Power & distribution transformers.
Toroidal transformer, EL transformer, R type transformer.
Transformer.
Electric transformer.
Distribution and power transformers.
Current transformer.
Distribution transformer, power transformer.
Current transformers.
Transformer.
Electric transformer.
Transformer.
Transformer.
Transformer.
Transformer cores.
TRANSFORMER : ALL TYPE : Dry Type/Air Cooled, Oil Cooled, Water. BRAND: SCHNEIDER ELECTRIC AND ALL OTHER BRAND AVAILABLE. we are trader of Distribution Transformer and supply all over world. We have 20 Years Experiance Technical team for Desining and Winding of Diffrent types of Transformer. We have 15 Years Experiance Technical Team for Testing of Transformers. We can supply transformer up to 33kV and up to 5000kVA.
GE TRANSFORMER PROTECTION RELAY MODEL :- MUITILIN T60-N11-AKH-F8L-H6N-M8L-P6P U6P-W6;
'ALSTOM' Protection Relay MODEL NO:- P64392AE6M0060M;
GE TRANSFORMER PROTECTION RELAY The T60 Transformer Protection System is part of the Universal Relay (UR) series of products. It is a microprocessor-based relay for protection of small, medium, and large three-phase power transformers. The relay can be configured for a maximum of six three-phase current inputs and six ground current inputs, and can satisfy applications with transformer windings connected between two breakers, such as in a ring bus or in breaker-and-a-half configurations. The T60 performs magnitude and phase shift compensation internally, eliminating requirements for external CT connections and auxiliary CTs.
ALSTOM GBCDG61EG020SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG020SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Contacts 3M S/R Output contacts 2M S/R C.T.Secondary 1 amps Frequency 50 Hz Burden 3 VA Operating time 3 secs Current setting - E/F 0.1 to 0.4 amps High set - O/C Setting 4 to 16 amps High set - E/F Setting 1 to 4 amps High set/High set contact CAG 13 / 2M S/R Name plate RFG9126 901 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
GBCDG61EG031SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG031SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Contacts 3M S/R Output contacts 2M S/R C.T.Secondary 5 amps Frequency 50 Hz Burden 3 VA Operating time 1.3 secs Current setting - E/F 1 to 4 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 10 to 40 amps High set/High set contact CAG 13 / 2M S/R Name plate RFG9125 904 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1