The ZRS-3H Glow-wire Test Apparatus is according to IEC60695-2-1, IEC60695-2-10, IEC60695-2-11, IEC60695-2-12, IEC60695-2-13 (GB/T5169.10, GBT5169.11, GBT5169.12, GB/T5169.13) < Basic testing methods of Glow wire, basic testing methods of Glow wire device>, UL 746A, IEC829, DIN695 and VDE0471.
What is glow wire test?
The Glow wire tester ZRS-3H/ZRS-3HS is suitable for resistance to abnormal heat and fire test on lighting lamps, electronic products and household appliances. It uses high-temperature coating spraying on steel structure and imported instrument display, with easy operation and stable performance. The glow wire testing equipment is applicable to flame resistance test of all levels of QC departments and corresponding enterprises.
Specifications:
Heating temperature: adjustable continuously within the range of 25~1100C, the accuracy of temperature is 1C, the resolution of temperature is ±3C
Glow-wire time: 0.1-999.9s±0.1s(time range is adjustable)
Ignition time: 0.1-999.9s, auto record, manual pause
Flame-out time: 0.1-999.9s (auto record and manual pause)
Glow wire pressure on test specimen: 1±0.2N. Limiting pressure depth is 7mm
Glow wire: 4 nickel (80) and chromium (20) Made in specific dimensions.
Thermocouple: �?0.5 armored nickel & chromium/nickel-chromium wire, K Type.
Automatic departure: While reaching specified glowing time, test specimen will depart from glow wire automatically.
To save the delivery cost for the oversea market, LISUN designed a compact version glow-wire tester weighing less than 50kg. (Customer need to prepare additional ventilation system for ZRS-3HS)
Pipettes are indispensable tools in laboratories, research facilities, and medical settings, used to accurately measure and transfer liquids. To ensure consistent and reliable results, it's crucial to properly maintain and care for your pipettes. In this article, we'll provide essential tips for pipette maintenance to help prolong their lifespan and maintain accuracy.
1. Regular Cleaning
Clean your pipettes regularly to prevent cross-contamination between samples. Use a mild detergent and distilled water to clean the external surfaces. For the internal components, use a lint-free cloth dampened with isopropanol or ethanol to wipe down the pipette shaft and piston. Make sure to follow the manufacturer's guidelines for cleaning to avoid damaging delicate components.
2. Calibrations and Verification
Schedule regular calibrations and verifications of your pipettes to ensure accurate measurements. Calibration checks should be performed by trained professionals using calibrated equipment. Verification using gravimetric or photometric methods can help confirm the accuracy of your pipettes when dispensing specific volumes.
3. Proper Handling
Handle pipettes with care to avoid mechanical damage. Always use the appropriate force when operating the plunger to prevent excessive wear on internal components. Avoid dropping pipettes or subjecting them to impact, as this can lead to misalignment and inaccurate measurements.
4. Tip Selection and Replacement
Choose pipette tips that are compatible with your specific pipette model. Use high-quality, certified tips to ensure accurate and consistent results. Replace tips between each sample to prevent cross-contamination. Make sure the tips are securely attached to the pipette to prevent leakage or imprecise measurements.
5. Storage and Handling
Store your pipettes in a clean and dry environment to prevent dust and contaminants from affecting their performance. Use pipette stands to keep them upright and avoid contact with surfaces. If your pipettes are not in use for an extended period, store them with the plunger released to relieve stress on internal components.
Conclusion
Proper maintenance of pipettes is essential for obtaining accurate and consistent results in laboratory and medical settings. By following these tips and adhering to manufacturer guidelines, you can ensure that your pipettes remain in optimal condition, extend their lifespan, and contribute to the reliability of your research and analyses.
Cylinder : flexible, clear and calibrated measured volume chamber in size 110/150ml. Chamber has an in built Injection port and air inlet with bacteria filter. Automatic shut off floating valve provided in chamber to prevent air trapping and to indicate volume of fluid in the chamber. 15 micron fluid filter in the drip chamber. 15 micron fluid filter in the drip chamber. Delivers approximately 60 drops/ml. Soft and kink resistant PVC tube, 150 cm long, 22G Silconized Needle� � with double colour printed in HM bags and packed with 10 pcs in a outer bag and filled� � with 200 pcs per Shipper
A demineralizer is used to purify water and make it better for drinking. It can be used for any type of water that needs to be purified or aerated, whether itâ??s contaminated with chemicals or gasses, has a smell or a cloudiness, or simply doesnâ??t taste good. The demineralizer reaches its maximum efficiency when most of the impurities are removed from the water but the water is still clear, odorless and tasteless.
Laboratory Demineralizer With the support of diligent team of professionals, R S Enterprises is known as a leading manufacturer, supplier, exporter and trader of Water Purifier Plant, Water Softener, RO System Spare Part, Solar Lamp, Water Demineralizer, Solar Panel and many more. We also render highly reliable and effective RO System Installation Service to the customers. We have started our business in the year 2010 as a partnership based company at Chennai in Tamil Nadu, India. Our products are highly appreciated among the customers for their high reliability, advance technology, hassle free performance, excellent finishing, less maintenance requirement, long service life and various other features. Moreover, we use high grade inputs, advance technology and innovative ideas of our skilled technician in the manufacturing of these products. Our dedicated team of skilled professionals enables us to deliver the bulk consignments of customers on time with maintaining world class standards in our products. Our exporting countries are East Asia, North Asia, South Asia, Germany and Indian Subcontinent.
4348 Laboratory Equipments Instruments Suppliers
Short on time? Let Laboratory Equipments Instruments sellers contact you.
Heavy weight double-sided reflectors are incredibly versatile and can be used in a wide variety of underground applications
Constructed from microprism retroreflective vinyl with brass grommets, these reflectors are extremely bright and offer true color reflection.
With 11 different color options available, they can be used to create a complete mine color code identification system. Both sides of the reflector can be the same color or different colors, and one side may also be non-reflective.
The reflectors are flexible and impact resistant and have a smooth surface that can be easily wiped clean.
They can be installed quickly using an S-hook or special roof plate clip.
4. Performance specifications
1. Temperature range: RT+40 -70
2. Humidity range: 90% RH
3. Temperature control accuracy: ± 3
*Note: The performance guarantee of item # 5 above requires testing at a distance of 1/6 of each wall surface in the testing area, and must be measured after stabilizing with temperature and humidity for 30 minutes
4. Equipment placement space: at least 207 two hundred and seven 201cm (W H D)
5. Power supply: AC220V 50HZ
5 System structure
1. Heating system: Scaled stainless steel electric heating tube
2. Humidification system: glass nozzle
3. Temperature sensing system: Made of stainless steel SUR304Pt100
4. Control system: The control system adopts a P.I.D controller, which controls temperature and humidity simultaneously
a. Controller specification: Accuracy: Temperature ± 2.0 +1 digit, with upper and lower limit standby and alarm functions
5. Box material
Inner box material: SUS # 304 mirror stainless steel plate
Outer box material: SUS # 304 stainless steel plate
2.Technical parameters:
1. Box size in the laboratory:
DL-120LA W1200 * D1000 * H500 (mm),
Approximate dimensions: 2300 * 1300 * 1400mm,
2 standard temperatures,
Laboratory temperature: nss acss 35 ± 1 /pass 50 ± 1
Pressure bucket humidity: nss acss 47 ± 1 /pass 63 ± 1 ,
Salt water temperature: 35 ± 1
It can be heated without water,
3 volumes,
Laboratory capacity: 800L Salt water tank capacity: 40L,
4 compressed air,
Compressed air pressure: 1.00 ± 0.01kgf/c
5 spray volume: 1.0-2.0ml/80c /h,
6 spray mode: continuous spray, timed spray, programmable spray, intermittent spray, demisting in the box,
7. Power supply: AC220V 50Hz/20A,
8. Material: The entire PVC board is made, and the salt spray testing machine adopts advanced three-dimensional reinforcement technology internally, with a strong and solid structure that never deforms.
9. Water adding method: An automatic water adding system is adopted, which has the function of automatically replenishing the water level when the water level is insufficient, and the test is not interrupted.
10. Nozzle: Precision glass nozzle, salt spray testing machine used for 4000 hours to ensure no crystal blockage.
11. Protection system: Equipped with dual over temperature protection and insufficient water level warning to ensure safe use.
12. Temperature controller: digital display, PID control, high stability platinum temperature probe, error 0.3
13. Heating method: The laboratory adopts direct steam heating method, which increases the temperature quickly and shortens the standby time of the salt spray testing machine.
14. The spray tower is equipped with two conical dispersers, which have the functions of guiding fog, adjusting fog volume, and even fog falling.
15. The pressure bucket adopts Henry's law to heat and humidify, and provide the humidity required by the salt spray testing machine laboratory.
16. Opening method: Pneumatic automatic opening is adopted,
The salt spray testing machine is one of the "three prevention" (humid heat, salt spray, mold) testing equipment for artificial climate environments. It is an important salt spray testing equipment for studying the adaptability and reliability of various environments in industries such as machinery, national defense, light industry, electronics, light industry electronics, and instruments. This salt spray testing machine can perform neutral salt spray tests in accordance with GB/T2423.17 "Basic Environmental Testing Regulations for Electronic and Electrical Products - Test Ka: Salt Spray Test Method", and can also perform acetate spray tests. This salt spray tester complies with CNS, ASTM, JIS and ISO standards. The salt spray test is to test the corrosion resistance of the products after coating, electroplating, Anodizing, anti-rust oil and other anti-corrosion treatments on the surfaces of various materials.
1.)Performance specifications:
1. Machine model: DL-4100,
2. Capacity: 100L,
3. Temperature range: -40 -150 ,
4. Humidity range: 20% -98% RH,
5. Temperature and humidity control accuracy: ± 0.5 ± 2% RH,
*Attention: The performance guarantee of items # 2-4 above should be measured after 30 minutes of stable temperature sensing
6. The temperature and humidity are evenly distributed: ± 2.0 ± 5.0% RH,
*Note: The performance guarantee of item # 5 above requires testing at a distance of 1/6 of each wall surface in the testing area, and must be measured after stabilizing with temperature and humidity for 30 minutes
7. Inner box size: 500 high Width 400 500mm deep,
8. Outer box size: 1700 high Width 1000 1500 mm deep,
9. Equipment placement space: at least 2000 2000 2000mm (W H D) ,
10. Power supply: AC220V 4.5KW, 50HZ
Product introduction:
HAST (Highly Accelerated Stress Test) is a type of test that is used to evaluate the reliability of electronic components and other materials under high temperatures and humidity. A HAST test chamber is a device that provides controlled conditions of high temperature and humidity to simulate the effects of aging and degradation on materials over a shorter period of time than would occur in normal use.
During testing, the sample to be evaluated is placed in the HAST chamber, which is then heated to a high temperature and subjected to a high-pressure steam environment. The temperature and humidity levels are carefully controlled to ensure that the sample is subjected to the appropriate conditions.
The purpose of the HAST test is to identify any weaknesses or defects in the material that may cause it to fail prematurely in real-world use. By exposing the sample to accelerated aging conditions, engineers can evaluate the long-term reliability of the material and make any necessary improvements to its design.
HAST test chambers are commonly used in the development and testing of electronic components, such as integrated circuits, printed circuit boards, and semiconductor devices. They are also used in other industries where materials must be able to withstand harsh environmental conditions, such as the aerospace, automotive, and medical device industries.
Bench-top Type Temperature(&Humidity) Test chamber:
The Bench-Top Type Temperature Humidity Chamber most ideal designed for temperature and humidity testing of small samples and specimens used for research, development and quality control. Daily necessities, cosmetics, electronic components, and medical products must meet certain quality standards and testing specifications. That size that can fit on a personal desk is the most consideration.
Features:
7inch big PLC touch screen color display for easy operation
Temperature Humidity control and display unit
Safety protection system
Desk top, Table top, Bench Top Fit
UV accelerated aging test chamber can simulate environmental conditions such as self-climate ultraviolet rays, rain, high temperature, high humidity, dew condensation, darkness, etc. By reproducing these conditions, it is merged into a cycle, and it automatically executes the number of cycles completed. In this process, the equipment can be used for automatic monitoring of blackboard temperature and water tank temperature; by configuring irradiance measurement and control device (optional), the irradiance can be measured and controlled, and the irradiance is stable at 0.76W/m2/340nm or specified setting. Fixed value, greatly extending the service life of lamps.
Climatic Temperature Humidity Test Chamber provide constant humidity and heat, complex high and low temperature alternating and other test environment and test conditions for electronic components, industrial materials and finished products in development, production and testing processes, applicable for electronic appliances, telecommunications, chemicals, hardware, rubber, furniture, toys scientific research etc.
Applicable industries:
Isotope industry, heavy metal industry, semiconductor, new energy, new material, chemical pharmaceutical, nonferrous metal, precious metal...
Product Features:
1. Material: PFA (fusible polytetrafluoroethylene, Teflon)
2. Transparency: translucent
3. High and low temperature resistance: -200C to 260C
4. Corrosion resistance: resistant to strong acid and alkali, aqua regia, HF, and various organic solvents
5. No leaching out, no sticking samples, it is an excellent container for storing standard substances
6. The blank value of metal elements is low, and the content of lead and uranium is lower than 0.01ppb
Product Usage:
Processing samples
Compatible with pipette, condenser, separatory funnel
It can be used in condensation reflux device and hydrogen fluoride distillation experiment
Applicable industries:
Isotope industry, heavy metal industry, semiconductor, new energy, new material, chemical pharmaceutical, geochemistry, geology and mineral...
Product Features:
1. PFA material (translucent)
2. High and low temperature resistance: -200C to 260C
3. Strong acid and alkali resistance, high temperature resistance
4. No dissolution and precipitation, no contamination of samples
5. The principle of sub-boiling distillation and heat radiation.
6. Innovative advantages: Timed and segmented temperature control, annular heating jacket, liquid level gauge, pagoda-shaped condensation chamber
Laboratory planning and design is a critical process in the creation of a functional and efficient laboratory environment. The process involves careful consideration of the laboratory's purpose, the types of experiments and research to be conducted, and the equipment and personnel needed to achieve these goals. Effective laboratory planning and design can increase productivity, enhance safety, and improve overall laboratory performance.
The first step in laboratory planning and design is to define the laboratory's purpose and scope. This includes identifying the types of experiments and research to be conducted, as well as the equipment and personnel needed to achieve these goals. A thorough understanding of the laboratory's purpose and scope is essential for developing an effective laboratory layout and design.
The next step is to develop a laboratory layout that maximizes space utilization and minimizes the potential for hazards. The layout should consider the flow of people and materials, the location of equipment, and the positioning of workstations. Careful consideration should also be given to safety and ergonomic factors, such as minimizing the risk of accidents, reducing strain on personnel, and ensuring easy access to equipment.
In conclusion, laboratory planning and design is a critical process for creating a safe, functional, and efficient laboratory environment. It involves careful consideration of the laboratory's purpose and scope, the layout and design of the laboratory space, and the selection and installation of appropriate equipment. By following these guidelines, laboratories can optimize their performance and achieve their research goals.
4348 Laboratory Equipments Instruments Suppliers