Pipette Tips are consumables commonly used in chemistry,biology,medicine to transport a measured volume of liquid.It has many types and specifications,transparent or black,with or without filter,max volume can be from 10ul to 1250ul. We produce the pipette tips in 100,000 grade cleaning room.So the tips we have are DNAse, RNAse free and sterilized.
3-part blood cell counter
20 parameters + 3
histograms
2 counting channels
Up to 60 samples/hour
10.4â?³ large color LCD
Built-in printer, USB port
Stable, durable and
economical
Feature:
7 inch Color LCD , Touch screen
Flow cell and Cuvette test mode compatible
Real time curve showing
7 wavelength , 90 test item pre-programmed
Memory for 10,000 sample results
Light source hibernate function making lamp life longer
RS232 interface, PC connecting
Test mode: Kinetic, End point, Two point, Absorbance
Clear, Transparent & Flexible built in air vent Chamber.
Super smooth kink resistance tube.
Very Efficient roller controller for accurate flow rate.
Latex / Latex Free Tube for flushing.
Needle size G: 18.
Sterile / Disposable / Individual Packed.
Rochon polarizer is made of two birefringent material prisms cemented or optically contacted together. The Rochon prism was invented by and is named after Abb Alexis Marie Rochon. It is in many ways similar to the Wollaston prism, but the ordinary ray passes through the prism undeviated. Any separation angle can be designed according to request of customers.
Features
Multiple Polarization Materials Available
Ordinary Rays Pass Through Undeviated
Extraordinary Rays Deviate
Glan Taylor polarizer is made of two birefringent prisms that are assembled with an air space.
The polarizer with no side escape windows is suitable for low to medium power application where the side rejected beams are not required.
Photonchina Featureï¼?
Air-spaced
Close to Brewster's Angle Cutting
High Polarization Purity
Short Length
Wide Wavelength Range
Suitable for low to medium power application
Product Introduction
WFLC-VI Portable Waveform Recorder is a portable device based on the structure of an industrial portable computer. It takes high-performance DSP high-precision ADC chip and embedded operating system as hardware and software architecture and integrates data acquisition processing transmission storage analysis and other functions as one.
DSP acquisition chip for data acquisition and calculation so as to achieve full digital analog signal filtering flexible and diverse sampling frequency from 10K /s 20K /s 50k/s 100K /s can be selected by users can be used for transient electrical signal waveform recording and analysis.
With advanced industrial control kernel and embedded operating system users can easily carry out data storage backup analysis output and other operationsã??
WFLC-VI portable waveform recorder is a collection of fault wave record generator characteristic test and other functions in the integration of intelligent instrument with its small size strong function scope of application is wide flexible configuration and many other advantages favored by the masses of users is a power utility workers standing it will be for the electric power industry production and technological progress to make due contributions.
Compact Ram Presses : Ross & Mount
Lab presses provide precise , durable and cost effective performance. This Bench
top platen type press is used in sample compression moulding , punching / stenciling
, adhesive testing and sheet production . The linear Bearing units on hard chrome plated grounded steel shafts control the platen movements . This provide excellent durability . Tooling can be customized to suit the customer specifications . The day lights can be manually adjustable to suit the optimum operation of the press . Manual Stoppers can be
provided to adjust the variable stroke /Day light . The massive platens offers minimum deflections even at full loads .Built into a compact and elegant structure made of steel, treated with epoxy paint.
SPECIFICATIONS: LP-500
Platen size : 400 x 400 mm
Opening Stroke : 300 mm
Max. Clamping force: 50 tonnes
Max. Pressure : 180 Bars
Hydraulic pump : Piston type
Electric Motor : 3 KW
Minimum Day light : 150 mm
Max. Day Light : 300 mm
Dimensions : 1700(L) X 1200 (W) x 1800 (H)
TKDL-II live cable identification instrument is used to identify A particular cable in the power cable setting migration maintenance and fault treatment to identify A cable in the cable. It has the characteristics of accurate fast simple operation and wide application. It is an indispensable testing instrument in cable construction and maintenance. The electric/uncharged cable recognition device USES single-chip microcomputer technology to encode and power the transmitting signal at the transmitting end which drives the large calibre calipers to coupling the signal to the live cable. The single chip in the receiver decodes and phase the received phase encoding signal. The target cable is identified from a large bundle of other cables based on the uniqueness of the signal phase characteristics on the target cable. It is a light compact compact lithium battery powered portable instrument. Suitable for all kinds of high and low voltage power cables.
1. Charged identification and un-charged identification function combined not only for identification and judgment of cable outage but also for the identification and judgment of live cables the operation is extremely simple very easy to use.
2. The instrument lithium battery-powered you can work continuously for 3 to 5 hours suitable for field use of passive field.
PFA gas wash bottles
Gas wash bottles
PFA fluoroplastic labware for reliable analytical results
Gas-wash bottles are used, as the name suggests, for washing gases. The gas-wash bottle is connected to a gas flow and filled with a liquid, depending on. The gas is introduced into the liquid via a tube and is thus cleaned of contamination. Depending on the selected liquid a humidification (with water), drying (with concentrated sulphuric acid) or a targeted separation can take place.The purified gas is evacuated via a second tube from the gas-wash bottle.
Specification:100/250/500/1000ml
It is an economical device for precipitation material from gas, with porosity dispersion disk, FEP stopper has inlet and outlet ports for gas
Products Description
Product Name:
PFA gas wash bottles
Color:
Translucent
Size:
100/250/500/1000ml
Temperature resistance:
-200~+260
Characteristic:
1. break resistant
2. inert to virtyally all chemicals
3. excellent for long term storage
4. no leachable metals
5. excellent temperature stability
6.non-stick, easy to clean
7.factory with competitive price
8.MOQ is one ,some items are in stock, can dispatch timely
MOQ:
1pc
PFA gas wash bottles
Gas wash bottles
PFA fluoroplastic labware for reliable analytical results
Gas-wash bottles are used, as the name suggests, for washing gases. The gas-wash bottle is connected to a gas flow and filled with a liquid, depending on. The gas is introduced into the liquid via a tube and is thus cleaned of contamination. Depending on the selected liquid a humidification (with water), drying (with concentrated sulphuric acid) or a targeted separation can take place.The purified gas is evacuated via a second tube from the gas-wash bottle.
Specification:100/250/500/1000ml
It is an economical device for precipitation material from gas, with porosity dispersion disk, FEP stopper has inlet and outlet ports for gas
Products Description
Product Name:
PFA gas wash bottles
Color:
Translucent
Size:
100/250/500/1000ml
Temperature resistance:
-200~+260
Characteristic:
1. break resistant
2. inert to virtyally all chemicals
3. excellent for long term storage
4. no leachable metals
5. excellent temperature stability
6.non-stick, easy to clean
7.factory with competitive price
8.MOQ is one ,some items are in stock, can dispatch timely
MOQ:
1pc
Volumetric Flask, 1000mL. These volumetric flasks are highly-transparent, easy-to-clean, and meet Class A tolerances per DIN EN ISO 1042.Flasks are manufactured from virgin PFA , which is highly resistant to heat and chemical contamination. PFA surface properties offer superior cleanability to glass, PTFE and polypropylene containers, reducing risk of sample carryover in trace analysis applications. These beakers are suitable for sterilization using heat, gas, and chemical methods for sensitive biological applications. Screw cap design provides reduced contamination risk, compared to traditional stopper design.
Volumetric Flask, 250mL. Flasks are manufactured from virgin FEP , which is highly resistant to heat and chemical contamination. FEP surface properties offer superior cleanability to glass, PTFE and polypropylene containers, reducing risk of sample carryover in trace analysis applications. These beakers are suitable for sterilization using heat, gas, and chemical methods for sensitive biological applications. Screw cap design provides reduced contamination risk, compared to traditional stopper design.
OEM is available, welcome to contact for further details.
Volumetric Flask, 100mL. Flasks are manufactured from virgin FEP , which is highly resistant to heat and chemical contamination. FEP surface properties offer superior cleanability to glass, PTFE and polypropylene containers, reducing risk of sample carryover in trace analysis applications. These beakers are suitable for sterilization using heat, gas, and chemical methods for sensitive biological applications. Screw cap design provides reduced contamination risk, compared to traditional stopper design.
Uses
Sample baking, drying and sample digestion test, is a necessary tool for geological, metallurgical, environmental protection, agriculture, grain and cooking oil, forestry, food, medical and health, biochemical and other laboratories, as well as teaching and research. Sample digestion before chemical analysis of soil, feed, plants, seeds, heavy metals, ore. It is an ideal equipment of sample pretreatment for analytical instruments such as AA, ICP, ICP-MS, and atomic fluorescence. It can also be used for pretreatment and acid removal treatment of microwave digestion.
Main features
1.Corrosion resistance: Resist all kinds of acids: sulfuric acid, hydrochloric acid, nitric acid, hydrofluoric acid, perchloric acid, aqua regia and so on. Resist Alkali and a variety of corrosive gases.
2.High temperature resistance: Max. temperature 350 . (Plate temperature)
3.Temperature uniformity: The temperature difference of each point on the surface doesnt exceed 2 C. Homogeneous batches of specimens (dozens of beakers) can reach boiling point at the same time.
4.Temperature control accurate: Can adjust temperature as desired, PID adjustment, temperature control accuracy: 0.1C.
5.Fast temperature rising: the time for room temperature rising to Max. temperature doesnt exceed 40 minutes, and the mean value is 6.9 seconds/C.
6. No pollution: The plate hardness: Vickers hardness 20, density 3.02, no scratches, no dropping slags.
7. Temperature measuring by the plate: The temperature displayed by the instrument is actual temperature of the plate surface (operating temperature).
8. Two heat zones: The Max. temperature of A main heating zone is 350C , and Max. temperature of B secondary heating zone is 210C .
9. Shell material: High-quality ABS plastic wrap angle.
10. Reuse: The undamaged plate system can be reused.
11. Safety of use: Multilayer insulation protection, in case of equipment failure, the alarm will be light and sound and stop work immediately.
Uses
Sample baking, drying and sample digestion test, is a necessary tool for geological, metallurgical, environmental protection, agriculture, grain and cooking oil, forestry, food, medical and health, biochemical and other laboratories, as well as teaching and research. Sample digestion before chemical analysis of soil, feed, plants, seeds, heavy metals, ore. It is an ideal equipment of sample pretreatment for analytical instruments such as AA, ICP, ICP-MS, and atomic fluorescence. It can also be used for preparation and acid steaming treatment of microwave digestion.
Main features
1.Corrosion resistance: Resist all kinds of acids: sulfuric acid, hydrochloric acid, nitric acid, hydrofluoric acid, perchloric acid, aqua regia and so on. Resist Alkali and a variety of corrosive gases.
2.High temperature resistance: Max. temperature 350 . (Plate temperature)
3.Temperature uniformity: The temperature difference of each point on the surface doesnt exceed 5 C. Homogeneous batches of specimens (dozens of beakers) can reach boiling point at the same time.
4.Temperature control accurate: Can adjust temperature as desired, PID adjustment, temperature control accuracy: 0.1C.
5.Fast temperature rising: the time for room temperature rising to Max. temperature doesnt exceed 40 minutes, and the mean value is 6.9 seconds/C.
6. No pollution: The plate hardness: Vickers hardness 20, density 3.02, no scratches, no dropping slags.
7. Temperature measuring by the plate: The temperature displayed by the instrument is actual temperature of the plate surface (operating temperature).
8. Two heat zones: The Max. temperature of A main heating zone is 350C , and Max. temperature of B secondary heating zone is 210C .
9. Shell material: Metal coates high-quality ABS plastic.
10. Reuse: The undamaged plate system can be reused.
11. Safety of use: Multilayer insulation protection, in case of equipment failure, the alarm will be light and sound and stop work immediately.
4348 Laboratory Equipments Instruments Suppliers
Short on time? Let Laboratory Equipments Instruments sellers contact you.