Paper, vinyl, polyamide, polyester, metal foil, PC, PET.
Non-inductive, dip coated, high moisture resistance. Good reputation in use with filtering, dc blocking coupling and general communication equipment. High reliable with its self-healing performance. Coated with epoxy resin for superior heat resistance. Operating temperature:-40c~+85c Rated voltage:100.250.400.630vdc Capacitance range:0.01~6.8uf Capacitance tolerance:+/-5%, +/-10%
Film capacitors Mylar polyester film capacitor---jfa series Metallized polyester film capacitor---jfb series Metallized polyester film capacitor (vac) ---jfc series Box type met polyester film capacito---jfd series r Mini met polyester film capacitor---jfe series Mini laser met polyester film capacitor---jff series Axial met polyester film capacitor---jfg series Polypropylene film capacitor---jfk series Met polypropylene film capacitor---jfl series Box type met polypropylene film capacitor---tbd X2 metallized polypropylene film capacitor---jfn series Series polypropylene fim capacitor---jfp series Box type double sided met polypropylene fim capacitor---jfq series Radial & axial polystyrene film capacitor---jfr series Motor starting capacitor---jfs series
Conductor: Plain annealed Fire barrier: Mica Tape Insulation: XLPE Filler: Polypropylene yarn Binder Tape: Polypropylene sheath : LSOH compound No. of Core Conductor Nominal Thickness of Insulation Nominal Thickness of Sheath Approx. Overall Diameter Approx. Weight Size No/Dia. of Wire Approx. Dia. mm2 No/mm mm mm mm mm kg/km 2 1.5 7/0.53CR 1.59 0.7 0.9 9.0 115 2.5 7/.067CR 2.01 0.8 1.0 10.5 160 4.0 7/0.85CR 2.55 0.8 1.1 12.0 220 3 1.5 7/0.53CR 1.59 0.7 1.0 10.0 140 2.5 7/0.67CR 2.01 0.8 1.1 11.5 195 4.0 7/0.85CR 2.55 0.8 1.1 12.5 265 4 1.5 7/0.53CR 1.59 0.7 1.0 11.0 170 2.5 7/0.67CR 2.01 0.8 1.1 12.5 240 4.0 7/0.85CR 2.55 0.8 1.2 14.0 335 . Note: CR = Circular stranded conductor .
Product Name:Picnic Bag Item No.:ML05008 Fabric: 600 deniel polyester green color Dimensions:30x28x42 cm 3x goblet 1x bottle opener 3x napkin 3x spoon/knife/fork 3x melamine plate 1x salt&pepper 1x cutting board
Product Name:Picnic Bag Item No.:ML05009 Fabric: 600 deniel polyester red color, with black color match lining. Dimensions:30x21x40 cm 4x goblet 1x bottle opener 4x napkin 4x spoon/knife/fork 4x melamine plate 2x salt&pepper 1x cutting board
Light polyester awnings, pvc awnings.
Conductor: Plain annealed Fire barrier: Mica Tape Insulation: XLPE Filler: Polypropylene yarn Binder Tape: Polypropylene Sheath : LSOH compound.
Product Name:Camping tent Item No.:ML00002 Size: 250X150X105cm Material:170T polyester 110g PE waterproof fiber glass tube dia 6.9mm Packing:1pc/polyester bag
Products Name: Sand Beach Chair Item No.:ML01008 Dimension:81x47x78cm Fabric: 600D polyester Tube:Aluminium 25mm Packing size:82x52x58cm Qty:6pcs
Central loose tube cable contains one tube with 2 - 24 fibers, which is filled with water blocking gel. A water swelling tape is helically wrapped around the cable core. Either aramid yarn or fiber glass is wound around the tube to provide physical protection and tensile strength. The cable is jacketed with PE for water protection purpose. For direct burial, steel wire armour and corrugated steel tape armour are applied with an optional PE
Conductor material: solid plain annealed copper referred to bs6360 Insulation material: cellular high density polyethylene Laying-up: pairs; units Wrapping: polyester tape Filler: petrolatum jelly filled Screen: aluminium foil with overlapping Bedding: polyethylene
í= Applications: Short and medium distance, indoor and protected environments. Offered as a riser, plenum, or general purpose cable, it is used for interconnection of distribution boxes, or the distribution boxes and customer equipments, and between floors. í= Installations: Installed along the wall, the roof, interlayer, canal and indoor. í= Construction: The cable contains 4 to 72 fibers individually buffered to 0.9 mm in a tight or semi tight construction and coded. The cable structure depends on the number of fibers: The 4 to 12 fiber cables contain individual fibers without sub-units,In the 16 to 72 fiber cables the fibers are grouped in the sub-units. In the 4 to 12 fiber cables, the individual fibers are stranded and protected by aramid yarn and a PVC or LSZH jacket. In the 16 to 72 fiber cables, the fibers are grouped into sub-units which are laid helically along the cable axis. Each sub-unit contains 4 to 6 fibers, aramid yarn and a PVC or LSZH jacket. The 72 fiber cable consists of twelve sub-units, nine of them are stranded around a central element made of 3 sub-units. í=Technical Parameters: íe Maximum Transmission Distance: 6km (Single Mode); 0.3km (Multimode) íe Maximum Pulling Load: 100N(Short Term Installation);60N(Long Term Installation) íe Minimum Bending Radius: Short Term Installation: 20 x Overall Diameter Long Term Installation: 10 x Overall Diameter (Non-Armoured); 20 x Overall Diameter (Armoured) íe Twist (Torsion Length): 125 x Overall Diameter. íe Working Temperature: -10íµ ~ +70íµ (PE sheath) íe Storage Temperature: -20íµ ~ +70íµ (PE sheath) í= Product Highlights: íe Small diameter and light weight. íe The high tension characteristics of the aramid yarn serving as strength member can offer good stability in the transmission performance. íe Compact and flexible construction are especially suitable for indoor installations. íe Tight Buffer fibers are made from fiber rods with good linearity and low extruding output. By careful calibration of the vacuum pumping equipment, the uniformity of the outer diameter of the tight buffer fibers can be easily achieved with excellent strip ability. íe LSZH jackets can be offered for indoor application for which flame retardancy is required. íe Cutting edge production equipment, good quality materials and optimized process ensure low induced attenuation within the operating temperature range. íe Fiber geometry are strictly monitored to ensure superior transmission performance. roll,box,drum
Reference Standard: CW1198 Application: This cable is used for communication and telephone systems, distribution cabling and direct buried. Conductor Material: Solid plain annealed copper referred to BS6360 Insulation Material: Cellular High Density Polyethylene Laying-up: Pairs; Units Wrapping: Polyester Tape Filler: Petrolatum Jelly filled Screen: Aluminum foil with overlapping Bedding: Polyethylene.
Applications: Long distance telephone, catv, data communications. Installations: Installed in duct, self supporting (figure 8 self supporting or adss all dielectric self supporting) and direct Burial (with armouring). Construction: The cable consists of a single tube containing 2 up to 24 fibers, which is filled with water-blocking gel. When the Cable contains more than 12 fibers, they are divided in two groups. A colored thread identifies each group. Physical Protection and tensile strength are provided by aramid yarn or fiberglass wound around the tube. Either pe or lszh Jacket can be used. A ripcord is located under the jacket to facilitate jacket removal. Technical parameters: Maximum transmission distance: 6km (single mode); 0.3km (multimode) Maximum pulling load: 1500n (short term installation); 900n (long term installation) Maximum compressive load: 3000n (3.3mm loose tube diameter); 5000n (4.5mm loose tube diameter) Twist (torsion length): 125 x overall diameter Working temperature: -20íµ ~ +70íµ (pe sheath) Storage temperature: -40íµ ~ +70íµ (pe sheath) Product highlights: Small diameter and light weight. Through the control of the fiber exceed length which is the key technology in optical fiber manufacture, the fiber Cable can achieve better pulling load and operating temperature. Tube materials are water resistant and can sustain high tension. Being filled with special water-blocking gel, the Tube can provide water protection for the fibers inside the tube. Compact construction of the fiber cores can prevent the fiber to shrink back. This can sustain higher tensile stress And achieve better flexibility. íewide operating temperature range. Roll, box, drum
Application: Power limited circuit, remote control, signaling, security systems, communications, intercom/P.A. systems, sound/audio, and nurse call. Conductor Material: Bare copper wire strands Insulation Material: PE/PVC Laying-up: Units Drain Wire: Solid bare copper Shield: Overall Al/Polyester foil shield Nylon Rip Cord: 150D Sheath Material: PVC/LSF/PE Sheath Color: As your request Shape: Circular in cross-section Voltage Rating: 300/500 voltage Temperature Rating: 75íµ Fire Performance Flame Propagation Test to IEC 60332 Part 1 and Part 3 Determination of the amount Halogen Acid Gas to IEC 60754 Part 1 Smoke Density Test to IEC 61034 Oxygen Index Test to BS 2863 or ISO 4589-2 Temperature Index Test to BS 2782 or ISO 4589-3 Fire Resistant Test to IEC 60331-24.