Coaxial cables.
Conductor: Plain annealed Fire barrier: Mica Tape Insulation: XLPE Filler: Polypropylene yarn Binder Tape: Polypropylene Sheath : LSOH compound.
These cables are designed for transmission of anglog and digital signals, and the interconnection of electrical equipment and instruments, particular for the process control industry. Conductors: Annealed solid copper(Class 1), stranded(Class 2), or flexible(Class 5) to BS 6360. Insulation: PE/XLPE. Screen: (Overall Screen) (Indiviudual Screen + Overall Screen) (Overall Screen + Steel Wire Armour) (Individual Screen+ Overall Screen+Steel Wire Armour) Sheath Version: PVC/LSF/LSOH. Pair Ideatification: a) Collectively screened cables: Color coded in accordance with Color Code as per BS5308 standard. b) Individually screened pairs: One white core and one black core in each pair. Pairs identified by numbered screen isolation tape.
Handy Extension Wire for different kind of plugs. 2 meter wire. Size :39x45x49 Volume :0.09 Cubic Metres Weight :35. Quantity Per Carton :200.
Application These cables are designed for transmission of analog and digital signals, and the interconnection of electrical equipment and instruments, particular for the process control industry. Conductors: Annealed solid copper(Class 1), stranded(Class 2), or flexible(Class 5) to BS 6360. Insulation: PE/XLPE Screen: (Overall Screen) (Individual Screen + Overall Screen) (Overall Screen + Steel Wire Armour) (Individual Screen+ Overall Screen+Steel Wire Armour) Sheath Version: PVC/LSF/LSOH Pair Identification: a) Collectively screened cables: Color coded in accordance with Color Code as per BS5308 standard. b) Individually screened pairs: One white core and one black core in each pair. Pairs identified by numbered screen isolation tape.
Conductor: Plain annealed Fire barrier: Mica Tape Insulation: XLPE Filler: Polypropylene yarn Binder Tape: Polypropylene sheath : LSOH compound No. of Core Conductor Nominal Thickness of Insulation Nominal Thickness of Sheath Approx. Overall Diameter Approx. Weight Size No/Dia. of Wire Approx. Dia. mm2 No/mm mm mm mm mm kg/km 2 1.5 7/0.53CR 1.59 0.7 0.9 9.0 115 2.5 7/.067CR 2.01 0.8 1.0 10.5 160 4.0 7/0.85CR 2.55 0.8 1.1 12.0 220 3 1.5 7/0.53CR 1.59 0.7 1.0 10.0 140 2.5 7/0.67CR 2.01 0.8 1.1 11.5 195 4.0 7/0.85CR 2.55 0.8 1.1 12.5 265 4 1.5 7/0.53CR 1.59 0.7 1.0 11.0 170 2.5 7/0.67CR 2.01 0.8 1.1 12.5 240 4.0 7/0.85CR 2.55 0.8 1.2 14.0 335 . Note: CR = Circular stranded conductor .
Application 6181B is cord for use in machine tools and electrical appliances. Conductor Extra flexible copper conductor Insulation PE/XLPE insulation Core Single core and multi core conductor from 0.5-1000 mmsq Armouring: Armoured and unarmoured available Jacket PVC/LSOH/LSF.
Application: Power limited circuit, remote control, signaling, security systems, communications, intercom/P.A. systems, sound/audio, and nurse call. Conductor Material: Bare copper wire strands Insulation Material: PE/PVC Laying-up: Units Drain Wire: Solid bare copper Shield: Overall Al/Polyester foil shield Nylon Rip Cord: 150D Sheath Material: PVC/LSF/PE Sheath Color: As your request Shape: Circular in cross-section Voltage Rating: 300/500 voltage Temperature Rating: 75íµ Fire Performance Flame Propagation Test to IEC 60332 Part 1 and Part 3 Determination of the amount Halogen Acid Gas to IEC 60754 Part 1 Smoke Density Test to IEC 61034 Oxygen Index Test to BS 2863 or ISO 4589-2 Temperature Index Test to BS 2782 or ISO 4589-3 Fire Resistant Test to IEC 60331-24.
Standards: Generally BS6500 VDE0250 Conductor: Class 5 annealed copper conductors to BS6360 / VDE0295 Insulation: PVC Bedding: PVC Braiding: Tinned Copper Wire Braid (TCWB) Sheath: PVC (Type TM2 to BS7655) Voltage Rating: 300/500V Temperature rating: Flexing -15ípC to +70ípC Static -35ípC to +70ípC
Central loose tube cable contains one tube with 2 - 24 fibers, which is filled with water blocking gel. A water swelling tape is helically wrapped around the cable core. Either aramid yarn or fiber glass is wound around the tube to provide physical protection and tensile strength. The cable is jacketed with PE for water protection purpose. For direct burial, steel wire armour and corrugated steel tape armour are applied with an optional PE
Screen: (overall screen) (indiviudual screen + overall screen) (overall screen + steel wire armour) (individual screen+ overall screen+steel wire armour) Sheath version: pvc/lsf/lsoh
Conductor material: solid plain annealed copper referred to bs6360 Insulation material: cellular high density polyethylene Laying-up: pairs; units Wrapping: polyester tape Filler: petrolatum jelly filled Screen: aluminium foil with overlapping Bedding: polyethylene
Applications: Long distance telephone, catv, data communications. Installations: Installed in duct, self supporting (figure 8 self supporting or adss all dielectric self supporting) and direct Burial (with armouring). Construction: The cable consists of a single tube containing 2 up to 24 fibers, which is filled with water-blocking gel. When the Cable contains more than 12 fibers, they are divided in two groups. A colored thread identifies each group. Physical Protection and tensile strength are provided by aramid yarn or fiberglass wound around the tube. Either pe or lszh Jacket can be used. A ripcord is located under the jacket to facilitate jacket removal. Technical parameters: Maximum transmission distance: 6km (single mode); 0.3km (multimode) Maximum pulling load: 1500n (short term installation); 900n (long term installation) Maximum compressive load: 3000n (3.3mm loose tube diameter); 5000n (4.5mm loose tube diameter) Twist (torsion length): 125 x overall diameter Working temperature: -20íµ ~ +70íµ (pe sheath) Storage temperature: -40íµ ~ +70íµ (pe sheath) Product highlights: Small diameter and light weight. Through the control of the fiber exceed length which is the key technology in optical fiber manufacture, the fiber Cable can achieve better pulling load and operating temperature. Tube materials are water resistant and can sustain high tension. Being filled with special water-blocking gel, the Tube can provide water protection for the fibers inside the tube. Compact construction of the fiber cores can prevent the fiber to shrink back. This can sustain higher tensile stress And achieve better flexibility. íewide operating temperature range. Roll, box, drum
í= Applications: Short and medium distance, indoor and protected environments. Offered as a riser, plenum, or general purpose cable, it is used for interconnection of distribution boxes, or the distribution boxes and customer equipments, and between floors. í= Installations: Installed along the wall, the roof, interlayer, canal and indoor. í= Construction: The cable contains 4 to 72 fibers individually buffered to 0.9 mm in a tight or semi tight construction and coded. The cable structure depends on the number of fibers: The 4 to 12 fiber cables contain individual fibers without sub-units,In the 16 to 72 fiber cables the fibers are grouped in the sub-units. In the 4 to 12 fiber cables, the individual fibers are stranded and protected by aramid yarn and a PVC or LSZH jacket. In the 16 to 72 fiber cables, the fibers are grouped into sub-units which are laid helically along the cable axis. Each sub-unit contains 4 to 6 fibers, aramid yarn and a PVC or LSZH jacket. The 72 fiber cable consists of twelve sub-units, nine of them are stranded around a central element made of 3 sub-units. í=Technical Parameters: íe Maximum Transmission Distance: 6km (Single Mode); 0.3km (Multimode) íe Maximum Pulling Load: 100N(Short Term Installation);60N(Long Term Installation) íe Minimum Bending Radius: Short Term Installation: 20 x Overall Diameter Long Term Installation: 10 x Overall Diameter (Non-Armoured); 20 x Overall Diameter (Armoured) íe Twist (Torsion Length): 125 x Overall Diameter. íe Working Temperature: -10íµ ~ +70íµ (PE sheath) íe Storage Temperature: -20íµ ~ +70íµ (PE sheath) í= Product Highlights: íe Small diameter and light weight. íe The high tension characteristics of the aramid yarn serving as strength member can offer good stability in the transmission performance. íe Compact and flexible construction are especially suitable for indoor installations. íe Tight Buffer fibers are made from fiber rods with good linearity and low extruding output. By careful calibration of the vacuum pumping equipment, the uniformity of the outer diameter of the tight buffer fibers can be easily achieved with excellent strip ability. íe LSZH jackets can be offered for indoor application for which flame retardancy is required. íe Cutting edge production equipment, good quality materials and optimized process ensure low induced attenuation within the operating temperature range. íe Fiber geometry are strictly monitored to ensure superior transmission performance. roll,box,drum
Applications: Long distance outside telephone, catv, data, communications. Installations: Installed in duct, self supporting (figure 8 self supporting or adss all dielectric self supporting) and direct burial (with armoring). Construction: The cable consists of 5 to 36 elements stranded in up to 3 layers around a central strength member and bound in a Jacket. The elements are usually fiber containing tubes. However, fillers are also used, when needed to preserve cable Geometry. Two to twelve color coded fibers are loosely laid in each tubes filled with water-blocking gel. Technical parameters: Maximum transmission distance: 6km (single mode); 0.3km (multimode) Maximum pulling load: 1500-2700 n (short term installation); 900-1500n (long term installation) Minimum bending radius: Short term installation: 20 x overall diameter Long term installation: 10 x overall diameter (non armored); 20 x overall diameter (armored) Twist (torsion length): 125 x overall diameter Working temperature: -40íµ ~ +70íµ (pe sheath) Storage temperature: -50íµ ~ +70íµ (pe sheath) Product highlights: All the fiber containing tubes are placed in concentric layers around the central member; through the control of The twist length, the fiber cable can achieve better pulling load and operating temperature. Tube materials are water resistant and can sustain high tension. Being filled with special water-blocking gel, the Tube can provide water protection for the fibers inside the tube. Central member, which is usually either made of dielectric frp, or solid/ stranded steel coated with polyethylene, Are placed at the centre of the cables. Roll, box, drum
Applications: 10base-t, 100base-t4, 100base-tx, 100base-vg-anylan, 155mbps atm, 622mbps atm Working frequency: 1-100mhz Technical parameters: Characteristic impedance: 100ía15ª+ Nominal velocity of propagation(nvp): 69% Maximum dc resistance: 9.38ª+/100m Maximum mutual capacitance: 5.6 nf/100m Maximum capacitance unbalance: 330 pf/100m Maximum resistance unbalance: 5% Maximum propagation delay skew: 30 ns/100m Maximum propagation delay: 536 ns/100m 100 mhz Minimum bending radius: 10 x overall diameter Voltage rating: 60v rms Maximum pulling load: 80n Working temperature: -20 íµ ~ +60íµ Storage temperature: -5íµ ~ + 50íµ Flame retardancy: ul 1581 (cm jacket); ul 1666 (cmr jacket); ul 910 (cmp jacket); iec 60332-1 (frpvc & lszh jacket); iec 60332-1 & iec 60332-3c (lsfroh jacket) Product highlights: Provide excellent bandwidth beyond 100 mhz. Designed for use in data and voice backbone application. Meet the strict flame retardancy and environmental requirements in europe and us. Easily identifiable color code for ease of installation. Transmission properties: Freq: 100 (mhz) Roll, box, drum
Ics (integrated circuits), resistors, capacitors and other electronic components, especially ic and capacitor.Distributor, inspection
Ladies garments like dresses, kaftan and T-shirts, contemporary fusion wear like tunics and harem pants, accessories like kaprice scarves and stoles .Export
N95 and surgical masks, niosh certified n95 respirators, n95, ffp22, ffp33 face masks, respirators and gloves, surgical masks; kn95 masks, fda and ce certified, iso 9001, respirators, yuwell ventilators.
PCB & PCBA .Manufacturer.