Dairy equipment like cream separator, laboratory equipment and chemical.Export
Laparoscopic medical instruments and high precision components .Manufacture
Laboratory and hospital supplies and machines.
Used Laboratory Equipment New Electrical Heated Steam Generators.
PRP tube, PRP kit, platelet rich plasma, PRP centrifuge.OEM & ODM
Medical equipment like hospital beds, surgical tables, disposables, ultrasound machines and lab equipment.
Microscope, rotary evaporator, digi block, water chiller, auto clave, centrifuge, desiccator, chamber, fumehoods, shakers, spectrophotometers.
Product Features 1. PFA material (translucent) 2. High and low temperature resistance: -200 C to 260 C 3. Strong acid and alkali resistance, high temperature resistance, wear resistance, antistatic 4. No dissolution and precipitation, no contamination of samples 5. Also known as impact bottle, impact filter, purge bottle, buffer bottle, gas washing bottle product specification 90 degrees horizontal and vertical: 30ml/60ml (slender); 2 vertical PTFE threads: 60ml (slender)/60ml (big mouth)/90ml (big mouth)/120ml/150ml/180ml; 2 vertical ports PFA welding: 60ml (slender)/60ml (big mouth)/90ml (big mouth)/120ml/150ml/180ml; customizable.
Product Features: 1. PFA material (translucent) 2. High and low temperature resistance: -200 C to 260 C 3. Strong acid and alkali resistance, high temperature resistance, wear resistance, antistatic 4. No dissolution and precipitation, no contamination of samples Product Specifications: Two-way/three-way customizable
Product Usage: Wash away the impurities in the gas, and absorb the impure gas through the selected suitable liquid medium, so as to wash away the impurities and achieve the purpose of purifying the gas. Applicable industries: Isotope industry, heavy metal industry, semiconductor, new energy, new material, chemical pharmaceutical, nonferrous metal, precious metal... other products: PFA beaker, PFA reagent bottle, PFA drop bottle, PFA graduated cylinder, PFA scrubber bottle, PFA drop bottle, PFA microcolumn... FEP experimental utensils, PTFE experimental utensils, digestion apparatus, acid removal apparatus, acid purification system...
MAP7-20-E - Doser and Mixer for two-component epoxy resins Volumetric gear pumps oriented separately with inverters Electronic components pressure control for precise dosing and mixing of components (1:1 to 12:1) Electronically adjustable mixing ratio Manual dosing (through pedal or dedicated gun) or timed Tanks for resin and catalyst components in stainless steel (various options possible) Pneumatic pump for loading and recirculating the resin in order to keep the material mixed (Optional mechanical stirrer) Static dispensing head with separate and independent injectors, with anti-dripping system Standard connection, suitable for any type of disposable static mixer THE USE OF SOLVENTS IS NO LONGER NECESSARY Power Supply Voltage: 230 VAC 50/60 Hz Setup and Cleaning Time: 5 minutes LxWxH: 800x800x1500 mm Weight: 150 kg
Smoke Visibility Tester: Smoke Detection The test device is comprised of a plywood chamber with an inner side painted with heat-resistant paint and a hole in the ceiling that allows a light metre cell to be held while being tested. The chamber's bottom has a hole that lines up with the hole in the ceiling. The bottom hole has a clear glass bulb installed in it. A hole is present on the chamber's left side, and an exhaust fan has been mounted there. A hole on the right side allows air to circulate when smoke is being expelled into the chamber. A hinged door with a transparent glass pane is on the front of the chamber. The right-side and left-side holes of the chamber each have shutters. An electronics regulator installed in the instrument panel is used to control the LUX of the bulb. The black drape covered the front glass window and the hole in the ceiling. On the section stand, the chamber was mounted. The device comes with a LUX metre for measuring the LUX of the light. The device also comes with a stainless steel plate and an aluminium silicate plate. A stainless steel specimen frame with provisions to hold the specimen and slide the specimen frame is slanted at a 20�° angle to the vertical. On the chamber's bottom, a burner is fixed at a 45-degree angle. For the purpose of adjusting the gas supply, a flow metre, pressure gauge, and pressure regulator are installed on the section frame. For long-lasting corrosion resistance, all the pieces have been coated or polished. No gas will be included with the instrument from our end.
ASTM D2863 Oxygen Index Oxygen Index: Measuring the Minimum Oxygen Concentration to Support Candle-Like Combustion of PlasticsThe purpose of ASTM D2863 is to establish the lowest oxygen concentration in an oxygen/nitrogen combination necessary to sustain a flame burn on a plastic specimen. Real end use circumstances are not correlated. The test sample is placed vertically in a glass chimney, and a flow of oxygen and nitrogen is created there by starting at the bottom of the chimney. The test sample's top edge is lighted, and when the oxygen concentration in the flow falls, the flame eventually goes out. Specimen dimensions: Depending on the kind of material being tested, there are six requirements for the test specimen.
Our company is a professional manufacturer of laboratory products, engaged in the production, development, and sales of high-tech trace analytical laboratory containers, to fill the gap We have been in this line for about 30 years and we have our own design department and production line. We can ensure your quality and production line. OEM is warmly welcomed. We mainly produce laboratory products based on PFA materials, such as Beakers/reagent bottles/mixing bars/forceps/funnels/volume flasks/crucibles/mixing bars/water tanks/reaction bottles/washing bottles/measuring bottles, etc. Our products are sold all over the world (such as CUG, IGCAS, SGS, etc. ) And the quality of our products can be compared with foreign brands. They are well received by the experimenter in semiconductor, electronics, pharmaceutical, and other industries, and are widely used in the chemical industry. We continue to improve the quality of products and adhere to the customer, service, technology as the core. Along the way has been recognized by many customers, sincerely thank you for your support and help, but also look forward to working with you to reach a long-term cooperative relationship. In the future, we will continue to serve our customers and provide better-quality products.
SPD-V010 Handheld Roll Gap Checker Overview The handheld roll gap checker is specially used to measure the length between spherical surface, arc surface and plane (or spherical surface). It is specially suitable for the opening adjustment of the roll gap of the metallurgical continuous casters in various specifications, because the roll gap checker has the advantages of high resolution, accurate measurement, stable data and easy to use. Because the opening accuracy of the roll gap checker will directly affect the quality of the casting block, this roll gap checker is an indispensable testing equipment in the continuous casting equipment, which can fully meet the needs of on-site installation testing and use process verification. When the hand-held roll gap meter smoothly passes through the gap between the guide rolls of the continuous casting machine, the upper measuring contact of the hand-held roll gap checker contacts the inner arc roll and the lower measuring contact touches the outer arc roll. The handheld roll gap checker is used in perpendicular to the roll diameter direction, during the pushing process, when the hand-held roll gap meter is in the tangent plane of the upper and lower rolls, the measured value is the smallest at this time, and this value is the roll gap measurement value. The design of the hand-held roll gap gauge ensures that the upper and lower contacts of the roll gap checker can smoothly pass the measured roll along a straight line during measurement. During the measurement process, the roll gap measuring instrument automatically compares the measured values, and displays the minimum measured value on the instrument display interface, which is the current measured roll gap value. The technical parameters 1. Measuring range of instrument type handheld roll gap checker: 180mm - 400mm (the range can be customized) 2. Measuring range of digital hand-held roll gap checker: 120mm - 400mm (the range can be customized) 3. Measuring range of hand-held thin slab roll checker : 60mm - 150mm (the range can be customized) 4. Measurement accuracy: 0.01mm 5. Working temperature: 25 85 6. Battery capacity: 5000mAh 7. Charger specification: 12V
Nitrile gloves, ultra low temperature freezers 86 degrees, laboratory equipment and consumables..
Intra Ocular Lenses, Slit Lamps, Surgical Instruments.
Total station, video scope, flaw detector, xrf/libs analyzer, thermal imager, ndt equipment, 3d scanning, surveying equipment, laboratory equipment and other tester/analyzer.Export
Consumables like microscope supplies, surgical instruments.
Consumables like microscope supplies, surgical instruments.