-Aesthetic appearance with flawless , monolithic side and front surfaces . -Suitable for decorations, side and front surfaces allows to implement graphic design, pictures and patterns on panel radiator. -Wide product range for different lifestyles and architectural implementations. -Integrated side and front panels are not allows dust through the radiator and provides easy cleaning. -Straight and striped alternative models. -Type L wall hanger to provide practical and easy assembly.( â??Jâ?? console and floor mounting parts are available on request equivalent itâ??s price). -Accessory set consisting of screws, dowels and purge valve pipe stopper -Protection (for babies )with low temperature on front surface. -Optional Ventil and Central Ventil models options( 6 connections hole) -Optional ventil production with ventil plugs and 8 connection hole. A wide range of product choice with 7 types (10,11,20,21,22,30,33 ) , 5 heights ( 300,400, 500, 600, 900mm) , 27 lengths ( from 400-500-600-700 to 3000mm)and 2 models ( 4 holes and 6 holes )
-production ventil plug with six connections provides ease to assembly and heat saving. -Optional Ventil plugs production with 8 perforated connection. -Advanced user control and energy saving for comfortable warming with use of thermostatic valve. -Sub connection possibility that hides installation pipes from wall and floor -Possibility to provide thermostatic ventil and thermostatic head. -Possibility to produce Ventil plugs as gear -For stock and usage flexibility, assembly by J type fixing brackets (Alternative bracket types for wall-mounting and floor mounting assembly are optional) - The model's Ventil plugs are on bottom-mid, its distance of all height, type and length are constant and it gives advantage for placement. -Central connection model provides cross-link functionality to increase efficiency of radiator. Central connection model allows to change with different measures without removing installation. -Termo VKR ventil plugs are produced as standard and located at right bottom of panels. -TERMO VKL ventil plugs are produced as standard and located at left bottom of panels. -Termo VK ventil plugs are produced as standard and can be use as left and right as location. -Termo VK-M ventil plugs are connected as bottom and mid center.
Smoke and smell prevention with the high efficiency (minimum smell loss & efficiency loss) World-Famous TRION electrostatic filters Emergency stop button, Control panels which have dirt measurement sensors, provide speed control Smell proof high efficient carbon filters with cylindrical cartridges which can be adjustable due to needed flow rate -
Eurovent certified In the range of 0- 100.000 mâ³/h air flow rate High energy efficiency and manufacturing quality Improved air quality Low noise levels Customer satisfaction-oriented, well-educated technical support -
Ceiling type heat recovery units 8 different models In the range of 500-5.000 mâ³/h air flow rate High energy efficiency & air quality User friendly control panel Fast service and technical support Availability of heater with water or electricity Communication with bms (compatible with the automation) -
Our fire damper (bfd-cs) with en 1366-2:1999 eis 120 certification and ce market. E: integrity I:insulation S:smoke leakage 120 â?? value in minutes of eis classification periods (120 minutes resistance). Fä±re damper is a part of fire wall and it must be closed during fire.Fire dampers should have thermal sensors. The damper has special gasket providing tightness between wall and casing, intumescent gasket, 30 mm thick calsium silicate board, high temprature resistant silicone. -
70 kg/m3 density, 20 mm thickness fire rated rockwool is used between the blade walls. Fire dampers are used for the purpose of preventing the fire and smoke from diffusing to other places with air ducts in building ventilation systems. The fusible link mechanism that is presented at the damper provides the blade in the damper to close by driving with the return spring when it reaches at 72°C and prevents the fire from diffusing to other places. Also, it can be controlled with servomotor automation system, as well. The fusible link is fixed to the damper on the face where damper handle is presented in such a way that it can be replaced easily.
Rectangular sound absorbers and Round sound absorbers are used for providing the absorbtion of the sound occuring in air conditioning and ventilation systems, the filling materials inside the splitters are 2 pieces of glasswools that have one surface coated with fiberglass with 50 mm thickness and 70 Class.Rectangular sound absorber whose splitter thickness is 100 mm and 200 mm.Round sound absorber whose splitter thickness is 100 mm and 200 mm.
Air Handling Units with Direct Expansion Coils No need of any chiller and/or hot water boiler Capable of air conditioning with only a VRF outer unit High COP values, Low initial investment costs Easy and fast solutions for small and medium sized facilities
Channel Type Fans Highly efficient rectangle channel type fan In the range of 950-9.500 m³/h air flow rate Metal sheet with the durability of corrosion Low noise levels Ease of installation Speed control -
General information Air to water heat pipe heat exchanger is mainly to heat water using the hot air from heat recovery, it can be used for domestic water, water for boilers or production process. The exchanger is constructed using a partition in the middle to separate the exchanger, both sides are independently sealed. A single heat pipe can be replaced. While working the hot air flows from one side to the other side, the heat pipe absorbs heat. Meanwhile, cold water flows from the reverse side, the heat pipe releases heat, thus heating the cold water from the reverse side. The outlet temperature is not lower than dew temperature. Field of application -feed drying -cereals and oil processing -chemical industry Specification Advantage: -high heat recovery efficiency -seldom temperature difference, fast heat starting, good isothermal -the speciality of the heat pipe results in a high wall temperature, exhaust gas temperature can be reduced without reaching the acid dew point, avoid the corrosion of the equipment.
In ruiming assembly special aluminum foil phenolic composite duct system, design color embossed double-sided coating of aluminum foil processing by zrop, a clear pattern, the overall appearance, comfortable and high strength core material, embossing processing, fine strong texture, can also spray harmonic color required, full color matching with the occasion. Widely used in supermarkets, hypermarkets and other occasions with the.
For Heating and Cooling Contractors the use of special service pages might include Furnaces repaired and Installed, Water Heaters, Chimney Inspection, Air Conditioning Units Repaired Installed and Replaced etc. This is a lucrative service to offer and if someone is searching, in your area, for a reliable professional Heating and Air Conditioning company you want to be the first option they see.
Robust Design. Designed according to Indian conditions. Certified components only used. CNC bended pipes used only, no elbows used.
Lsg-3000 moving detector goniophotometer completely meets lm-79 clause 9.3.1 requirement. The lsg-3000 is an automatic light distribution intensity 3d curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, led or hid luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires. Measurement: Luminous intensity data, luminous intensity distribution, zonal luminous flux, luminaries efficiency, luminance distribution, coefficient of utilization, luminance limitation curves glare, maximum ratio of distance to height, equal illuminance diagrams, curves of luminaires vs lighting area, lsocandela diagrams, efficient luminescence angle etc. Features: many national patents pending on hardware and software. cie class a & constant temperature photo detector (class l detector can be optional). high degree of intelligent and test function is complete. the rotation motor is from japan mitsubishi motors and it uses germanic angle decode system, it will help smoothly and high accuracy rotation. It is very stable when start and stop. the working principles are according to iesna and cie. This instrument is specially recommended by lm-75, lm-79 and cie121-1996. with some optional instruments, it has good expanding functions the position and working state remain the same as it is under working. special collimation device with laser cross line, conveniently and accurately fix the position of the tested luminaries. Wooden case
Emi-9ka is an automatic emi receiver. It is a main test system for emi (electro magnetic interference) testing. The emi-9ka is produced by the full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for the emi test system, it solved the instrument self-emi problem. The test results are according to the international format test report. The emi test system emi-9ka fully meets cisprl6-1, gb17743, fcc, en55015 and en55022. Specification: • detection frequency range: 9khz~30mhz ( emi-9ka) or 9khz~300mhz ( emi-9kb) • frequency stability: 1x 10-6 • frequency resolution: (9khz~150khz) 30hz; (150khz~30mhz) 1khz • test tolerance: ±2 db • measure and detection method: pk, qp and av range from 20dbµv to 140dbµv • test time: setting by customers • frequency scanning step length: 20hz~2mhz • sweep bandwidth: 200hz; 9khz; 120khz
Introduction: Esd simulator (electrostatic discharge generator or electrostatic gun) is in full compliance with iec 61000-4-2, en61000-4-2, iso10605, gb/t17626.2, gb/t17215.301 and gb/t17215.322. The esd generator is designed for the assessment of electrical and electronic equipment to withstand esd performance. Esd61000-2/esd61000-2a has lcd display in both english and chinese, they equipped with an infrared remote control which can allow you do the test in some special place. Specifications: Product model Esd61000-2 Esd61000-2a Output voltage 0.1~20kv±5% 0.1~30kv±5% Polarity Positive/negative Positive/negative Energy storage capacitance 150pf±10% (replaceable) 150pf±10% (replaceable) Discharge resistor 330o±5% (replaceable) 330o±5% (replaceable) Current rise time 0.6~1ns 0.6~1ns Testing functions Single, count, 20pps, air, contact, iec level Single, count, 20pps, air, contact, iec level Trigger mode Manual/auto Manual/auto Numbers of discharge 1~9999 1~9999 Repetition 0.05s~99.99s 0.05s~99.99s Working power Ac220v(option 110v)±10%, 50/60hz Ac220v(option 110v)±10%, 50/60hz Touch screen with super big lcd and built-in windows ce Calibrate report: Output voltage (kv) First peak current (a) Current at 30ns (a) Current at 60ns (a) Rise time (ns) 2 7.29 4.10 2.20 0.93 4 15.40 7.90 4.30 0.97 6 23.20 12.10 6.50 0.97 8 29.40 16.20 9.30 0.89 -2 7.39 3.50 2.30 0.92 -4 15.50 7.70 4.30 0.89 -6 23.40 11.90 6.30 0.90 -8 31.80 16.10 8.20 0.90 Note: metal holder needs extra cost.
1. Introduction to 10 Ton Water Cooled Chiller Water-cooled chillers are essential equipment in various industrial sectors, providing efficient and reliable cooling solutions for large-scale applications. A 10-ton water-cooled chiller refers to a cooling system capable of removing 10 tons of heat per hour from a process or space. This technology is vital in industries requiring precise temperature control, such as food processing, pharmaceuticals, plastics, and HVAC systems. In this article, we will explore the critical features of a 10-ton water-cooled chiller, including its components, applications, advantages, and installation requirements. We will also address the factors to consider when selecting a chiller and discuss maintenance tips to ensure optimal performance and longevity. 2. Understanding the Basics of a 10 Ton Water Cooled Chiller 2.1 Definition and Capacity of a 10-Ton Chiller A chiller's "tonnage" refers to its cooling capacity, with one ton equal to the ability to remove 12,000 BTUs (British Thermal Units) of heat per hour. Therefore, a 10-ton water-cooled chiller can remove 120,000 BTUs of heat per hour. This capacity makes it suitable for medium to large-scale cooling needs in various industrial settings. 2.2 How Water-Cooled Chillers Work Water-cooled chillers function by utilizing water to absorb heat from a process or environment. The chiller's refrigerant system circulates through a compressor, evaporator, condenser, and expansion valve. The evaporator cools the water, which is then circulated through the system to absorb heat. The heated water is sent to the cooling tower, where the heat is dissipated into the atmosphere, and the cycle repeats.
Used air conditioner G/L, SAMSUNG, Brand good condition , BTU 8000, ,12500 , 14500 , 17000 , 20000 , PRICE UP SINCE $160
Kendall is a supplier of air-cooled two-stage piston condensing units. These units are designed to provide reliable and efficient cooling for a variety of applications, including commercial refrigeration, HVAC systems, and industrial processes. Air-cooled two-stage piston condensing units are highly efficient and reliable refrigeration systems used in a variety of applications. The cost of these units can vary depending on several factors, but they offer significant advantages over other types of refrigeration systems. FAQs 1. What is an air-cooled two-stage piston condensing unit? An air-cooled two-stage piston condensing unit is a refrigeration system that uses two compression stages for improved efficiency and cooling capacity. It features air-cooled condensers and piston compressors, ideal for low-temperature applications like freezing and industrial refrigeration. 2. What are the advantages of using an air-cooled two-stage piston condensing unit? Advantages of using an air-cooled two-stage piston condensing unit include higher energy efficiency, enhanced cooling capacity, and reliable performance in low-temperature applications. These units offer better temperature control, and reduced energy consumption, and are suitable for industrial and commercial refrigeration needs. They are highly efficient and reliable, with lower operating costs and longer service life. They also require less maintenance and are easier to install than water-cooled systems. 3. What applications are air-cooled two-stage piston condensing units used for? Air-cooled two-stage piston condensing units are used in applications such as industrial refrigeration, cold storage, food processing, and low-temperature freezing. They are ideal for environments requiring precise temperature control and efficient cooling, such as supermarkets, warehouses, and pharmaceutical storage facilities. 4. How much do air-cooled two-stage piston condensing units cost? The cost of an air-cooled two-stage piston condensing unit can vary depending on several factors, such as the size of the unit, the brand, and the features. Generally, these units range in price from a few thousand dollars to tens of thousands of dollars.