 20cm from the distal end to find out the depth of placement. Proximal end of the catheter is fitted with Taper shape connecter for easy connection to drainage Bottle/bag.
Umbilical Catheter Product Code: MED 153 Specifications: Sterile, individually packed in peelable pouch pack Size/Strength: 4, ,5, 6, 8, 10 FG (length 35 cm) Description Manufactured from nontoxic, medical grade PVC. Smooth round tip for non-traumatic insertion and well finished surface facilitates smooth passage of catheter in the vein. Radio opaque line provided throughout the tube for checking the position of the catheter radiologically. Marking is provided at every cm to ascertain depth of insertion. Proximal end of catheter is provided with Luer Female
I.V. Catheter for Paediatric/Neonates Use Product Code: MED 160 Specifications: Sterile, individually packed in peelable blister pack Size/Strength: 24FG, 26FG Description Siliconised stainless steel back cut needle for easy and painless vein puncture. Tapered tip for smooth and painless venipuncture. It allows quick visualization of flash back of blood and confirmation of catheter placement in vessel. It provides easy gripping and allowing more secure fixation to prevent accidental damage to needle or catheter.