Power supply As request
Wise - transformer Wise trnsformers are built according to all ce rules , are ferro-magnetic built , balast type , is a classe i product . 20 units pack , eacch transformer 0, 800gr , palets of 1500 transformers
20-60w transformer Tp708 20-60w Watt (w) Voltage (v) output Ac(v) lifetime (hrs) dimension (mm) L*d*h carton-box (100pcs)cm n.W./g.W. (kg) 20-60 110-130 12 fª20000 78*42*31 39.5*24*18.5 9/10 Carton
Transformer Tp745a 20-105w Watt(w) Input v) output Ac(v) lifetime (hrs) dimension (mm) L*d*h carton-box (100pcs)cm n.W./g.W. (kg) 20-60 220-240 12 fª20000 120*42*32 51*24.5*20.5 11/12 Carton
Transformer
Cooperation Ningbo yinzhou huayuan electric & machine industry co., ltd. Is located in ningbo city which is at the middle part of china's coastline and south flank of the yangtze river delta, bordering on shanghai. The traffic is very convenient that is 30 km away from ningbo port, 15 km away from ningbo airport. It is the professional manufacturer, supplier and exporter of precision electrical and mechanical machine and parts, electric power instrument, wind-solar products, industrial wiring. It is a developing tech conglomerate of designing, manufacturing, trading , importing and exporting. All products had completely pass through the iso9000 quality system and obtain the manufacturing certification awarded by state bureau of quality and technical supervision, eqc&ccc award by chinese quality authentication center, testing certification awarded by nation high-voltage testing center. Up to now, all kinds of products have been distributed all over the country and widely used in the key state projects and large-scale construction projects. Some of products have been exported to more than ten asian and european countries and regions We will provide defect-free products and services on time for our customers and each other. We will require the same from our suppliers. We will fully understand the requirements of our jobs and are committed to doing it right the first time as a way of working. 1. We can do the 5 bests: best price , best product, best quality, best technology, best service for you; 2. We can be your representative and office in china 3. We can combined with you to sell chinese product and technology to the world and your product to china; 4. We can supply all the parts for you to assembly the whole machine, all the machines for you to set a systems; 5. We can support you to join the tender of the engineering project with document and technology.
Transformer
Ferrite cores 1 mnzn ferrite cores for switch power transformers 2 mnzn ferrite cores for crt monitor transformers 3 high-magnetic-conductivity mnzn ferrite cores for pulsed transformers, broadband transformers, filters, and inductance 4 mnzn ferrite core for emi resistant applications 5 nizn ferrite cores 6 nizn ferrite cores for emi resistant applications
6kv-110kv transformer 1)6kv-35kv sc9, sg10 series insulation dry power transformer 2)6kv-110kv s9, s10, s11 series oil immersed transformer 3)6kv-35kv dz9 series oiled immersed single-phase transformer 4)6kv-35kv the single-phase oil-filled pole-mounted distribution transformers 5)6-40.5kv yb, zbw1, zbw3, jbw series power combined substation Export packing
Low, medium and high voltage transformers 110kV Class Power Transformers General The110kV class low loss transformers are developed by Huapengour workshop through years of service experience and careful analysis of the advantages and disadvantages of the transformers of different manufacturers, both domestic and abroad, and are featured by low loss, low partial discharge, low noise, high strength against short circuit, and high reliability in service. Its outstanding performance has won high reputation throughout China, and the world, and are highly appreciated by experts of the circle. Transformers can be made with welded tank cover and/or flange , Thus obviated from the necessity of lifting out the active part for inspection after arrival on site. Partial discharge level: apparent discharge < 80pC at 1.5 times rated voltage. Noise level : below 58 dB for transformers 63MVA and below with AN cooling Losses: no-load loss 30% lower than specified by GB/T 6451-1995 Reliability: no damage or oil leakage have been found in transformers in service up to the present Short-circuit withstand capability: Our SZ9-31500/110,SSZ-50000/110 transformers successfully passed short-circuit test in National Transformer Quality Inspecting and Testing Center, and in CESI Laboratory of Italy. Winding 1. Partially interleaved continuous winding is used for HV winding to improve its behavior under lightning impulse, because of its more uniform voltage distribution. 2. All the spacers and vertical strips are rounded at corners, in order to obtain a more reliable insulation structure. 3. Zig-Zag directional flow is provided inside the windings, so that all parts of the windings are better cooled, resulting in lower winding temperature rise, and specifically lower hot-spot temperature, thus the insulation life of the transformer is prolonged. 4. Separate regulating windings are provided for both the 110kV high voltage and the 35kV medium voltage side, so that a more balanced ampere-turn is obtained in spite of tap-changing, the short-circuit withstand capability is thus promoted. Radially, the windings of a phase assembly are tight-fit, little space is left between the core and the low-voltage cylinder, and between the windings. All the vertical strips and cylinders are thoroughly dried before assembly, so that a tight phase assembly can be finally obtained. Core 1. High permeability grain oriented high quality cold-rolled sheets are used for the fabrication of core. The sheets are cut on automatic cutting line made by Georg Co. of Germany or Soenen Co. of Belgium. The burrs are controlled within 0.02mm. 2. The core is stacked without stacking the upper yoke, the upper yoke sheets are placed into position after the winding blocks are mounted on the core. The joints of the core sheets are mitred 45fpjoint with step-lap. The stacked core is pressed under even pressure and the edge of the sheets are painted with epoxy resin, so that a straight, robust, integral structure is obtained, helping to reduce core loss and noise. 3. Wooden strips are driven into the space between core and LV cylinder. The yoke is kept tightened by epoxy-resin impregnated glass tape, while the lower yoke is pressed against the wall of the lower tank through threaded bolts. The active part of the transformer is in addition kept in position by devices at three places between the upper yoke and the tank cover in such a way that the active part cannot be displaced during transportation.
Transformer Grade-h insulation amorphous alloy transformer 10kv-35kv 30kva-2500kva This product is another novelty developed by employing proven techniques from both both united state and china on the basis of our company's successful production of model sg10 grade-h insulation unrestricted venting dry-type transformer. It lowers the no-load loss and open-circuit loss intensively, and is of superior performance, thus it is currently the state-of-the-art dry-type transformer in the world. This product is safe, reliable, environment friendly and energy saving, and can go deep into the load center and is applicable to modern city's high-density and heavy-load developmental needs.
Transformer Grade-h insulation amorphous alloy transformer 10kv-35kv 30kva-2500kva This product is another novelty developed by employing proven techniques from both both united state and china on the basis of our company's successful production of model sg10 grade-h insulation unrestricted venting dry-type transformer. It lowers the no-load loss and open-circuit loss intensively, and is of superior performance, thus it is currently the state-of-the-art dry-type transformer in the world. This product is safe, reliable, environment friendly and energy saving, and can go deep into the load center and is applicable to modern city's high-density and heavy-load developmental needs. High temperature resistant liquid-immersed transformer 10kv 30kva-3150kva 35kv 50kva-31500kva
Transformer bobbins Injected phenolic material and inserted pins 39x34x29cm about 9kgs
Transformer bobbins Made from Phenolic, PBT, Rynite or Nylin
Electrical And Safety And Tools Item Supply.
Ic Chips Of Ti.
Home appliances parts , and services of airconditoner, washing machine, microwave oven, solar, heatpump, fridge and freezer, nashik maharashtra.Home appliances repair services nashik
Oxygen Generator Plant, Nitrogen Generator Plant, Air Handling Unit, Gobargas, Biogas Generator Plant, Engineering Projects.
Rc model like car, botat, flight, gun battery, rechargeable lipo battery, lipo battery charger, virtual flybarless system, battery adopter, brushless motor.
Product description Insulating boots and gloves withstand voltage device is a power frequency power supply with low voltage working voltage of 220V/50Hz for insulating boots and gloves. According to the principle of electromagnetic induction, the input voltage is changed to the minimum value required for the test. high pressure. Insulating boots (gloves) withstand voltage test device generally consists of a special dedicated test box, an intelligent power frequency withstand voltage console, and a power frequency withstand voltage test transformer. A special water tank can be customized according to needs to test 6-8 insulated boots or 6 insulated gloves at a time, and display the leakage current of the insulated boots or insulated gloves at the same time. The intelligent power frequency withstand voltage console is equipped with overcurrent protection and zero protection. Time protection and alarm function. The preventive voltage resistance test device for insulating boots and gloves is a special product developed and produced according to the needs of users according to the test procedures of insulating boots (gloves). The selection has an automatic boost (buck) function, automatically reads the leakage current of each test product, the whole process is automatically completed, and the test data is automatically printed, which effectively solves the previous non-standard test methods, thereby simplifying .Simplifies the test procedure and improves the test speed. More reliable identification of parameters such as leakage current and power frequency withstand voltage of insulating boots (gloves). To ensure the safety of test personnel, it is an ideal pre-treatment of insulating boots (gloves) to protect power frequency withstand voltage test equipment. Technical Parameters Input voltage AC220V 50 Hz Output voltage 0~30kV Capacity 3kVA Test number 3 pairs each time Quality Gloves (insulating boots) test car: 80kg; power frequency withstand voltage test bench: 70kg