CAT No : RK025-40. One step, rapid immunothematographic test for the differential detection between Plasmodium falciparum Histidine- Rich Protein II (HRP II) and Plasmodium species (P. falciparum , P vivax P. ovale, P. malariae) lactate dehydrogenase (pLDH) in human whole blood Kit Contents: Standard Q Malaria Pf/PV Ag cassette x 40 Specimen transfer device 3 microlitre x 40 Butter bottle 3m1 x 02 Instructions for use x 01 STANDARD Q Malaria P.f Ag qualitatively analyzes Plasmodium falciparum and CAT Cat.No : RK025-40. Plasmodium vivax antigens in whole blood using immunochromatography. The target antigen is Histidine-Rich Protein II (HRP-II) of Plasmodium faciparum and plasmodium lactate dehydrogenase (pLDH) of Plasmadium vivax, and the screening test result can be obtained within 15 minutes with its high sensitivity and specificity Advantage: Distinguish the infection between P.falciparum and P.vivax Optimized on-site diagnosis with the small diagnostic kit Able to read positive/negative infections fast and accurately with a little blood (5�µl) Room temperature storage.
Cat No : PI19FRC25. First Response Syphilis Anti-TP Card Test is intended for use by healthcare professionals and qualified laboratory personnel. It is a rapid, qualitative, screening, in vitro diagnostic test for the detection of antibodies of all classes specific to Treponema pallidum in human serum, plasma or Venous or capillary whole blood. Product specifications : 100% - Specificity 100% - Sensitivity Detects antibodies specific to Treponema pallidum Rapid Result time within 20-25 Minutes Storage at 4-30C Specimen Type Whole blood, serum, plasma Shelf Life: 24 Months
CAT No : PI19FRC25. First Response Malaria Ag. P.f. / P.v. Card Tests intended to be performed by trained users (In either laboratory or point of care settings) as qualitative screening in vitro diagnostic test for detection of P. falciparum and P. vivax. Product specifications : Sensitivity - 100% Specificity -100% Rapid Result time within 20 - 30 Minutes. Detects P. falciparum and P. vivax. Storage at 1 40C. Specimen Type- Whole Blood.
Cat No : 11FK50. Bioline DENGUE NS1 Ag TEST FOR EARLY CLINICAL PHASE OF DENGUE INFECTION Bioline Dengue NS1 Ag rapid test is an in vitro immunochromatographic assay designed to detect Dengue virus NS1 antigen in human serum, plasma or whole blood. Product not available in all countries. Please check with your local sales representative regarding availability in your area. Benefits: Diagnosis of early acute dengue infection by detecting dengue NS1 antigen Dengue NS1 antigen can be detected from 1 day after onset of fever Specimen : Serum, plasma or whole blood (100�¼l) Test result : 15~20 minutes Specification: Sensitivity 92.4%, Specificity 98.4%
Cat No :14FK10 Bioline* Rotavirus test is an immunochromatographic assay for the detection of Group A rotavirus in human fecal specimens. The test utilizes two kinds of antibody in a solid phase sandwitch immunochromatography to detect group specific proteins, including the major inner capsid protein, present in Group A rotaviruses. â?¢ Early detection of rotavirus antigen group A all serotype Shelf life and storage temperature: 18 months from the date of manufacturing at1-30 C Performance: Sensitivity: 94 %, Specificity 98.3 % (vs. RT-PCR)
Cat No : ACKCRDPC3. Product Description : Acon Pregnancy Test Strip (HCG) is a one step pregnancy test kit containing test strip. The urine sample is to be collected in a clean, dry container and almost half test strip should be dropped inside the container. The first urine sample of the day is preferred. The pack insert should be thoroughly read before use. To know how to use and read test results. Acon pregnancy test strip detects pregnancy in just 5 minutes. Features & Specifications : One Step Pregnancy Test Strip, Easy to Use, Quick Result in just 5 minutes, Pack of 3 Test Strips, For more info, please refer the product pack for usage instructions.
Product Details: Number of Reactions(Preps)/Kit : 10T Brand : SD Biosensor ICMR Approved : Yes Result Time (Rapid Kits) : 15 min CAT No : RK013-10 One step, rapid, immunochromatographic test for the detection of IgM/IgG antibodies to four serotypes of dengue virus (DEN-1, DEN-2, DEN-3 and DEN-4) & Dengue virus NS1 antigen in human serum, plasma or whole blood. Kit Contents: Standard Q Dengue Ag Ab Duo cassette x 10 Specimen transfer device 10ml x 10 Butter bottle 4ml x 01 Instructions for use x 1 STANDARD Q Dengue Duo test is an immunochromatographic assay for the detection of NS1 antigen and Dengue virus-specific IgM and IgG antibodies in human serum, plasma and whole blood. By detecting the NS1 antigen, not only the initial infection can be detected, but also Dengue virus-specific IgM and IgG can be detected at the same time. Screening test results can be obtained within 15 minutes with high sensitivity and specificity.
Product Details: Number of Reactions(Preps)/Kit :20T Brand : SD Biosensor ICMR Approved : Yes Result Time (Rapid Kits) : 15min CAT No : RK012-20 One step, rapid, immunochromatographic test for the detection of Dengue IgMlIgG antibodies to four senatypes of dengue virus (DEN-I, DEN-2. DEN-3 and DEN-4) in human serum, plasma or whole blood. Kit Contents: Standard Q Dengue IgM IgG cassette x 20 Specimen transfer device 10ml x 20 Butter bottle 4ml x 01 Instructions for use x 1 STANDARD Q Dengue IgM/IgG qualitatively analyzes IgM and IgG antibodies specific to Dengue virus in serum, plasma and whole blood using immunochromatography. By detecting IgM and IgG specific to Dengue virus, the primary and secondary Dengue virus infections can be discriminated, and the screening test result can be obtained within 15 minutes with its high sensitivity and specificity. Advantage: Differential detection of IgG and IgM antibodies Easy to use, Easy to read and interpret Room temperature storage Able to read positive/negative infections fast and accurately with a little amount of sample (10 �µl)
Product Details: Number of Reactions(Preps)/Kit 40T Brand ; SD Biosensor ICMR Approved : Yes Result Time (Rapid Kits) : 15min CAT No : RK025-40 One step, rapid immunothematographic test for the differential detection between Plasmodium falciparum Histidine- Rich Protein II (HRP II) and Plasmodium species (P. falciparum , P vivax P. ovale, P. malariae) lactate dehydrogenase (pLDH) in human whole blood Kit Contents: Standard Q Malaria Pf/PV Ag cassette x 40 Specimen transfer device 3 microlitre x 40 Butter bottle 3m1 x 02 Instructions for use x 01 STANDARD Q Malaria P.f Ag qualitatively analyzes Plasmodium falciparum and Plasmodium vivax antigens in whole blood using immunochromatography. The target antigen is Histidine-Rich Protein II (HRP-II) of Plasmodium faciparum and plasmodium lactate dehydrogenase (pLDH) of Plasmadium vivax, and the screening test result can be obtained within 15 minutes with its high sensitivity and specificity Advantage: Distinguish the infection between P.falciparum and P.vivax Optimized on-site diagnosis with the small diagnostic kit Able to read positive/negative infections fast and accurately with a little blood (5aul) Room temperature storage.
Product Details: Number of Reactions(Preps)/Kit : 40T Brand : SD Biosensor ICMR Approved : Yes Result Time (Rapid Kits) : 15 min CAT No : RK027-40 STANDARD Q Malaria P.f Ag qualitatively analyzes Plasmodium falciparum and Plasmodium species antigens in whole blood using immunochromatography. The target antigen is Histidine-Rich Protein II (HRP-II) of Plasmodium faciparum and plasmodium lactate dehydrogenase (pLDH) of Plasmadium species, and the screening test result can be obtained within 15 minutes with its high sensitivity and specificity. Distinguish the infection between P.falciparum and others Optimized on-site diagnosis with the small diagnostic kit Able to read positive/negative infections fast and accurately with a little blood (5aul) Room temperature storage
Product Details: Number of Reactions(Preps)/Kit: 30T Brand : SD Biosensor ICMR Approved : Yes Result Time (Rapid Kits): 10 min Country of Origin : Made in India CAT No : RK026-30 STANDARD Q HBsAg performs qualitative analysis by specifically detecting the surface protein antigens of hepatitis B virus in serum, plasma and whole blood using immunochromatography. With a simple test method, hepatitis B infection can be discriminated early, and with its high sensitivity and specificity, the screening test result can be obtained within 20 minutes. Easy to use, Easy to read and interpret Room temperature storage Performance Sensitivity : 100% (43/43) / Specificity : 100% (162/162)
Product Details: Number of Reactions(Preps)/Kit : 20T Brand ; SD Biosensor ICMR Approved ; Yes Result Time (Rapid Kits) : 15 min CAT No : RK029-20 STANDARD Q TSUTSUGAMUSHI IgM/IgG is a rapid,sensitive,qualitative Immunochromatographic assay for the detection of IgM/IgG antibodies against Orientia Tsutsugamushi in human serum,Plasma or whole blood specimen.it is an initial screening test and this test kit is for in vitro use only by professionals. Differential detection of IgM & IgG Antibodies Easy to use,Easy to interpret Long term storage Faster results with lesser specimen volume (10aul)
Product Details: Number of Reactions(Preps)/Kit : 20T Brand : SD Biosensor ICMR Approved : Yes Result Time (Rapid Kits) : 15 min CAT No : RK024-20 STANDARD Q Chikungunya IgM/IgG qualitatively analyzes IgM and IgG antibodies specific to Chikungunya virus in serum, plasma and whole blood using immunochromatography. Screening test results can be obtained within 15 minutes with high sensitivity and specificity. Differential detection of IgG and IgM antibodies Easy to use, Easy to read and interpret Room temperature storage Able to read positive/negative infections fast and accurately with a little amount of sample (10 aul)
Product Details: Number of Reactions(Preps)/Kit : 25T Brand : SD Biosensor ICMR Approved : Yes Result Time (Rapid Kits) : 15 min CAT No : 09FIL10D Filariasis Ag Test Kit Contents: Test Device in a foil pouch with desiccant Disposable dropper Instruction for use
Product Details: Number of Reactions(Preps)/Kit : 30T Brand : SD Biosensor ICMR Approved : Yes Result Time (Rapid Kits) : 15 min CAT No : RK018-30 STANDARD Q HCV Ab qualitatively analyzes antibodies specific to hepatitis C virus in serum, plasma and whole blood using immunochromatography. With a simple test method, hepatitis C infection can be discriminated early, and with its high sensitivity and specificity, the screening test result can be obtained within 5 minutes. Easy to use, Easy to read and interpret Room temperature storage Performance Sensitivity : 98.9% (92/93) / Specificity : 100% (168/168)
Product Details: Number of Reactions(Preps)/Kit : 50T Brand : SD Biosensor ICMR Approved : Yes Result Time (Rapid Kits) : 10 min CAT No : RK022-50 "STANDARD QA Ultra-DotA HIV Test is a rapid, sensitive andqualitative immunochromatographic assay to detect circulatingantibodies against HIV in human serum or plasma. The test is for invitro diagnostic use and is intended as an aid to early diagnosis ofHIV infection. This test is intended for professional use only as aninitial screening test."
Product Details: Number of Reactions(Preps)/Kit : 50 Brand : SD Biosensor ICMR Approved : Yes Result Time (Rapid Kits) : 10 min CAT No : RK023-50 STANDARD QA Ultra-DotA HCV Test is a rapid, sensitive andqualitative immunochromatographic assay to detect antibodiesagainst HCV in human serum or plasma. This test is for in vitrodiagnostic use and intended as an aid to early diagnosis of HCVinfection in patient with clinical symptoms with HCV infection.The test provides an initial screening result only. More specificalternative diagnosis methods should be performed in order toobtain the confirmation of HCV infection.
Product Details: Brand : Boditech Med Incorporated Size : 25 T Samples : Human serum/plasma/ control Specimen volume : 75 Microliter stored at ; 4 - 30 DegreeC Cat No ; CFPC-44 T3 Assessing to diagnosis & to monitor thyroid diseases(T3) This test assesses the level of T3 in the blood to diagnose thyroid dysfunction, help to receive appropriate treatment, and help to confirm the treatment effect through periodic measurement. INTENDED USE : ichroma T3 is a fluorescence Immunoassay (FIA) for the quantitative determination of triiodothyronine (total T3) in human serum/plasma. It is useful as an aid in management and monitoring of determination of thyroid disorders. For in vitro diagnostic use only. PRINCIPLE : The test uses a competitive immunodetection method. In this method, the analyte in the sample binds to the fluorescence labeled (FL) detection antibody in detection buffer, to form the complex as sample mixture. This complex is loaded to migrate onto the nitrocellulose matrix, where the covalent couple of T3 and bovine serum albumin (BSA) is immobilized and interferes with the binding of analyte and fluorescence labeled (FL) antibody. If more analytes exist in the sample, less detection antibodies are accumulated, resulting in less fluorescence signal. MATERIALS SUPPLIED : REF CFPC-44 Components of ichroma T3 Cartridge Box: - Cartridge 25 - Detector tube 25 - Detector diluent 2 - ID chip 1 - Instruction for Use 1
Product Details: Brand : Boditech Med Incorporated Size : 25 T Specimen : Human serum/plasma/ control Specimen volume : 75 microliter stored at 4 - 30 DegreeC. Cat No : CFPC-26 T4 Assessing to diagnosis & to monitor thyroid diseases(T4) Thyroxine (T4) is a type of thyroid hormone. An abnormal amount of T4 may indicate thyroid disease. The T4 test measures total T4, including T4 bonded to protein and free T4. A T4 test will help determine what type of problem is affecting the thyroid. INTENDED USE : ichroma T4 is a fluorescence Immunoassay (FIA) for the quantitative determination of thyroxine (T4) in human serum/plasma. It is useful as an aid in management and monitoring of thyroid disorder. For in vitro diagnostic use only. PRINCIPLE : The test uses a competitive immunodetection method. In this method, the target material in the sample binds to the fluorescence (FL)-labeled detection antibody in detector, to form the complex as sample mixture. This complex is loaded to migrate onto the nitrocellulose matrix, where the covalent couple of T4 and bovine serum albumin (BSA) is immobilized on a test strip, and interferes with the binding of target material and FL-labeled antibody. If the more target material exists in blood, the less detection antibody is accumulated, resulting in the less fluorescence signal. MATERIALS SUPPLIED : REF CFPC-26 Components of ichroma T4 Cartridge Box: - Cartridges 25 - ID Chip 1 - Insert 1 - Detector tube (Granule) 25 - Detector diluent (5.5 mL) 1
Product Details: Brand ; Boditech Med Incorporated Size : 25 T Samples: human whole blood/serum /plasma Specimen volume human whole blood/serum/ plasma stored at 4-30 C Cat. No. : CFPC-66 Human Chorionic Gonadotropin (�²-hCG) Distinguish pregnancy and abnormal pregnancy The IhCG test can be used to confirm pregnancy, the age of the fetus, abnormal pregnancy (ectopic pregnancy), potential miscarriage, and down syndrome. INTENDED USE : ichroma -HCG Plus is a fluorescence Immunoassay (FIA) for the quantitative determination of -HCG in human whole blood/serum /plasma. It is useful as an aid in management and monitoring of beta human chorionic gonadotropin (hCG) level in human For in vitro diagnostic use only. PRINCIPLE : The test uses a sandwich immunodetection method; Dried antibodies in the detector tube, once diluted with the diluent, bind with antigens in the sample to form antigen-antibody complexes. These complexes then migrate through the nitrocellulose matrix and are captured by another sets of immobilized antibodies on the test line. The more antigens in the sample, the more antigen-antibody complexes, which leads to a stronger fluorescence signal. This signal then is interpreted by the reader to display the �²-HCG concentration in the sample. STORAGE AND STABILITY : The cartridge is stable for 20 months (while sealed in the original aluminum foil pouch) if stored at 4-30 C. The detector, diluent and sample diluent are stable for 20 months if stored at 2-8 C. After the cartridge pouch is opened, the test should be performed immediately. MATERIALS SUPPLIED : REF CFPC-66 Components of ichroma-HCG Plus Cartridge Box: - Cartridges 25 - ID Chip 1 - Instruction For Use 1 Buffer Box For ichorma II - Detectors (Capped with plastic lid) 25 - Diluent 1 For AFIAS-50 - Detectors (Sealed with aluminum foil) 25 - Diluent 1 Sample Diluent Box: - Sample Diluent Tubes 25