Medical lab instruments.
Scientific equipment like hydrometers, scientific apparatus and equipment.
State of the Art Micro controMulti hook calibration. Selective duty code. Warns the operator of any type of over limits such as hook over hoist, Over Load etc. Hydraulic cut off (optional) System is user friendly and simple Tension Meter : High Quality, Reliable & durable:- eliminates 3 pulley system of dynamometer and gives you wear & tear free mechanism. No risk of Rope damage. High accuracy. Switch : Unique, high Quality ergonomic design, Water Proof, Non corrosive Ball joint technology. Dual contact and dual switch. Length and Angle Detection: It is pre-calibrated and measures Length and Angle ( MEMS Chip Technologies ) It is a Combination of two Transducers in a Single unit. State of the Art Micro controller designDisplay System :Two Line Alpha Numeric, display Shows Rated Load, HookLoad, Length, Radius and Angle.
Respirable Dust Sampler The practise of assessing contaminants in the amount of air that can be inhaled by employees at a certain location is known as espirable dust sampling. To ensure that workers' health is not in danger, a variety of dust sampling techniques are employed to measure the amount of dust particles and chemical vapours. With industrial employees who are frequently exposed to vapours, gases, and particles, respirable air sampling is fairly common. By monitoring the air, hazardous substances that are still present in the atmosphere can be found and effectively controlled. Product Description FDS (2.5 / 10) made by KDM PM TRAVELING FINE DUST SAMPLER (Can Monitor Either PM 2.5 OR PM 10 at a time) Model-based on a microprocessor (DATA LOGGER FOR ALL 5 PARAMETERS) Developed in accordance with international standards, USEPA regulations, and Indian CPCB guidelines PM EPA 2.5 Size Separator PM 2.5 SUCCESS EPA Impactor PM 10 Size Separator Using a 10 separation assembly and a sample transfer tube, the omnidirectional ambient particle inlet. Filter Cassette with a 47 mm Filter Media is placed in a Filter Holder assembly. Volume Totalizer & Flow Rate Meter (USEPA Procedure Followed) Actual operating conditions are shown as Flow in LPM on a Digital Display with a Resolution of 0.01 LPM. Throughout the sampling period, the flow rate was kept constant at 16.67 LPM with a 2% accuracy thanks to a microprocessor-based digital flow controller. Timer/Clock System Programmable Real-time control system with automatic start and stop, digital time and date display, and sampling time display. Precision 2 min/month. Temperature Sensors For Filter Temperature Range & Ambient Temperature Range: 5 to 50 C with a 0.10 C resolution. Range of the bar press sensor is 600 to 800 mm Hg. 1 mm Hg as the resolution Display 20x4 LCD display calibrated by FCRI PALLAKKED presenting parameters in real time, i.e. Flow Rate (16.67 LPM). Volumetric flow, barometric pressure, ambient temperature, and filter temperature output are all included. USB Flash Drive with RS-232C terminal for connecting to a computer (Optional) Dimensions and Weight of Calibration Factory Calibration Certificate: (17x13x19)/Approx. 25 Kg
High Volume Air Sampler for PM2.5 Global's line of extremely reliable and durable samplers created for capturing particulate matter and gaseous contaminants in ambient air are known as High Volume Air Samplers (HVAS). The High Volume Air Sampler (HVAS) is a piece of equipment used to sample huge amounts of ambient air in order to filter out the particulate matter it contains. Finely divided solids or liquids that are spread in the air from natural sources, industrial operations, or both are referred to as particulate matter. To stop collecting of particles larger than a certain size, a Size Selective Inlet (SSI) is used as a pre-filter. Size Selective Inlet (SSI) PM 2.5 only allows particles with an AED 2.5 micron diameter to enter the collection medium; particles larger than 2.5 microns are not allowed. Features of the physical design: High Volume Air Samplers, such as the PEV-HVS and PEM- RDS series, PM2.5HVS, are made up of a large blower, a filter to catch suspended particles, and a way to gauge the flow rate. Through the side apertures of the SSI, suspended airborne particles are sampled at sampling rates ranging from 1.1 to 1.6 m3/min and collected on a 203 x 254 mm filter paper. Important Features: Electronic Control Module with a Microprocessor; 32-character LCD Module with alphanumeric characters; Electronic Timer Cumulative Totalizer. Continuous Duty Blowers; Settable Delay & Sampling Time The exhaust orifice plate meets with USEPA standards. An optional gaseous sampling attachment for all models. By replacing the gable roof with SSI, it can be transformed into a PM10 sampler. Unique Characteristics: Free flow without resistance at 1.1 to 1.7 Cu m/min flow rate. Particle Size: Depending on the filter being used, down to 0.3 micron. Filter holder made to fit any standard 8 X 10 (20.3 X 25.4 cm) size filter sheet. The GF/A filter is advised for general use, and EPM 2000 for specialised research. Time Totalizer: Record the running time in hours from 0 to 99999.99 hours for sampling time: Automatic Sampling: A 24 hour programmable timer that automatically turns the device on or off after the preset intervals can be easily set. 220 volts, 5 amps, single phase AC power requirements. Rotameter flow rate is measured with a plastic body flow metre with a 2% FSD accuracy between 0 and 3 lpm.
Product Description: Single-flame source test, commonly known as the ignitability test.Test equipment complies with standard EN ISO 11925-2. Building structure test findings can be categorised using standard 13501-1. The test specimens' measurements must be (250) mm length by (90) mm broad.The burner is moved horizontally at a 45 angle until the flame, which has a 20 mm length, touches the test specimen at the predetermined position. Testing may be required for edge exposure, surface exposure, or both. As determined by the sponsor, the flame application time is either 15 or 30 seconds. The following information is noted during the test: whether ignition happens; whether or not, and when, the flame tip rises 150 mm above the flame application point; whether the filter ignites Standards: EN ISO 11925-2, DIN 4102 Technical parameters: This apparatus made up of two parts burning chamber and control device Power supply AC220V 10%,50Hz Burner diameter 0.17mm burner with regulator; four  4mm air suction inlet Gas source 95% propane gas;(user should provide for themselves) Gas pressure 10kpa 50kpa Flue air velocity 0.7m/s only on condition of burner burning and draught hood open Time adjustment of continuous flame 0 99minutes99seconds Time adjustment of afterflame 0 ~ 99minutes99seconds Timer accuracy 1s/h
Pneumatic trainer kit and hydraulic trainer kit, ITI labs setup, ITI material.trade
Laboratory instruments, apparatus like tablet disintegration test apparatus, friability test apparatuses, shakar like sieve shaker, rotary shaker, water bath shaker, digital griffin flask shaker, orbital shaker incubator, jar testing apparatus, flocculator, antibiotic zone reader (manual), bulk density test machine (analog/digital), vortex mixer, and colony counter..Manufacturer & exporter
Autoclave, sterilizer, bath and circulator, freeze dryers, laboratory shaker, chamber, biological safety cabinet, centrifuge, co2 incubator, ultra low temperature freezer, fume hood, furnaces, ice maker, laminar air flow hood, oven, incubator, spectrophotometer.
Scientific, pharmaceutical, medical instruments.
Scientific laboratory & medical equipments.
Lab instrument and medical equipment - pathological microscope, stereoscopic microscope, stereo, zoom , slit lamp , lens meter , E.N.T., microscope , over head projector , tissue culture microscope.
Spectrometers, traveling/vernier microscopes, newton’s ring microscopes, six position microscope, coordinate measuring microscope, tool makers microscopes, ticker tape timer, force table wheat stone bridges, kelvin bridges, dissecting set, polarimeters, ovens, incubators, muffle furnace, autoclaves, vacuum pumps, rheostats, meters, plug keys, vernier callipers, screw gauges, slotted weights, first aid kits, milliken’s oil drop app, motor models, tangent galvanometer, dynamo AC DC models, newton’s color discs, freeze dryers, humidifiers, homogenisers, laminar air flow, fume hoods, ice makers, plant growth chamber, seed germinators, incubator shakers, orbital shakers, PCR machines, petrol and diesel engines models, power supplies, induction coils, whimshurt machines.
Dairy equipments for milk fat analysis, S.S. milk collection accessories, scientific instruments for educational institutes, laboratory equipments & glasswares.
Surgical and scientific instruments, hospital furniture and equipments.
Scientific, laboratory, medical products.We provide consultancy in all types of computer softwares
Scientific, educational teaching aids, laboratory glassware & physics instruments.Establish business cooperation with the company interested in our manufacturing range
Pressure gauge, temperature gauge, testing equipment & related accessories.
All kinds of scientific & surgical goods.
Medical & laboratory instruments.